background image

1.     GENERAL

1.1

Installation and servicing must only be 
carried out by a competent person.

1.2

In all correspondence, please quote the 
appliance type and serial number which 
can be found on the data badge located at
the rear of the stove.

1.3

Ensure that curtains are not positioned 
above the stove, and that there is at least 
a clearance of 300mm between the sides 
of the stove and any curtains.

1.4

If any cracks are observed in the glass 
panel, do not use the appliance until the 
glass has been replaced.

2.

LIGHTING THE STOVE

2.1

Ensure the control is pointing to the off 

2.2

Depress control knob and rotate anti-
clockwise until a click is heard and the 

knob is pointing at the ignition symbol (

*

), 

the pilot should now be lit.

2.3

Depress for 5 to 10 seconds and then 
release, the pilot should remain alight.  If 
the pilot does not light, repeat the above 
procedure.

2.4

If it will not light after repeated attempts, 
contact the retailer or installer from whom 
the appliance was purchased.  

2.5

The appliance may now be turned to the 
high position to ignite the main burner, 
then controlled between high and low as 
desired.

3.

TURNING THE STOVE OFF

3.1

Depress the control knob and turn clock-
wise until the knob is pointing at the off 

NOTE:  THE YELLOW FLAMES WILL
APPEAR WHEN THE FIRE HAS GAINED
SUFFICIENT HEAT - TYPICALLY 10 TO 
20 MINUTES.

IF THE APPLIANCE IS EXTINGUISHED 
OR GOES OUT IN USE, WAIT 3 MIN-
UTES BEFORE ATTEMPTING TO RE-
LIGHT THE APPLIANCE.

4.

CLEANING THE STOVE

4.1

Remove the ceramic coals and place on a
dry, clean surface.  Remove the front coal 
ceramic, please handle with care.

4.2

Clean the flame baffle ceramic piece and 
burner using a vacuum cleaner with soft 
brush attachment, ensure all debris are 
removed from the burner ports.

4.3

Replace the ceramics by referring to 
Section 5.

5.

ARRANGEMENT OF FUEL-BED COM-
PONENTS

The major ceramic components can be 
found inside the firebox, remove the cast 
iron door and remove all the protective 
packaging from these components.

NOTE: THE CAST IRON DOOR IS 
HEAVY, TAKE EXTREME CARE WHEN 
HANDLING.

The loose coals should be arranged as 
specified in the following steps, care 
should be taken to ensure that there is 
sufficient space between the coals to 
allow flames to pass through.

5.1

Place the flame baffle onto the shelf at the
rear of the tray and push up against the 
rear ledge, see Fig 11.

5.2

Locate the front coal moulding in front of 
the flame baffle ensuring that the end legs
sit flat against the burner skin, see Fig 12.

5.3

Place three large coals on the front coal 
so that they lean against the flame baffle, 
and four large coals on the flame baffle so
that they sit on the fingers, see Fig 13.

5.4

Place two small coals at each end of the 
front coal so that they lean against the 
flame baffle, and a further two large coals 
on the flame baffle, one at each end, see 
Fig 14.

5.5

Place five small coals along the rear of 
the flame baffle, resting against the rear 
ledge, see Fig 15.

NOTE: ENSURE THAT THE COALS ARE
POSITIONED, AS DETAILED ABOVE.  
ONLY USE THE CORRECT AMOUNT OF
COALS, AS SPECIFIED IN THE DIA-
GRAMS.

INSTRUCTIONS FOR USE

2

position (   ).

position (   ).

Содержание MAEVE

Страница 1: ...WITH GRILL Country AT BE DK FI FR DE GR IS IE Natural Gas LPG Country IT LU NL NO PT ES SE GB Natural Gas LPG WARNING Do not attempt to burn rubbish in this stove This stove must only be operated with the door secured firmly in position The outer casting of this stove will become hot whilst in operation it is therefore recommended that the appliance be guarded to protect the young and infirm using...

