background image

15

TECHNICAL DATA

MANUFACTURED SMOKELESS
FUEL

WOOD

Max:  (kW)
Nominal:  (kW)

Room Water

Total

4.7kW

12.5 kW

17.2

3.6kW

12.3kW

15.9

Room Water

Total

3.8 kW

8 kW

11.8

3.5 kW

7.4kW

10.9

Typical refuelling intervals to obtain nominal
outputs:

MSF 2 

hours

WOOD .90 hrs

Flue Gas Mass Flow:

MSF

9.9 g/s

WOOD 10 g/s

Flue Gas Mass at nominal output:

372

o

C

258

o

C

Gross Weight:

200 kgs

Flue Outlet:

150mm

Flue Draught:

12 Pa

Boiler Tappings:

1” BSP

Max Water Pressure:

2 Bar

Efficiency:

76.3 %

76.8%

Model

Energy

Efficiency

Class

Heat Output

to Room

Heat Output

to Water

Energy

Efficiency

Index

Preferred

Fuel

Nominal

Heat

Output

Net Efficiency

Lismore

HPB SF

Stove

A

3.5

7.4

102.36

Wood

10.9

76.8

LIGHTING

Before lighting the stove check with the installer, that the installation work and commissioning checks
described previously have been carried out correctly and the chimney has been swept clean, is sound and
free from any obstructions. As part of the stove commissioning and handover the installer should demon-
strate how to operate the stove correctly.

Содержание Lismore

Страница 1: ...should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the boiler stove in situations where...

Страница 2: ...bles 11 16 Floor Protection 11 17 Plumbing 11 18 Pipe Thermostat 11 19 Regulations 11 20 Gravity Circuit 11 21 Injector Tee 12 22 Water Circuit Temperature 12 23 Flue Water Pipe Locations 13 24 Stove...

Страница 3: ...TABLE OF CONTENTS PAGE NO 43 Cleaning a Matt Black Senotherm Stove 18 44 Frozen System 18 45 Prolonged Periods of Non Use 19 46 Fire Safety 19 47 Glass Replacement 19 48 CO Alarm 19 49 Exploded View 2...

Страница 4: ...ed as per the requirements of the manual Failure to comply with the Installation requirements or Building Regulations will void your warranty Waterford Stanley reserve the right to replace any part du...

Страница 5: ...egulations to have a carbon monoxide alarm fitted to any room with a solid fuel appliance Location 10 Clearance to combustible materials must be adhered to as described in the Clearance to Combustible...

Страница 6: ...llow a build up of ashes in the ash pan as this will cause the grate to burn out prematurely Empty the ashpan when refuelling 7 Avoid slow burning of damp or unseasoned fuel as this will result in tar...

Страница 7: ...be done in accor dance with current Standards and Local Codes It should be noted that the requirements and these publications may be superseded during the life of this manual Please refer to the curr...

Страница 8: ...uld be at be at least 2300mm when measured horizontally and at least 1000mm when measured vertically see Fig 1 In circumstances where there are adjoining buildings structures roof openings there are a...

Страница 9: ...550mm per each kw of rated output above 5kw should be provided where a flue draught stabiliser is used the total free area shall be increased by 300mm for each kw of rated output 9 All materials used...

Страница 10: ...duct approval covers this appliance when installed in accordance with the manufactur er s instructions and relevant standards As there is currently no standard for Ducted Combustion Air Supply this do...

Страница 11: ...oking on refu elling See Fig 7 REGULATIONS The plumbing must be in accordance with all relevant regulations and practices It must include a gravity circuit with expansion pipe open to the atmosphere T...

Страница 12: ...id condensation on the boiler and return piping Fitting a pipe thermo stat to the flow pipe of the gravity circuit and wiring it into the pump control will ensure rapid circulation of the hot water In...

Страница 13: ...ly to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to use...

Страница 14: ...e a stove provides 2kW to the room and 8kW to the boiler and if the thermostatic damper shuts down the air supply to provide 4kW to the boiler then the heat to room will decrease pro portionally to 1k...

Страница 15: ...gs 1 BSP Max Water Pressure 2 Bar Efficiency 76 3 76 8 Model Energy Efficiency Class Heat Output to Room Heat Output to Water Energy Efficiency Index Preferred Fuel Nominal Heat Output Net Efficiency...

Страница 16: ...18 The hex head bolt should now be re inserted in the alternative position which will lock the grate in the wood burning position See Fig 16 USER INSTRUCTIONS Riddling Rod Wood Setting Fig 16 Fig 17 C...

Страница 17: ...the boiler cleaning plate The boiler cleaning plate can also be removed when cleaning the chimney if the flue pipe is fitted to the back outlet Fig 21 PERIODIC MAINTENANCE Adjusting the Door Catch Ove...

Страница 18: ...possibility that the water system may be frozen do not attempt to light the stove until you are certain there is no ice in the system possibly causing a blockage VITREOUS ENAMEL CLEANING General clean...

Страница 19: ...s and carefully remove the broken glass c Clean the glass recess in the door d Replace the sealing rope in the door if necessary e Tighten screws f Replace glass only with ceramic glass 5mm thick See...

Страница 20: ...THERMOSTAT G00479AXX 22 BADGE GASKET P00107AXX 23 GLASS CLIP GASKET P00117AXX 24 GLASS T00101AXX 25 PULL ROD KNOB U00001AXX 26 AIR CONTROL KNOB U00006AXX 27 SECONDARY AIR CONTROL U00018AXX 28 DOOR HAN...

Страница 21: ...NOTES 21...

Страница 22: ...NOTES 22...

Страница 23: ...NOTES 23...

Страница 24: ...24 Manufactured by Waterford Stanley Ltd Unit 401 403 IDA Industrial Estate Cork Road Waterford Ireland Tel 051 302300 Fax 051 302315 Item No N00524AXX Rev 005 YS280717...

Отзывы: