GAS PIPING

Gas piping shall be of such size and so installed as
to provide a supply of gas sufficient to meet the
full gas input of the appliance. If the appliance is
to be connected to existing piping, it shall be
checked to determine if it has adequate capacity.
Joint compound (pipe dope) shall be used
sparingly and only on the male threads of the pipe
joints. Such compounds shall be resistant to the
action of L.P. gases. WARNING: Any loose dirt
or metal particles which are allowed to enter the
gas lines on this appliance will damage the valve
and affect its operation. When installing this
appliance, all pipe and fittings must be free from
all internal loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with
each charbroiler. It should be connected to the
inlet pipe at the rear of the unit. The gas supply is
then connected to it. It is shipped set for 6" water
column manifold pressure for use with natural
gas. Allow 6" clearance from back of unit to wall
fro servicing and installation.

CONNECTING GAS SUPPLY LINE

The gas inlet of the charbroiler is sealed at the
factory to prevent entry of dirt. Do not remove
this seal until the actual connection is made to the
gas supply line.

MANUAL SHUT OFF VALVE

A manual shut off valve should be installed
upstream from the manifold and within six feet of
the charbroiler.

PROPANE GAS

This charbroiler is equipped with fixed orifice
hoods and is shipped from the factory for use
with natural gas. To convert to propane gas,
install the burner orifice hoods supplied behind
the front panel as follows:
1. Remove grill, radiants and burners.
2. Remove the burner orifice hoods and install

the orifice hoods supplied.

3. Replace the burners, radiants, and grill.
4. Set manifold pressure to (10) inch water
column. A 1/8" pipe plug on the burner manifold
can be removed for attaching a pressure gauge.

Remove the slotted, or hex-threaded plug from
the pressure regulator.  Invert the plug and
re-install.  The letters "LP" should now be visible
on the plug.  The regulator is now set for 10"
(25.4 cm) water column.

CHECKING FOR GAS LEAKS

Soap and water solution or other material
acceptable for the purpose, shall be used in
locating gas leakage. Matches, candle flame or
other sources of ignition shall not be used for this
purpose. Check entire piping system for leaks.

PILOT LIGHTING INSTRUCTIONS

The charbroiler is equipped with standing pilots,
and should be lit immediately after the gas is
turned on.
1. Turn off main valve to unit and wait 5 minutes

to clear gas.

2. Turn off all knobs and pilot valves.
3. Turn on main valve and light all pilots.
4. Turn burner knobs to desired setting.
5. To turn burners off, turn knobs off.

SHUTTING DOWN INSTRUCTIONS

1. Turn the burner valve knobs to the off position

to turn burners off.

PILOT LIGHT REGULATION

The pilot lights on this broiler have been turned
off at the factory. Adjust pilot light flames as small
as possible, but high enough to light burner
immediately when burner valve is turned on high.

BURNER OPERATION

To ignite burners, turn burner valve knob to "HI"
position. Each burner is controlled by an
individual high-low, on-off valve. An infinite
number of broiling temperatures may be
obtained by turning the burner valve knob to any
position between high and low.

BURNER ADJUSTMENT

1. Turn burner valve knob to "HI" position.
2. Slowly decrease openings of air shutters to

give a soft blue flame having luminous tips,
then slowly increase openings to a point where
the yellow tips disappear and a hard blue flame
is obtained.

Содержание 6015CB

Страница 1: ...al Inc 10 Sunnen Drive St Louis MO 63143 Phone 314 781 2777 FAX 314 781 3636 Installation and Operating Instructions STAR MAX GAS CHARBROILER MODELS 6015CB 6024CB 6036CB 6115RCB 6124RCB and 6136RCB Model 6024CB 2M Y7198 Rev F 6 28 00 ...

Страница 2: ...l shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PS...

Страница 3: ...ll the orifice hoods supplied 3 Replace the burners radiants and grill 4 Set manifold pressure to 10 inch water column A 1 8 pipe plug on the burner manifold can be removed for attaching a pressure gauge Remove the slotted or hex threaded plug from the pressure regulator Invert the plug and re install The letters LP should now be visible on the plug The regulator is now set for 10 25 4 cm water co...

Страница 4: ...e rests Use potholders or gloves to reposition CAUTION CHARBROILERS ARE HOT NEVER ATTEMPT TO CHANGE THE GRILL POSITION WHILE MEAT PRODUCTS ARE COOKING FLARE UPS CAN OCCUR UNEXPECTEDLY TURN OFF CHARBROILER AND ALLOW THE CHARBROILER TO COOL ADJUSTING HEAT PATTERN It is possible through this arrangement to have a high heat or searing section while having a low heat finishing or holding section For th...

Страница 5: ......

Страница 6: ... 6115RCB 6 H3 Y7045 1 GREASE DRAWER 6124RCB 6 H3 Y7044 1 GREASE DRAWER 6136RCB 7 G3 Y7047 2 SLIDE DRAWER 8 2A Y7113 4 LEG 9 H3 Y8831 1 GRATE 3 6115RCB 10 2F Y8830 2 4 6 GRATE 6 6115RCB 6124RCB 6136RCB 11 2F Y7553 2 4 6 RADIANT 6115RCB 6124RCB 6136RCB 12 G3 624038 1 GUARD WELD ASSEMBLY 6115RCB 12 G3 624037 1 GUARD WELD ASSEMBLY 6124RCB 12 G3 624039 1 GUARD WELD ASSEMBLY 6136RCB 13 2A Y6694 1 2 3 CL...