background image

4 ► SD67 

User Manual

Always observe safety symbols. They are included for your safety and for the protection of the tool. 

LOCAL SAFETY REGULATIONS

Enter  any  local  safety  regulations  here.    Keep  these  instructions  in  an  area  accessible  to  the  operator  and 

maintenance personnel.

Safety symbols and signal words, as shown below, are used to emphasize all operator, maintenance and repair 

actions which, if not strictly followed, could result in a life-threatening situation, bodily injury or damage to equipment.

This is the safety alert symbol. It is used to alert you to potential personal injury 

hazards.  Obey  all  safety  messages  that  follow  this  symbol  to  avoid  possible 

injury or death.
This  safety  alert  and  signal  word  indicate  an  imminently  hazardous  situation 

which, if not avoided, will

 result in 

death or serious injury

.

This  safety  alert  and  signal  word  indicate  a  potentially  hazardous  situation 

which, if not avoided, 

could result in 

death or serious injury

.

This  safety  alert  and  signal  word  indicate  a  potentially  hazardous  situation 

which, if not avoided, 

could result in 

death or serious injury

.

This signal word indicates a potentially hazardous situation which, if not avoided, 

may result in property damage.

This signal word indicates a situation which, if not avoided, will

 result in damage 

to the equipment

.

This signal word indicates a situation which, if not avoided, 

may result in damage 

to the equipment

.

SAFETY SYMBOLS

Содержание SD67

Страница 1: ...2014 Stanley Black Decker Inc New Britain CT 06053 U S A 17488 7 2017 Ver 10 SD67 HYDRAULIC SPIKE DRIVER USER MANUAL Safety Operation and Maintenance...

Страница 2: ...2 SD67 User Manual...

Страница 3: ...rranty Note The warranty validation record must be submitted to validate the warranty SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL REPAIRS AND OR SERVICE TO TH...

Страница 4: ...messages that follow this symbol to avoid possible injury or death This safety alert and signal word indicate an imminently hazardous situation which if not avoided will result in death or serious in...

Страница 5: ...ed work areas such as excessive slopes and dangerous terrain conditions Establish a training program for all operators to ensure safe operation Do not operate the tool unless thoroughly trained or und...

Страница 6: ...ESSURING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN PORT SYSTEM RETURN HOSE MUST ALWAYS BE CONNECTED TO TOOL OUT PORT REVERSING CONNECTIONS MAY CAUSE REVERSE TOOL OPERATION WHICH...

Страница 7: ...SORBENT CLOTH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUM ALLOWABLE CURRENT LEAKAGE IN ACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A...

Страница 8: ...4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 Typical Hose Connections...

Страница 9: ...bar 152 159 bar 145 155 bar 250 psi 250 psi 250 psi 250 psi 17 bar 17 bar 17 bar 17 bar 400 ssu 400 ssu 400 ssu 400 ssu 82 centistokes 82 centistokes 82 centistokes 82 centistokes 140 F 140 F 140 F 1...

Страница 10: ...all hose couplers with a clean lint free cloth before making connections 2 Connect the hoses from the hydraulic power source to the hose couplers on the spike driver Connect the return hose first and...

Страница 11: ...hoses couplings and other parts with replacement parts recommended by Stanley Hydraulic Tools Supply hoses must have a minimum working pressure rating of 2500 psi 175 bar Permit only experienced pers...

Страница 12: ...re hose will pulse more than normal Have recharge by authorized dealer Fluid too hot above 140 F 60 C Provide cooler to maintain proper fluid temperature Ram is not sliding freely in the spike driver...

Страница 13: ...to the valve on the tester 6 Adjust the regulator on the nitrogen bottle to 600 psi 42 bar NOTE It may be necessary to set the regulator at 650 700 psi 45 48 bar to overcome any pressure drop through...

Страница 14: ...0 lpm 138 bar Noise Level Lwa 106 Vibration Level 20 0 m s2 ACCESSORIES SECONDARY FOOT CUPS Special spikes listed below may require the use of a special spike drive foot with changeable cups Order spi...

Страница 15: ...Manual 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 60 61 24 SD67 PARTS ILLU...

Страница 16: ...IVER FOOT 73187 34 73322 1 SPIKE DRIVER FOOT SOLID 73187 1 SPIKE DRIVER FOOT EXTENDED SOLID 35 16732 1 O RING 36 20498 2 COMPRESSION COIL SPRING Item P N Qty Description 37 20499 1 CHARGE VALVE 38 205...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...Stanley Hydraulic Tools 3810 SE Naef Road Milwaukie Oregon 97267 5698 USA 503 659 5660 Fax 503 652 1780 www stanleyhydraulics com...

Отзывы: