HOSE TYPES

The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy-

draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with 

Stanley Hydraulic Tools. They are:

Certified non-conductive

 — constructed of thermoplastic or synthetic rubber inner tube, synthetic fiber braid 

reinforcement,  and  weather  resistant  thermoplastic  or  synthetic  rubber  cover. 

Hose labeled 

certified  non-

conductive

 is the only hose authorized for use near electrical conductors.

Wire-braided

 (conductive) — constructed of synthetic rubber inner tube, single or double wire braid reinforce-

ment, and weather resistant synthetic rubber cover. 

This hose is 

conductive

 and must never be used near 

electrical conductors.

Fabric-braided

 (not certified or labeled non-conductive) — constructed of thermoplastic or synthetic rubber in-

ner tube, synthetic fiber braid reinforcement, and weather resistant thermoplastic or synthetic rubber cover. 

This 

hose is 

not certified non-conductive

 and must never be used near electrical conductors.

HOSE SAFETY TAGS

To help ensure your safety, the following DANGER tags are attached to all hose purchased from Stanley Hydraulic 

tools. DO NOT REMOVE THESE TAGS.
If the information on a tag is illegible because of wear or damage, replace the tag immediately. A new tag may be 

obtained from your Stanley Distributor.

THE TAG SHOWN BELOW IS ATTACHED TO “CERTIFIED NON-CONDUCTIVE” HOSE

THE TAG SHOWN BELOW IS ATTACHED TO “CONDUCTIVE” HOSE.

(Shown smaller than actual size)

SIDE 1

D A N G E R

1. 

FAILURE TO USE HYDRAULIC HOSE LABELED AND CERTIFIED AS NON-CONDUCTIVE 

WHEN  USING  HYDRAULIC TOOLS  ON  OR  NEAR  ELECTRIC  LINES  MAY  RESULT  IN 

DEATH OR SERIOUS INJURY.
FOR  PROPER AND  SAFE  OPERATION  MAKE  SURE THAT YOU  HAVE  BEEN  PROP-

ERLY TRAINED IN CORRECT PROCEDURES REQUIRED FOR WORK ON OR AROUND 

ELECTRIC LINES.

2. 

BEFORE USING HYDRAULIC HOSE LABELED AND CERTIFIED AS NON-CONDUCTIVE 

ON OR NEAR ELECTRIC LINES. WIPE THE ENTIRE LENGTH OF THE HOSE AND FIT-

TING WITH A CLEAN DRY ABSORBENT CLOTH TO REMOVE DIRT AND MOISTURE AND 

TEST HOSE FOR MAXIMUM ALLOWABLE CURRENT LEAKAGE IN ACCORDANCE WITH 

SAFETY DEPARTMENT INSTRUCTIONS.

SEE OTHER SIDE

SIDE 2

DO NOT REMOVE THIS TAG

3. 

DO NOT

  EXCEED  HOSE  WORKING  PRESSURE  OR ABUSE  HOSE.  IMPROPER  USE 

OR  HANDLING  OF  HOSE  COULD  RESULT  IN  BURST  OR  OTHER  HOSE  FAILURE. 

KEEP HOSE AS FAR AWAY AS POSSIBLE FROM BODY AND

 DO NOT

 PERMIT DIRECT 

CONTACT  DURING  USE.  CONTACT AT THE  BURST  CAN  CAUSE  BODILY  INJECTION 

AND SEVERE PERSONAL INJURY.

4. 

HANDLE AND ROUTE HOSE CAREFULLY TO AVOID KINKING, ABRASION, CUTTING, OR 

CONTACT WITH HIGH TEMPERATURE SURFACES. 

DO NOT

 USE IF KINKED. 

DO NOT

 

USE HOSE TO PULL OR LIFT TOOLS, POWER UNITS, ETC.

5. 

CHECK  ENTIRE  HOSE  FOR  CUTS  CRACKS  LEAKS ABRASIONS,  BULGES,  OR  DAM-

AGE TO  COUPLINGS  IF ANY  OF THESE  CONDITIONS  EXIST,  REPLACE THE  HOSE 

IMMEDIATELY. NEVER USE TAPE OR ANY DEVICE TO ATTEMPT TO MEND THE HOSE.

6. 

AFTER EACH USE STORE IN A CLEAN DRY AREA.

SEE OTHER SIDE

D A N G E R

DO NOT REMOVE THIS TAG

D A N G E R

(Shown smaller than actual size)

SIDE 2

5. 

CHECK ENTIRE HOSE FOR CUTS CRACKS LEAKS ABRASIONS, BULGES, OR DAMAGE TO 

COUPLINGS IF ANY OF THESE CONDITIONS EXIST, REPLACE THE HOSE IMMEDIATELY. 

NEVER USE TAPE OR ANY DEVICE TO ATTEMPT TO MEND THE HOSE.

6. 

AFTER EACH USE STORE IN A CLEAN DRY AREA.

D A N G E R

DO NOT REMOVE THIS TAG

D A N G E R

SIDE 1

1. 

DO  NOT  USE THIS  HYDRAULIC  HOSE  ON  OR  NEAR  ELECTRIC  LINES. THIS  HOSE  IS 

NOT LABELED OR CERTIFIED AS NON-CONDUCTIVE. USING THIS HOSE ON OR NEAR 

ELECTRICAL LINES MAY RESULT IN DEATH OR SERIOUS INJURY.

2. 

FOR PROPER AND SAFE OPERATION MAKE SURE THAT YOU HAVE BEEN PROPERLY 

TRAINED IN CORRECT PROCEDURES REQUIRED FOR WORK ON OR AROUND ELEC-

TRIC LINES.

3. 

DO NOT

 EXCEED HOSE WORKING PRESSURE OR ABUSE HOSE. IMPROPER USE OR 

HANDLING OF HOSE COULD RESULT IN BURST OR OTHER HOSE FAILURE. KEEP HOSE 

AS  FAR AWAY AS  POSSIBLE  FROM  BODY AND

 DO NOT

  PERMIT  DIRECT  CONTACT 

DURING USE. CONTACT AT THE BURST CAN CAUSE BODILY INJECTION AND SEVERE 

PERSONAL INJURY.

4. 

HANDLE AND ROUTE HOSE CAREFULLY TO AVOID KINKING, CUTTING, OR CONTACT 

WITH HIGH TEMPERATURE SURFACES. 

DO NOT

 USE IF KINKED. 

DO NOT

 USE HOSE TO 

PULL OR LIFT TOOLS, POWER UNITS, ETC.

DO NOT REMOVE THIS TAG

D A N G E R

SEE OTHER SIDE

SEE OTHER SIDE

Содержание GPV13

Страница 1: ...73417 1 2014 Ver 1 GPV13 V SERIES HYDRAULIC POWER UNIT USER MANUAL Safety Operation and Maintenance...

Страница 2: ...2 GPV13 User Manual...

Страница 3: ...nd for information on your warranty visit Stanleyhydraulic com and select the Warranty tab NOTE The warranty recording form must be submitted to validate the warranty SAFETY SYMBOLS 4 SAFETY PRECAUTIO...

Страница 4: ...s that follow this symbol to avoid possible injury or death DANGER This safety alert and signal word indicate an imminently hazardous situation which if not avoided will result in death or serious inj...

Страница 5: ...safety factor Be sure all hose con nections are tight Be sure all hoses are connected for correct flow di rection to and from the tool being used Do not inspect hoses and fittings for leaks by using b...

Страница 6: ...6 GPV13 User Manual TOOL STICKERS TAGS GPV13 Hydraulic Power Pack Safety Tag wire tied to power unit...

Страница 7: ...CLEAN DRY ABSORBENT CLOTH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUM ALLOWABLE CURRENT LEAKAGE IN ACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E...

Страница 8: ...ressure 2500 175 1 25 4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 Ty...

Страница 9: ...pm 7 9 gpm 9 10 5 gpm 11 13 gpm 15 23 lpm 26 34 lpm 34 40 lpm 42 49 lpm 1500 psi 1500 psi 1500 psi 1500 psi 103 bar 103 bar 103 bar 103 bar 2100 2250 psi 2100 2250 psi 2200 2300 psi 2100 2250 psi 145...

Страница 10: ...ut and resist biologi cal growth that may occur in cool operating hydraulic circuits These fluids are recommended by Stanley Hy draulic Tools Other fluids that meet or exceed the speci fications of th...

Страница 11: ...138B02 One hydraulic tool can be connected to the tool circuit The circuit is activated by moving the control lever on the power unit to the ON position THROTTLE CONTROL The power unit is equipped wit...

Страница 12: ...he engine is hot Do not fill the fuel tank to a point of overflowing Shown above Figure 5 are the Honda and Briggs pri mary engine components referred to in this section Be come familiar with these co...

Страница 13: ...ntly 9 After the engine starts allow it to warm up Gradu ally adjust the choke until it is in the open position 10 Connect hoses and the tool as described on pages 7 and 8 11 Move the tool circuit con...

Страница 14: ...enance and op eration manual furnished with the power unit Also see maintenance schedule on pages 15 16 HYDRAULIC SYSTEM MAINTENANCE Check hydraulic fluid level daily Add fluid per speci fications in...

Страница 15: ...ce if Necessary Hydraulic Fluid Level Check Hydraulic Fluid Replace Every 200 hours Remove Condensed Moisture Check For Leaks Kinks etc Hydraulic Fluid Filter Replace Hyd Fluid Cooler Inspect Clean as...

Страница 16: ...ystem Clean Spark Plugs Clean Readjust Finger Guard Clean Muffler Controls Clean Hydraulic Fluid Level Check Hydraulic Fluid Replace Every 200 hours Remove Condensed Moisture Check For Leaks Kinks etc...

Страница 17: ...clock wise 4 Start the engine and allow it to run until warm 5 With the engine at full operating speed the test flow gauge should read 4 6 gpm 15 23 lpm on GPV135H02 or 7 9 gpm 26 34 lpm on GPV138B02...

Страница 18: ...tool and back to the right fitting return Fluid always flows from the male to female fittings Quick disconnect fittings defective Detach from hose connect set together and check for free flow Hydrauli...

Страница 19: ...15 2000 psi 70 140 bar Length GPV135H02 and GPV138B02 780 mm 30 7 in Width GPV135H02 and GPV138B02 510 mm 20 1 in Height GPV135H02 and GPV138B02 600 mm 23 6 in Weight GPV135H02 and GPV138B02 75 kg 166...

Страница 20: ...Technology Development Co Ltd Add A 7 Building Gongtou Liheng Industry Square Western Section Fanhua Street the Cross Wenshan Road Hefei Anhui China Tel 0551 63498781 2 3 Fax 0551 63498780 P C 230601...