Operation
Stanley TLM 300 1.0.0 gb
Measure with offset
An offset automatically adds or subtracts a value to/
from ALL measurements. With this feature toler-
ances can be taken into consideration e.g. between
unfinished and finished dimensions.
Select the menu function
OFFSET
{
C, 19
} , confirm
with the
EQUAL
- key {
A, 8
}. Adjust the OFFSET with
the
PLUS
- key {
A, 7
} or the
MINUS
- key {
A, 12
}.
By holding the keys down, the setting values will
increase/decrease faster. Once you have entered the
proper offset confirm your selection with the
EQUAL
- key {
A, 8
}.
As long as an
OFFSET
{
C, 19
} is added/subtracted
the symbol is visible on the display.
Laser in continuous operation
The laser continuous operation activates the laser
permanently.
Press
MENU
- key {
A, 9
} briefly to select desired
LASER
setting.
)
Default setting: LASER continuous operation
OFF.
Reset
When you select the menu function
RESET
(
RESET
will blink in the display) and press the
EQUAL
-key
{
A, 8
} the device will default to factory settings.
CAUTION:
Any customized presettings as well as
stored values will be deleted.
Operation
Switching On/Off
ON:
Press
ON
- key {
A, 1
} briefly. The laser is
active. Battery indication is displayed until the
next keystroke.
OFF:
Press and hold
OFF
- key {
A, 11
}. To maxi-
mize battery life the laser beam will switch off
after 90 seconds of inactivity, the device will
automatically switch off after 3 minutes of
inactivity.
CLEAR key
Pushing the
CLEAR
- key {
A, 11
} clears the last entry
or measurement. Within a function (area, volume,
etc.) single measurements can be deleted step by
step and remeasured.
Reference setting
If the positioning bracket is folded out, the device
recognizes the position, adapts the reference and
calculates distances accordingly.
The default reference setting is from the rear of the
instrument. By pressing the
REFERENCE
- key {
A, 2
},
the setting can be changed, so that the next
measurement taken will be from the "front" of the in-
strument.
Afterwards the reference setting automatically
defaults back to rear. See picture {
G
}.
Содержание FatMax TruLaser TLM 300
Страница 1: ...1 77 930 77 930...
Страница 5: ......
Страница 17: ......
Страница 39: ......
Страница 61: ......
Страница 73: ......
Страница 142: ...D GB F I E P NL DK S N FIN J CN ROK PL HR H RUS CZ GR 1 Stanley TLM 300 1 0 0 rok 1 0 TLM 300 1 3 4 5 5 8 B C 20 D F D F...
Страница 163: ......
Страница 212: ...D GB F I E P NL DK S N FIN J CN ROK PL HR H RUS CZ GR 7 Stanley TLM 300 1 0 0 gr A 1 2 I A 13 3 J A 13 3 K A 13 L A 1...
Страница 217: ......
Страница 218: ......
Страница 219: ......
Страница 220: ...L C A 7 4 6 6 5 4 L C A 7 4 6 6 5 4...