Страница 2: ......

Страница 3: ...warranty validation record must be submitted to validate the warranty SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL REPAIRS AND OR SERVICE TO THIS TOOL MUST ONL...

Страница 4: ...messages that follow this symbol to avoid possible injury or death This safety alert and signal word indicates an imminently hazardous situation which if not avoided will result in death or serious in...

Страница 5: ...uplers and cause overheating of the hydraulic system Do not operate the tool at oil temperatures above 140 F 60 C Operation at higher oil temperatures can cause operator discomfort and may damage the...

Страница 6: ...NOT ABUSE HOSE DO NOT USE KINKED TORN OR DAMAGED HOSE 3 MAKE SURE HYDRAULIC HOSES ARE PROPERLY CON NECTED TO THE TOOL BEFORE PRESSURING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN...

Страница 7: ...TH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUMALLOWABLE CURRENT LEAKAGE INACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A G 3 DO NOT EX...

Страница 8: ...175 1 25 4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 Typical Hose C...

Страница 9: ...operator discomfort at the tool Filter minimum full flow filtration 25 microns 25 microns 25 microns 25 microns Sized for flow of at least For cold temp startup and maximum dirt holding capacity 30 G...

Страница 10: ...e tool The air supply must be minimum 30 cfm at 120 psi Supplying less than these specifications may result in inadequate extraction of rock cuttings cause cuttings to migrate up the drill steel and i...

Страница 11: ...ERATION If the breaker is to be used during cold weather preheat the hydraulic fluid at low engine speed When using the normally recommended fluid fluid temperature should be at or above 50 F 10 C 400...

Страница 12: ...by STANLEY Supply hoses must have a minimum working pressure rating of 2500 psi 172 bar Do not exceed the rated flow Rapid failure of the internal seals may result See Specifications in this manual f...

Страница 13: ...blocked Remove restriction Orifice plug blocked Remove restriction Fluid too hot above 140 F 60 C or too cold below 60 F 16 C Check power unit for proper fluid temperature Bypass cooler to warm the f...

Страница 14: ...then unscrew the entire tester assembly from the accumulator charging valve If pressure is low charge the accumulator as described in the following procedure 7 Tighten the 5 8 inch hex locking nut on...

Страница 15: ...Dip or spray the entire tool 3 Cycle the tool hydraulically several times before storing away GENERAL SERVICE NOTES 1 If the breaker is repainted after servicing be sure to mask off the vent in the v...

Страница 16: ...XIS 16 0 M SEC UNCERTAINTY K 1 2 M SEC MEASURED VIBRATION EMISSION VALUE WITH UNCERTAINTY Z AXIS 17 2 M SEC ACCESSORIES DRILL STEELS FOR USE WITH AIR 1 in Hex 4 1 4 in H Thread 24 in 61 cm UC 05170 1...

Страница 17: ...33 31 21 30 59 60 29 27 26 25 24 23 22 21 69 76 97 77 78 98 79 96 80 81 82 91 92 93 94 95 86 90 83 89 88 83 84 85 87 54 55 53 52 51 50 34 20 35 34 36 49 48 38 40 39 41 42 5 3 45 44 43 1 47 2 3 4 5 7...

Страница 18: ...O RING 42 04777 1 THROTTLE VALVE 43 04778 1 BLOWER TUBE NUT 44 00016 1 O RING ITEM PART NO QTY DESCRIPTION 45 00175 1 O RING 46 04660 1 HOUSING 47 00772 1 KEY 48 07291 1 MODIFIED CAPSCREW 49 04512 1...

Страница 19: ...VE GEAR 101 00026 2 O RING 102 04776 1 TUBE CONNECTOR 103 04796 1 NAME TAG 104 04768 1 WATER VALVE SK58120 ONLY 105 03972 1 COUPLER FEMALE 106 03973 1 COUPLER MALE 107 30646 1 MOTOR ASSEMBLY SK58110 1...