background image

3

16

11

12

13

14

15

FEATURES

 1.  Rubber Grip Handle

 2.  Pivoting LED  Area Light

 3.  Jump-Starter Power Switch

 4.  Backlit LCD Screen

 5.  USB Ports

 6.  Decrease Compressor Pressure Control Button (–)

 7.  Compressor Power Button

 8.  Increase Compressor Pressure Control Button (+)

 9.  Area Light Power Button

10.  USB Power Button

11.  Built-in 120 Volt AC Charger (under protective cover)

12.  Negative (–) Black Clamp

13.  Positive (+) Red Clamp

14.  Air Hose and Sure Fit® Nozzle

15.  Nozzle and Air Hose Storage

16.  Nozzle Adapter

17.  12V DC Charging Adapter (optional)

CARACTERÍSTICAS

 1.  Manija de goma

 2.  Lúz LED giratoria de área

 3.  Interruptor de encendido del puente auxiliar de arranque

 4.  Pantalla LCD retroiluminada

 5.  Puertos USB

 6.  Botón de disminución de control de presión del compresor (–)

 7.  Botón de alimentación del compresor

 8.  Botón para aumentar la presión del compresor (+)

 9.  Botón de encendido de la luz de área

10.  Botón de alimentación USB

11.  Cargador de CA de 120 voltios incorporado (bajo cubierta protectora)

12.  Pinza negra del negativo (–)

13.  Pinza roja del positivo (+)

14.  Manguera e boquilla  Sure Fit®

15.  Almacenamiento de boquilla y manguera de aire

16.  Adaptador de boquilla

17.  Adaptador de carga de CC (opcional)

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between equipment and receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.

Este dispositivo cumple con la parte 15 de las normas de la Comisión Federal de Comunicaciones de Estados Unidos (FCC). La operación está sujeta a las dos condiciones siguientes: (1) este dispositivo no puede causar 

interferencia perjudicial y (2) este mecanismo debe aceptar cualquier interferencia recibida, incluida la in-terferencia que puede provocar una operación no deseada.
Este equipo ha sido probado y se encontró que cumple con los límites para dispositivo digital Clase B, según la parte 15 de las normas de la FCC. Estos límites están diseñados para brindar protección razonable contra 

interferencia perjudicial en una instalación residencial. Este equipo genera, usa y puede irradiar energía en frecuencia de radio y, si no se instala y se usa de acuerdo con las instrucciones, puede provocar interferencia perjudicial 

en las comunicaciones de radio. Sin embargo, no hay garantía de que la interferencia no ocurra en una instalación en particular. Si el equipo provoca interferencia perjudicial en la recepción de radio o televisión, lo que se 

puede determinar al apagar y encender el equipo, el usuario debe tratar de corregir la interferencia mediante una o más de las siguientes medidas:

• Cambiar la orientación o la ubicación de la antena de recepción.

• Aumentar la separación entre el equipo y el receptor.

• Conectar el equipo a un tomacorriente sobre un circuito diferente de aquel al que está conectado el receptor.

• Consultar al vendedor o pedir la ayuda de un técnico en radio y televisión con experiencia.
Los cambios o las modificaciones no aprobados por el partido responsable de conformidad podían anular la autoridad del usuario para funcionar el equipo.

17

Содержание JUMP iT J5C09D

Страница 1: ...16 ...

Страница 2: ...L JUMPiT ENERGÍAPORTÁTIL MANUAL DE INSTRUCCIÓN SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS 2019 Baccus Global LLC Boca Raton FL 33432 877 571 2391 J5C09D English page 5 Español pagina 11 BC x ...

Страница 3: ...2 FEATURES CARACTERÍSTICAS 1 6 7 8 2 4 5 9 10 3 ...

Страница 4: ...sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a...

Страница 5: ... DE LA FUNCIÓN ALARM ICON ICONO DE ALARMA REVERSE POLARITY ICONS ICONOS DE POLARIDAD INVERSA CLAMP ICONS ICONOS DE PINZAS COMPRESSOR PRESSURE INDICATOR INDICADOR DE PRESIÓN DEL COMPRESOR USB ICON ICONO DE USB COMPRESSOR ICON ICONO DEL COMPRESOR JUMP STARTER ICON ICONO DEL PUENTE AUXILIAR DE ARRANQUE FAULT ICON ICONO DEL FALLO VOLTAGE INDICATOR INDICADOR DEL VOLTAJE ...

Страница 6: ...51 100 101 150 0 7 6m 7 6 15 2m 15 2 30 4m 30 4 45 7m 240V 0 50 51 100 101 200 201 300 0 15 2m 15 2 30 4m 30 4 60 9m 60 9 91 4m Ampere Rating Extension Cord Length More Not more 0 25 26 50 51 100 101 150 Than Than American Wire Gauge AWG 0 6 18 16 16 14 6 10 18 16 14 12 10 12 16 16 14 12 12 16 14 12 Not Recommended When an extension cord is used make sure that the pins of extension cord are the sa...

Страница 7: ... Starter Switch has been turned to the on position and the clamps are not connected to a battery refer to the Jump Starting Your Vehicle section a two second warning will sound every 10 seconds The backlit LCD screen will display the Battery Status Icon Battery Voltage Indicator the Clamp Icons and the and signs The Alarm Icon and the Jump Starter Icon will flash The unit remains on until the Jump...

Страница 8: ...xcept for positive grounded systems CAUTION TO REDUCE THE RISK OF PROPERTY DAMAGE Vehicles that have on board computerized systems may be damaged if vehicle battery is jump started Before jump starting this type of vehicle read the vehicle manual to confirm that external starting assistance is advised Excessive engine cranking can damage the vehicle s starter motor If the engine fails to start aft...

Страница 9: ...attery should last the service life of the unit Service life is dependent on a number of factors including but not limited to the number of recharge cycles and proper care and maintenance of the battery by the end user Contact manufacturer for any information you may need SAFE BATTERY DISPOSAL Contains a maintenance free sealed non spillable lead acid battery which must be disposed of properly Rec...

Страница 10: ... 60Hz 13W Area Light 1 white LED USB Ports 3 1A max 5V DC Compressor Maximum Pressure 120 PSI JUMP iT and Sure Fit are registered U S trademarks owned or licensed by Baccus Global LLC Imported by Baccus Global LLC One City Centre 1 North Federal Highway Suite 200 Boca Raton FL 33432 www Baccusglobal com 1 877 571 2391 RD051519 ...

Страница 11: ...10 ...

Страница 12: ...ría muestre 4 barras sólidas antes de usarlo por primera vez No se puede exceso de carga la unidad con el método de carga de CA Para recargar esta unidad utilice sólo el cargador incorporado CA Todas las funciones deben apagarse cuando la unidad se está cargando o no está en uso Asegúrese de que todos los interruptores estén en la posición de apagado OFF antes de realizar la conexión a una fuente ...

Страница 13: ...retroiluminada PRIMEROS AUXILIOS Cuando trabaje con baterías de plomo ácido asegúrese de que siempre haya ayuda inmediata disponible en caso de accidente o emergencia Utilice siempre protección para los ojos al emplear este producto el contacto con el ácido de la batería puede producir ceguera o quemaduras graves Conozca los procedimientos de primeros auxilios para el caso de contacto accidental c...

Страница 14: ...egra del negativo al bastidor o a un componente metálico no móvil y sólido o una parte de la carrocería Nunca fije la pinza directamente al terminal del negativo de la batería o a una pieza móvil Refiera al manual del dueño del automóvil 5 Procedimiento para arrancar SISTEMAS CON POSITIVO A TIERRA Nota En el caso poco habitual de que el vehículo que se debe arrancar tenga un sistema de positivo a ...

Страница 15: ... sección de las instrucciones de seguridad específicas para compresores de este manual de la instrucción PRECAUCIÓN PARA REDUCIR EL RIESGO DE DAÑOS MATERIALES Cuando el compresor es operado a un PSI baja la unidad puede comenzar en baja y acelerar gradualmente Cuando el compresor es operado a más alto PSIs la unidad puede funcionar normalmente durante varios minutos luego decelerar durante unos mi...

Страница 16: ...encendido del compresor para apagar el compresor Reinicie después de un período de enfriamiento de 30 minutos aproximadamente Compruebe que la unidad tiene una carga completa Recargue la unidad en caso de necesidad ACCESORIOS Accesorios recomendados para uso con esta unidad puede ser disponibles a través del fabricante Si necesita ayuda con respecto a los accesorios por favor póngase en contacto c...

Отзывы: