background image

SK47 User

 Manual ◄ 11

OPERATION

open the hydraulic valve lever further. If the rock bit 

still  does  not  rotate  adjust  the  motor  control  knob 

until rotation is achieved.

9.  After the rock bit has carved out a depression in the 

material being drilled, open the hydraulic valve lever 

fully.  Readjust  the  motor  control  knob  to  obtain  a 

good drilling speed. Adjust the air valve to ensure 

the cuttings are being extracted from the drill hole.

10. Keep the drill steel centered in the hole.

11. 

Insufficient air flow can cause the drill steel to bind 

in the hole.

12. 

Apply adequate feed pressure to the sinker drill to 

maintain optimum drilling performance.

13. 

When drilling deep holes, it is advantageous to stop 

drilling every 1 to 2 minutes. This allows the receiver 

and hoses to charge and provide a short burst of 

air when the tool is again turned on to clear excess 

cutting from the hole.

14. 

When the bottom of the tool comes within 6 inches of 

the drill hole, it is time to either add another section 

of drill steel or replace the existing drill steel with a 

longer section. Close the hydraulic valve lever but 

leave the air valve 

ON

 and then lift the tool with drill 

steel  and  rock  bit  out  of  the  hole.  Leaving  the  air 

valve 

ON

 helps prevent cuttings from falling around 

the bit while the bit is lifted from the hole.

15. 

When the tool, drill steel and bit have been removed 

from the drill hole, turn the valve lever 

OFF

 and turn 

the hydraulic supply circuit control valve 

OFF

 before 

changing the drill steel or rock bit.

COLD WEATHER OPERATION

If the breaker is to be used during cold weather, preheat 

the hydraulic fluid at low engine speed. When using the 

normally  recommended  fluid,  fluid  temperature  should 

be  at  or  above  50  °F/10  °C  (400  ssu/82  centistokes) 

before use.

Damage to the hydraulic system or breaker can result 

from use with fluid that is too viscous or thick.

FLUSHING REQUIREMENTS

• 

The SK47 is designed for air flushing only.

• 

The minimum of CFM/7 liters per second at 75 psi/5 

bar of compressed air should be used for flushing 

the chips out of the drilled hole.

• 

The  minimum  recommended  hose  size  is  3/8-

inch/10 mm ID and must have a minimum working 

pressure rating of 150 psi/10 bar or 150 percent of 

the  maximum  pressure  produced  by  the  system, 

whichever is higher.

• 

Air hoses must have an oil-resistant inner surface 

and  an  abrasion-resistant  exterior  surface.  When 

severe  operating  conditions  make  the  possibility 

of  cutting  or  damaging  the  hose  likely,  the  hose 

shall  be  of  extra-ply  armored,  or  other  protective 

construction.

• 

Pressure regulators shall be used to limit maximum 

air pressure at the tool to 100 psi/7 bar.

•  An accessible means for shutting off the air supply 

to the sinker drill should be provided.

• 

Automatic filtering systems are recommended.

Содержание SK47

Страница 1: ...2014 STANLEY Black Decker Inc New Britain CT 06053 U S A 10323 2 2018 Ver 9 USER MANUAL Safety Operation and Maintenance SK47 HYDRAULIC SINKER DRILL...

Страница 2: ......

Страница 3: ...y Note The warranty validation record must be submitted to validate the warranty SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL REPAIRS AND OR SERVICE TO THIS TO...

Страница 4: ...messages that follow this symbol to avoid possible injury or death This safety alert and signal word indicates an imminently hazardous situation which if not avoided will result in death or serious in...

Страница 5: ...connecting Use only lint free cloths Failure to do so may result in damage to the quick couplers and cause overheating of the hydraulic system Do not operate the tool at oil temperatures above 140 F 6...

Страница 6: ...ESSURING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN PORT SYSTEM RETURN HOSE MUST ALWAYS BE CONNECTED TO TOOL OUT PORT REVERSING CONNECTIONS MAY CAUSE REVERSE TOOL OPERATION WHICH...

Страница 7: ...TH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUMALLOWABLE CURRENT LEAKAGE INACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A G 3 DO NOT EX...

Страница 8: ...Pressure 2500 175 1 25 4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 T...

Страница 9: ...operator discomfort at the tool Filter minimum full flow filtration 25 microns 25 microns 25 microns 25 microns Sized for flow of at least For cold temp startup and maximum dirt holding capacity 30 G...

Страница 10: ...si Supplying less than these specifications may result in inadequate extraction of rock cuttings cause cuttings to migrate up the drill steel and into the tool and result in tool damage diminish drill...

Страница 11: ...e bit is lifted from the hole 15 When the tool drill steel and bit have been removed from the drill hole turn the valve lever OFF and turn the hydraulic supply circuit control valve OFF before changin...

Страница 12: ...LEY Supply hoses must have a minimum working pressure rating of 2500 psi 172 bar Do not exceed the rated flow and pressure See Specifications in this manual for correct flow rate and pressure rating R...

Страница 13: ...ract the stem then unscrew the entire tester assembly from the accumulator charging valve If pressure is low charge the accumulator as described in the following paragraph 7 Tighten the 5 8 inch hex l...

Страница 14: ...14 SK47 User Manual Figure 2 Charging the Accumulator CHARGING THE ACCUMULATOR...

Страница 15: ...blocked Remove restriction Orifice plug blocked Remove restriction Fluid too hot above 140 F 60 C or too cold below 60 F 16 C Check power unit for proper fluid temperature Bypass cooler to warm the fl...

Страница 16: ...ith Air 7 8 in 22 mm Hex 4 1 4 in 108 mm H Thread 24 in 61 cm UC 05174 Carbide Rock Bits for use with Air 1 3 8 in 34 9 mm Diameter H Thread 05177 1 1 2 in 38 1 mm Diameter H Thread 05178 2 in 50 8 mm...

Страница 17: ...SK47 User Manual 17 SK47 PARTS ILLUSTRATION 83 Motor Assy...

Страница 18: ...VALVE 32 08097 1 VALVE SPOOL 33 08098 1 SPRING 34 08104 1 O RING PLUG 35 04934 1 CUP SEAL 36 04780 1 WASHER 37 04386 1 CUP SEAL 38 02022 1 O RING 39 00473 1 O RING ITEM PART NO QTY DESCRIPTION 40 0493...

Страница 19: ......

Страница 20: ...STANLEY Infrastructure 6430 SE Lake Road Portland Oregon 97222 USA 503 659 5660 Fax 503 652 1780 www stanleyinfrastructure com...

Отзывы: