GB
13
GB
7.
On the keypad, make sure:
•
is solid RED (Figure
).
• turns ON (Figure
).
8.
Use the laser tool.
9.
Position, press to turn the laser tool OFF.
Performing Accuracy Checks
NOTE:
• The laser tool is sealed and calibrated at the factory to the
listed in this manual.
• It is recommended that you perform the accuracy checks
before using the laser tool.
• Be sure to allow the laser tool adequate time to Auto-Level (at
least 5 seconds) prior to performing an accuracy check.
• The laser tool should be checked regularly to ensure its
accuracy, especially for precise layouts.
Horizontal Check
1.
Mount the laser tool in its horizontal position (Figure
)
on a tripod 5m from a wall, with the front of the laser tool
facing the wall (Figure
).
2.
Power ON the laser tool in Self-Levelling Mode
(Figure
).
3.
Wait 5 seconds for the laser tool to Auto-Level and make
sure the rotary laser beam is rotating.
4.
Where the laser line appears on the wall, mark point
D
1
(Figure
). If available, use a detector to more easily
locate the beam.
5.
Turn the laser tool 180° on the tripod. The back of the laser
tool should now be facing the wall (Figure
).
6.
Where the laser line appears on the wall, mark point
D
2
(Figure
).
7.
Measure the vertical distance between points
D
1
and
D
2
(Figure
).
• If the distance between
D
1
and
D
2
is
< 2.0mm
,
calibration is not required. You can continue using your
laser tool.
• If the distance between
D
1
and
D
2
is
, you must
have your laser tool calibrated at an authorized Stanley
service center. To locate your nearest Stanley service
center, go to www.2helpU.com.
8.
Turn the laser tool 90° so the left side faces the wall
(Figure
).
9.
Repeat steps
4.
through
7.
for the sides of the laser tool.
Vertical Check
1.
Mount the laser tool in its vertical position (Figure
) on
a level tripod 1m from a wall that is at least 2m high, with
the left side of the laser tool facing the wall (Figure
).
2.
Power ON the laser tool in Manual Mode
(Figure
).
3.
the wall, mark point
A
(Figure
):
4.
meet, mark point
B
.
5.
Where the rotary laser beam appears 2m up the wall, mark
point
D
1
.
6.
Turn the laser tool 180° on the tripod. The right side of the
laser tool should now be facing the wall (Figure
).
7.
Move the level tripod to align the rotary laser beam with
points
A
and
B
.
8.
Where the laser beam appears on the wall 2m above the
D
2
(Figure
).
9.
Measure the horizontal distance between points
D
1
and
D
2
(Figure
).
• If the distance between
D
1
and
D
2
is
< 1.2mm
,
calibration is not required. You can continue using your
laser tool.
• If the distance between
D
1
and
D
2
is
, you must
have your laser tool calibrated at an authorized Stanley
service center. To locate your nearest Stanley service
center, go to www.2helpU.com.
Содержание STHT77616
Страница 2: ...2 1 2 1 2 A C B...
Страница 3: ...3 1 2 3 5 6 4 7 8 9 _ _ _ _ E D...
Страница 4: ...4 2 1 H G 1 2 3 4 5 6 F...
Страница 5: ...5 3 4 5 6 1 2 I J K L...
Страница 6: ...6 1 2 5 m 5 m 5 m 5 m D1 D2 D2 D1 M N...
Страница 7: ...7 B A D1 2m D2 1m 2m 1m B A D1 O 1 2...
Страница 8: ...8 A B A 7 5 m P 1 2...