Page 

SPS5.1 Manual

12

Notes

SPS5.1 Manual

       Page 1

USER HANDBOOK

FOR

SPS5.1 TEMPERATURE CONTROLLER

STANTON

Temperature Controller

RUN

HALT

SET

SPS 5.1

Stanton Pottery Supplies Ltd.,
Canal Lane, Westport Lake,
Tunstall, STOKE-ON-TRENT,
Staffordshire, England.
ST6 4NZ

Tel:  +44 (0)1782 835467
Fax: +44 (0)1782 812435
email: [email protected]
www.stanton-kilns.co.uk

Issue:

5.1E01

Date:

10 July 98

© Stanton Pottery Supplies Ltd.
Manufactured in Staffordshire, U.K.

Содержание SPS5.1

Страница 1: ...oller RUN HALT SET SPS 5 1 Stanton Pottery Supplies Ltd Canal Lane Westport Lake Tunstall STOKE ON TRENT Staffordshire England ST6 4NZ Tel 44 0 1782 835467 Fax 44 0 1782 812435 email sales stanton kilns co uk www stanton kilns co uk Issue 5 1E01 Date 10 July 98 Stanton Pottery Supplies Ltd Manufactured in Staffordshire U K ...

Страница 2: ... wire size 1 5mm Temperature Ramp Rate to temperature t1 setting Range 20 to 240 C hour Resolution 20 C hour t1 setting Range 0 to 1310ºC Resolution 1ºC t2 setting Trim Range 0 to1310ºC Resolution 1ºC START DELAY setting Range 00 00 to 99hr 59min Resolution 1 min Control Accuracy Reading accuracy 0 25 FSD 1 digit P I D Control Cold junction compensation Environmental Operating temperature range 0 ...

Страница 3: ...is switched off and an error message is displayed for one minute After this period the controller resets itself and restarts as if a power failure had occurred If the potential error has cleared the instrument will proceed as normal If the error condition persists the instrument will repeat the error display cycle In the event of an error contact the supplier quoting the error number THERMOCOUPLE ...

Страница 4: ...rs which have been previously selected with the SET key Pressing this key when a firing in in progress will immediately abort the firing Pressing this key when READY is displayed enables the user to select firing parameters Pressing this key during a firing has no effect This is used to increment user input when in SET mode Pressing this key has no effect when READY is displayed or when a firing i...

Страница 5: ...S5 1 K4 is Mains Live input K5 is Mains Neutral input K6 is Earth input an Earth must be fitted to this controller VR1 is the display contrast control FS1 is the protective fuse 1 0A Anti surge Wickmann type TR5 T1A 250V Farnell Electronic Components 150 988 RS Components 226 6583 SPS5 1 Manual Page 5 2 4 Setting Pressing the SET key when READY is displayed causes the cur rently selected ramp rate...

Страница 6: ...actions to avoid a firing being aborted The instrument has no direct knowledge of how long the power has been off so the recovery action taken depends on where the instrument had reached in the firing sequence prior to power failure as detailed below Before Power Failure After Power Failure In READY mode Timing delayed start On Ramp 1 approaching t1 On Ramp 2 approaching t2 In Soak Period timing S...