Страница 2: ...G30 29MB 6 25 Gross GB PT G31 37MB 5 62 Nett BE FR I3B P G30 29MB 6 25 Gross DK FI IS G31 NL NO SE TECHNICAL SPECIFICATION MEDIUM INJECTOR SIZE NG 400 LPG 170 AERATION SIZE Ø NG 11mm Ø I2L 8mm Ø LPG 15 5 x 2 EFFICIENCY CLASS II FLUE T T B SENSOR 100oC FLUE OUTLET SIZE Ø 127mm INLET CONNECTION SIZE Ø 8mm 150 150 225 1007 127 50 470 1 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 176 ...

Страница 3: ...ING THE STOVE 4 1 Remove the ceramic coals and place on a dry clean surface Remove the front coal ceramic please handle with care 4 2 Clean the flame baffle ceramic piece and burner using a vacuum cleaner with soft brush attachment ensure all debris are removed from the burner ports 4 3 Replace the ceramics by referring to Section 5 5 ARRANGEMENT OF FUEL BED COM PONENTS The major ceramic component...

Страница 4: ...pondence always quote the appli ance type and the serial number which may be found on the data badge 9 ENAMEL CLEANING General cleaning must be carried out when the stove is cool If this stove is finished in a high gloss vitreous enamel to keep the enamel in the best condition observe the following tips 9 1 Wipe over daily with a soapy damp cloth followed by a polish with a clean dry duster 9 2 Fo...

Страница 5: ... that the local distribution conditions identification of the type of gas and pressure and the adjustment of the appliance are compati ble IMPORTANT ENSURE THAT THE APPLI ANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE REFER TO DATA BADGE AND TECHNI CAL SPECIFICATIONS AT THE FRONT OF THE BOOKLET FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 18...

Страница 6: ... expel any debris that may block the gas controls Connect the gas supply to the 8mm compression elbow at the right hand rear corner of the stove see Fig 10 6 4 Check the pull of the flue system by apply ing a lighted smoke pellet to the flue sys tem opening If there is a definite flow into the chimney proceed with the installation if not warm the chimney for a few minutes IF THERE IS STILL NO DEFI...

Страница 7: ...e isolation 6 device remove the door and place to one side carefully remove the ceramic fuelbed components 10 2 Undo the pilot compression nut remove the ignition lead from the electrode by gen tly pulling downwards and undo the ther mocouple from the back of the gas valve see Fig 19 Undo the main injector compression nut and pull pipe clear of the injector see Fig 23 10 3 Remove the two pozidriv ...

Страница 8: ...d in a restric tive location it may be necessary to remove the stove from its location 16 1 Locate the sensor in the draught diverter opening and gently pull the two wires off the terminals Undo the two taptite screws and remove the sensor and the two plastic spacers see Fig 24 16 2 Refit a new sensor ensuring that the spac ers are located between the sensor and the bracket replace the two leads 7...

Страница 9: ...has entered the stove pipework Blocked gas filter Replace filter refer to Section 12 Insufficient gas pressure Check the gas pressure and correct if necessary Empty supply tank or LPG only ensure adequate clylinder supply of gas in cylinders Short pilot flame length see Insufficient gas Check the gas pressure and diagram 26 pressure correct if necessary Blocked pilot flame Replace Unit refer to se...

Страница 10: ...ES YES YES NO NO NO NO YES YES YES YES NO FLAME FAILURE FUNCTIONAL CHECK PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE If the appliance goes out in use continually this may mean that the Waterford Flue T T B System has been activated The appliance should not be used until the cause has been found and rectified Ensure there is no debris around the pilot assembly e g coal soot etc which could shor...

Страница 11: ...A B Medium 1007 470 A 225mm B 150mm A 50mm B 150mm 10 DIAGRAMS Fig 7 Fig 8 Fig 9 ...

Страница 12: ...11 Fig 10 Fig 11 Fig 12 Fig 13 Fig 15 Fig 14 COAL LAYOUT ...

Страница 13: ...12 Fig 16 Fig 17 Fig 18 ...

Страница 14: ...13 Fig 19 Fig 21 Fig 20 ...

Страница 15: ...14 Fig 22 Fig 23 Fig 24 Fig 26 Fig 25 ...

Страница 16: ...he external surface of the wall 10 The flue should be capable of producing a continuous draught of between 0 06 w g during normal operation Location 1 Clearance to combustible materials must be adhered to as described in the Clearance to Combustibles section 2 The stove should be installed as to allow adequate air circulation around the stove and to allow access for installation servicing 3 The st...

Отзывы: