NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
CONNECTED TO A POWER SOURCE
9
STORAGE / MAINTENANCE
Always disconnect the heater from the LP cylinder
before putting the heater into storage. If for any reason
the heater is to be stored indoors, the tank MUST be
disconnected from the LP cylinder, and the cylinder stored
outdoors in a well-ventilated area, out of the reach of
children, and in accordance with the Standard for Storage
and Handling of Petroleum Gases, ANSI/NFPA 58 - latest
edition and Natural Gas and Propane Installation Code,
CSA B149.1. The plastic valve plug or valve cover supplied
with the cylinder must be re-installed on the valve to
protect the fitting from damage.
NOTE: Installation and repair of this heater should be
done by a qualified service person.
ALWAYS
be sure to follow proper maintenance
procedures. This should include cleaning the inside of the
heater once a month and checking the spark gap at least
once a heating season. Re-gap the terminals to 0.160”
(4mm).
Never store an LP
cylinder inside of a
building or near any
other gas or oil
burning
appliances.