If there are other oil fired appliances connected to the
oil storage tank especially appliances with oil pumps
e.g. oil fired boilers or range cookers, it is recom-
mended that a separate oil supply line is taken from
the oil tank to the stove. The separate oil supply line
to the stove will avoid the possibility of the pumped
appliance taking oil from the stove burner and control
valve. A suitable shut off valve should be fitted near
the stove and be accessible at all times.
NOTE:
Fuel to the appliance should be gravity fed
only.
8
These requirements are in accordance with the fol-
lowing relevant sections of BS 5410: Part 1 O.F.S.
A105 Oil Stove Standard. The Building Regulations
for Scotland, Ireland, Northern Ireland, England &
Wales.
CLEARANCES TO COMBUSTIBLE MATERIAL
Clearances to Combustible material
From Sides - 510mm
From Top - 510mm
From Rear - 510mm
From Front - 510mm
CLEARANCES TO NON-COMBUSTIBLE
MATERIAL
Fig.5
Fig.7
Fig.6
Fig.4