8
Test
Action
Observation
Controller
Reader
Normal
Operation
The green system status LED
flashes at normal rate.
The normal operation
of the reader.
Door status LEDs off.
One-Touch™
View Mode
Hold down the
One-Touch™
button for less than 2
seconds. Present keys and
press RTE switches and
observe LEDs. Automatically
exits after 2 minutes.
The green system status LED
flashes at normal rate.
Green on - valid key has been
presented to reader.
Green flash - invalid key has
been presented to reader.
Red on - door open.
Yellow on - RTE switch has been
pressed.
One-Touch™
Active Mode
Hold down the
One-Touch™
button for 2 to 4 seconds.
The green system status LED
flashes faster than normal.
The normal operation
of the reader LED
changes, e.g. if
default is red, it turns