Stanley ST-60HB2-GFA Скачать руководство пользователя страница 6

© 2018 Pinnacle Climate Technologies Inc.

Propane Forced Air Heater User’s Manual (ST-60HB2-GFA)

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE 

CONNECTED TO A POWER SOURCE

6

OPERATION

Propane Supply / Information:
Propane (LP)

This heater is not supplied with a propane cylinder. Use only 

an approved propane cylinder.

LP Characteristics

 

Flammable, explosive under pressure, heavier than air 

and pools in low areas.

 

In its natural state, propane has no odor, but for your 

safety an odor that smells like rotten cabbage has been 

added.

 

Contact of propane (LP) gas with the skin can cause 

freeze burns.

 

Heater is manufactured for use with propane gas only. 

DO NOT attempt to convert to any other gas. Such 

modifications are dangerous and will void the warranty.

 

When heater is not in use, LP cylinder must be turned 

OFF.

 

Be sure that the LP cylinder is located on a level and 

stable surface.

 

DO NOT use this heater in a basement or below ground 

level. Propane is heavier than air and will always seek 

the lowest level. If you suspect a leak, shut off the valve 

at the LP cylinder immediately.

The propane (LP) cylinder must also be equipped with 

the following:

 

A collar to protect the gas valve.

 

A shut-off valve terminating a LP cylinder valve outlet 

as specified in the American National Standard for 

Compressed Gas Cylinder Valve Outlets and Inlets 

Connections.

 

A safety relief valve having direct communications with 

the vapor space of the LP cylinder.

 

The heater must operate on vapor withdrawal from the 

operating cylinder.

The amount of Propane (LP) used with this heater 

varies due to:

 

The amount of gas in the cylinder of LP.

 

The temperature of the LP tank and its 

surroundings.

 

Always keep LP cylinder fastened and upright.

 

Avoid tipping the LP cylinder on its side 

when 

connected to a regulator, since this may cause 

damage to diaphragm in the regulator.

 

Handle valves with care.

 

Never connect an unregulated LP cylinder to a 

construction heater.

 

DO NOT subject LP cylinder to excessive heat.

 

Tightly close the gas shutoff valve on the LP cylinder 

after each use. 

 

All fittings must be protected when disconnected from 

the LP cylinder.

 

Never store an LP cylinder inside a building or in the 

vicinity of any gas burning appliances.

Minimum Number of LP Cylinders

Average

Temp

(ºF / ºC)

60HB2-GFA

100 lb. 

(45 kg)

cylinder

32º / 0º

1

20º / -7º

1

10º / -12º

1

0º / -18º

1

-10º / -23º

2

-20º / -29º

2

The table above shows the minimum number of 100 lb. 

(45 kg) LP cylinders required in cold weather. Your local LP 

dealer will help you select the proper LP supply system.

Propane is safe to 

use when properly 

handled. Careless 

handling of the LP 

cylinder could result 

in a fire and / or an 

explosion.

CAUTION

Содержание ST-60HB2-GFA

Страница 1: ...HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LA BEL ETC CONTACT THE MANUFACTURER FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARD BOARD A...

Страница 2: ...n in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY UNDERSTAND...

Страница 3: ...t a three square foot 2 800 sq cm opening of outside air for every 100 000 BTU Hr 29 kW heater rating Refer toVentilation on Page 8 for further instructions WHATTO DO IFTHE SMELL OF GAS IS PRESENT DO...

Страница 4: ...se of the heater If there is excessive abrasion or wear or if the hose is cut replace it with the proper assembly Manifold Minimum and Maximum Inlet Pressure ST 60HB2 GFA Man 5 PSI Min 25 PSI Max 250...

Страница 5: ...witch Outer Shell Inner Shell Guard Power Cord Piezo Ignitor Backside Model ST 60HB2 GFA BTU 60 000 Fuel Consumption Lb hr kg hr 2 75 1 25 Maximum Operating Hours 8 Required Cylinder Lb kg 20 9 Fuel T...

Страница 6: ...valve outlet as specified in the American National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Connections A safety relief valve having direct communications with the vapor space of...

Страница 7: ...r leaks with soap solution see below Checking For Leaks To check for leaks make up a 50 50 solution of dish soap and water Apply this solution to all gas connections If bubbles appear there is a leak...

Страница 8: ...hold the Gas Control Button for 30 seconds 7 If the burner doesn t stay lit repeat lighting procedures Shutdown Instructions To Shut Off the Heater 1 Turn gas supply OFF by turning the LP cylinder val...

Страница 9: ...m Gases ANSI NFPA 58 latest edition and Natural Gas and Propane Installation Code CSA B149 1 The plastic valve plug or valve cover supplied with the cylinder must be re installed on the valve to prote...

Страница 10: ...ck housing for damage Be sure there are no dents in the housing obstructing the fan 4 Straighten all fan blades 5 Replace motor assembly Heater will not fire ignite 1 No spark at module 2 Incorrect sp...

Страница 11: ...lace and return the item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limite...

Страница 12: ...STANLEY and the STANLEY logo are trademarks of Stanley Black Decker Inc or an affiliate thereof and are used under license Manufactured by Pinnacle Climate Technologies Inc Sauk Rapids MN 56379 Made...

Страница 13: ...NSTRUCTIONS UNE TIQUETTE ETC COMMUNIQUER AVEC LE FABRICANT RISQUE D INCENDIE DE BR LURE D INHALATION ET D EXPLOSION GARDER LES MAT RIAUX SOLIDES INFLAMMABLES TELS LES MAT RIAUX DE CONSTRUCTION LE PAPI...

Страница 14: ...tions contenues dans ce manuel ne sont pas suivies la lettre un incendie ou une explosion peuvent survenir et causer des dommages mat riels des blessures ou la mort NE PAS UTILISER CETTE CHAUFFERETTE...

Страница 15: ...l air ext rieur pour chaque 29 kW h 100 000 BTU h du r gime nominal de la chaufferette Voir la rubrique Ventilation la page 8 pour plus de d tails QUE FAIRE SI UNE ODEUR DE GAZ EST D TECT E NE PAS te...

Страница 16: ...ssive ou s il est coup le remplacer par l ensemble appropri Pressions d entr e collecteur minimum et maximum ST 60HB2 GFA Collecteur 5 PSI 34 5 kPa Min 25 PSI 172 kPa Max 250 PSI 1724 kPa Pour tre uti...

Страница 17: ...veloppe ext rieure Enveloppe int rieure Protection Cordon lectrique Allumage piezo lectrique arri re Mod le n ST 60HB2 GFA BTU 60 000 Consommation de carburant kg h 1 25 Nombre maximal d heures de fon...

Страница 18: ...la sortie du robinet de la bouteille de propane comme sp cifi dans les normes am ricaines pour les sorties et les entr es de robinets d vacuation pour bouteille de gaz Une soupape de s ret en communic...

Страница 19: ...a bouteille de gaz et v rifier qu il n y a pas de fuites avec une solution d eau savonneuse voir ci dessous V rification des fuites Pour v rifier qu il n y a pas de fuites pr parer une solution 50 50...

Страница 20: ...r le bouton de commande de gaz pendant 30 secondes 7 Si le br leur ne reste pas allum r p ter les proc dures d allumage Instructions pour l arr t Pour teindre la chaufferette 1 FERMER l alimentation e...

Страница 21: ...NFPA 58 et le Code d installation du propane CSA B149 1 Le bouchon en plastique du robinet de la bouteille fourni avec la bouteille doit tre install bien serr lorsque la bouteille est d branch e de l...

Страница 22: ...cass s 2 Appuyer sur l interrupteur rouge pour le mettre sur MARCHE 3 S assurer que le bo tier n est pas endommag S assurer qu aucune obstruction n entrave le ventilateur 4 Redresser les pales 5 Rempl...

Страница 23: ...et d terminera s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dans un...

Страница 24: ...et le logo STANLEY sont des marques de commerce de Stanley Black Decker Inc ou d une de ses filiales et sont utilis es sous license Fabriqu par Pinnacle Climate Technologies Inc Sauk Rapids MN 56379...

Страница 25: ...UAL DE INSTRUCCIONES ETIQUETAS ETC COMUN QUESE CON EL FABRICANTE PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N MANTENGA LOS COMBUSTIBLES S LIDOS COMO MATERIALES DE CONSTRUCCI N PAPEL O CART N...

Страница 26: ...en espacios interiores Si no sigue la informaci n de este manual al pie de la letra puede producirse un incendio o una explosi n provocando da os materiales lesiones corporales o p rdida de la vida N...

Страница 27: ...re exterior por cada 100 000 BTU h 29 kW h que genere el calentador Consulte Ventilaci n en la p gina 8 para obtener m s instrucciones QU HACER SI PERCIBE OLOR A GAS NO trate de encender el calentador...

Страница 28: ...e con el conjunto correcto Presi n de entrada del m ltiple m nima y m xima ST 60HB2 GFA M ltiple 5 PSI 34 5 kPa M n 25 PSI 172 kPa M x 250 PSI 1724 kPa Para usarse con gas propano LP nicamente ADVERTE...

Страница 29: ...otecci n de seguridad Cable el ctrico Encendedor piezoel ctrico lado posterior N de modelo ST 60HB2 GFA BTU 60 000 Consumo de combustible lb h kg h 2 75 1 25 Horas m ximas de funcionamiento 8 Tanque r...

Страница 30: ...ula del tanque de LP seg n la especificaci n de la Norma Nacional Americana para la conexi n de entradas y salidas de v lvulas de tanques de gas comprimido Una v lvula de escape de seguridad con comun...

Страница 31: ...de LP y revise que no haya fugas usando una soluci n de jab n vea abajo Inspecci n de fugas Para verificar si hay fugas prepare una soluci n mitad detergente para platos y mitad agua Aplique esta sol...

Страница 32: ...manteniendo presionado el bot n de control de gas por 30 segundos 7 Si el quemador se apaga repita el procedimiento de encendido Instrucciones de apagado Para apagar el calentador 1 Gire HACIA LA DERE...

Страница 33: ...gases de petr leo ANSI NFPA 58 y el C digo de Instalaci n de gas natural y gas propano CSA B149 1 Se debe reinstalar el tap n de pl stico o la cubierta de la v lvula del tanque para proteger la uni n...

Страница 34: ...ojo a la posici n de encendido ON 3 Aseg rese que el alojamiento no est da ado Aseg rese que el alojamiento no tenga abolladuras que obstruyan al ventilador 4 Enderece todas las aspas del ventilador 5...

Страница 35: ...por adelantado Si Pinnacle Climate Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta...

Страница 36: ...Y y el logotipo de STANLEY son marcas comerciales de Stanley Black Decker Inc o de una afiliada de la misma y se usan bajo licencia Fabricado por Pinnacle Climate Technologies Inc Sauk Rapids MN 56379...

Отзывы: