14
TECHNICAL DATA
IS100DS
IS80DS
Nominal Output: (kW)
15.3kW
14kW
Mean Flue Gas
Temperature
o
C
267
267
Typical refuelling intervals to
obtain nominal outputs:
0.72 hrs
0.72 hrs
CO at 13% O
2
0.10%
0.10%
Gross Weight
150kgs
125kgs
Flue Outlet
150mm (6”)
150mm (6”)
Efficiency
79%
79%
Flue Draught
12Pa
12Pa
Log Size
650mm
550mm
Model
Energy
Efficiency
Class
Heat Output
to Room
Heat Output
to Water
Energy
Efficiency
Index
Preferred
Fuel
Nominal
Heat
Output
Net Efficiency
IS100DS
A
15.3
N/A
105.55
Wood
15.3
79
IS80DS
A
14.0
N/A
105.55
Wood
14.0
79
LIGHTING
Before lighting the stove check with the installer that the installation work and commissioning checks described
previously have been carried out correctly and that the chimney has been swept clean, is sound and free from
any obstructions. As part of the stoves commissioning and handover the installer should demonstrate how to
operate the stove correctly.
LIGHTING THE STOVE
1.
Open the fire door and open the primary & secondary air inlets by pushing the two air control levers to
the right.
2.
Cover the grate with crumpled pieces of paper and lay 10-12 pieces of kindling on top of the paper
towards the back of the firebox.
3.
lgnite and close the fire door.
4.
When the kindling is well alight open the fire door and add more kindling of a larger size to sustain the
fire. Close the fire door.
5.
When a hot fire bed is established, close the primary air inlet fully and add larger pieces of wood.
6.
When well lit, adjust the secondary air control as required depending on the heat output required. The
exact settings will depend on the draught conditions of the chimney to which the unit is connected.
Depending on the quality of the firewood, it may be necessary to open the primary air inlet to sustain the desired
burn rate, but during normal operation, the primary air lever should not be opened by more than 10mm.