Specifications
STHT1-77409
Range
17.5cm to 15m (7in to 50ft)
Measuring Accuracy*
Typically ± 3.0mm (± 1/8in)*
Resolution
1mm (1/16in)
Laser Class:
Class 2 (IEC/EN60825-1: 2014)
Laser Wavelength
620-690nm, Power < 1mW
Auto Power Switch-off
After 180s
Battery Life (2 x AAA)
Up to 3000 Measurements
Dimension (H x D x W)
115 x 44 x 25mm (4.68 x 1.73 x 1.10in)
Weight (with Batteries)
100g (3.21oz)
Storage Temperature Range
-10° C ~ +60 C (14° F ~ 140° F)
Operating Temperature Range
0° C ~ +40° C (32° F ~ 104° F)
*
Measuring Accuracy
depends on the current conditions
:
•
Under
favorable
conditions (good target surface and room temperature) up to 10m (33ft).
•
Under
unfavorable
conditions (bright sunlight, a very weak reflecting target surface, or large temperature fluctuations),
the error can increase by ± 0.25 mm/m (± 0.003 in/ft) for distances over 10m (33ft).
Warranty
STANLEY warrants this product for a period of (2) years against deficiencies in material and workmanship. This
LIMITED WARRANTY does not cover products that are improperly used, abused, altered, or repaired. Please call
866-786-5924 for more information or return instructions. Unless otherwise noted, STANLEY will repair without
cost, any STANLEY product found to be defective, including parts and labor charges, or at STANLEY’s option,
will replace such tools or refund the purchase price, less the amount for depreciation, in exchange for the
defective tool. THIS LIMITED WARRANTY EXCLUDES ALL INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some
states do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may
not apply to you. This LIMITED LIFETIME WARRANTY gives you specific legal rights that may vary from state to
state. In addition to the warranty, STANLEY Lasers are covered by: 30-Day Money Back Guarantee. If you are
not completely satisfied with the performance of your STANLEY Laser for any reason, you can return it within
30 days from the date of purchase with a receipt for a full refund.
IMPORTANT NOTE: The customer is responsible for the correct use and care of the instrument. Moreover, the
customer is completely responsible for periodically checking the accuracy of the laser unit, and therefore for the
calibration of the instrument.
Calibration and care are not covered by warranty.
5
Содержание STHT1-77409
Страница 54: ...AAA 301 401 GR 54...
Страница 62: ...301 401 RU 62...
Страница 78: ...301 401 BG 78...
Страница 103: ...Notes...