To  check  or  charge  the  accumulator  the  following 

equipment is required:

• 

Accumulator tester (Part Number 02835).

• 

Charging  assembly  (P/N  31254—includes  a 

regulator, hose and fitting).

• 

Nitrogen  bottle  with  an  800  psi/56  bar  minimum 

charge.

1. 

On  charge  valves  containing  5/8  inch  hex  locking 

nuts, first loosen the locking nut 1-1/2 turns.

2. 

Holding  the  chuck  end  of  the  Stanley  tester  (P/N 

02835),  turn  the  gauge  fully  counterclockwise  to 

ensure  the  stem  inside  the  chuck  is  completely 

retracted.

3. 

Thread the tester onto the charging valve of the tool 

accumulator (do not advance the gauge end into the 

chuck end. Turn as a unit). Seat the chuck on the 

accumulator charging valve and hand tighten only.

4.  Advance the valve stem by turning the gauge end 

clockwise.

5.  Connect the charging assembly to the valve on the 

tester.

6.  Adjust  the  regulator  on  the  nitrogen  bottle  to  600 

psi/42 bar.

NOTE: It may be necessary to set the regulator at 

650–700  psi/45–48  bar  to  overcome  any  pressure 

drop through the charging system.

7.  Open the valve on the charging assembly hose. 

When  the  tester  gauge  reads  600–700  psi/42–48 

bar, close the valve on the charging assembly hose 

and remove the charging valve.

8. 

Turn the gauge end of the tester fully counterclockwise 

to  retract  the  plunger  in  the  chuck.  Remove  the 

tester from the charger valve.

9.  On  charge  valves  containing  5/8  inch  hex  locking 

nuts, tighten the locking nut.

TESTING THE ACCUMULATOR

1. 

Follow  Steps  1  through  4  in  “Charging  The 

Accumulator”

.

2. 

Read the pressure on the gauge (pressure should 

be between 500–600 psi/35–42 bar).

3.  If the pressure is low, recharge the tool.

Figure 2. Charging the Accumulator

CHARGING THE ACCUMULATOR

31254: Accumulator Charge Kit

Includes: Liquid filled gauge with Snub Valve, 

Hose,  Charge  fitting,  02835  Tester  and  Box 

(not pictured).

Содержание SD67

Страница 1: ...2014 Stanley Black Decker Inc New Britain CT 06053 U S A 17488 7 2017 Ver 10 SD67 HYDRAULIC SPIKE DRIVER USER MANUAL Safety Operation and Maintenance...

Страница 2: ...2 SD67 User Manual...

Страница 3: ...rranty Note The warranty validation record must be submitted to validate the warranty SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL REPAIRS AND OR SERVICE TO TH...

Страница 4: ...messages that follow this symbol to avoid possible injury or death This safety alert and signal word indicate an imminently hazardous situation which if not avoided will result in death or serious in...

Страница 5: ...ed work areas such as excessive slopes and dangerous terrain conditions Establish a training program for all operators to ensure safe operation Do not operate the tool unless thoroughly trained or und...

Страница 6: ...ESSURING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN PORT SYSTEM RETURN HOSE MUST ALWAYS BE CONNECTED TO TOOL OUT PORT REVERSING CONNECTIONS MAY CAUSE REVERSE TOOL OPERATION WHICH...

Страница 7: ...SORBENT CLOTH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUM ALLOWABLE CURRENT LEAKAGE IN ACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A...

Страница 8: ...4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 Typical Hose Connections...

Страница 9: ...bar 152 159 bar 145 155 bar 250 psi 250 psi 250 psi 250 psi 17 bar 17 bar 17 bar 17 bar 400 ssu 400 ssu 400 ssu 400 ssu 82 centistokes 82 centistokes 82 centistokes 82 centistokes 140 F 140 F 140 F 1...

Страница 10: ...all hose couplers with a clean lint free cloth before making connections 2 Connect the hoses from the hydraulic power source to the hose couplers on the spike driver Connect the return hose first and...

Страница 11: ...hoses couplings and other parts with replacement parts recommended by Stanley Hydraulic Tools Supply hoses must have a minimum working pressure rating of 2500 psi 175 bar Permit only experienced pers...

Страница 12: ...re hose will pulse more than normal Have recharge by authorized dealer Fluid too hot above 140 F 60 C Provide cooler to maintain proper fluid temperature Ram is not sliding freely in the spike driver...

Страница 13: ...to the valve on the tester 6 Adjust the regulator on the nitrogen bottle to 600 psi 42 bar NOTE It may be necessary to set the regulator at 650 700 psi 45 48 bar to overcome any pressure drop through...

Страница 14: ...0 lpm 138 bar Noise Level Lwa 106 Vibration Level 20 0 m s2 ACCESSORIES SECONDARY FOOT CUPS Special spikes listed below may require the use of a special spike drive foot with changeable cups Order spi...

Страница 15: ...Manual 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 60 61 24 SD67 PARTS ILLU...

Страница 16: ...IVER FOOT 73187 34 73322 1 SPIKE DRIVER FOOT SOLID 73187 1 SPIKE DRIVER FOOT EXTENDED SOLID 35 16732 1 O RING 36 20498 2 COMPRESSION COIL SPRING Item P N Qty Description 37 20499 1 CHARGE VALVE 38 205...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...Stanley Hydraulic Tools 3810 SE Naef Road Milwaukie Oregon 97267 5698 USA 503 659 5660 Fax 503 652 1780 www stanleyhydraulics com...

Отзывы: