8
Resistor
Range
Resolution
Accuracy
200Ω
0.1Ω
±1.2% of reading, ±5 digits
2kΩ
1Ω
±0.8% of reading, ±2 digits
20kΩ
10Ω
±0.8% of reading, ±2 digits
200kΩ
100Ω
±0.8% of reading, ±2 digits
2MΩ
1kΩ
±1.0% of reading, ±5 digits
Maximum open circuit voltage: 2.4V
Overload protection: 250V DC or RMS. AC
Diode and circuit on-off measurement
Range
Description
When the on-resistance is smaller than 30Ω,
the built-in buzzer will beep.
Displays the approximate diode positive voltage.
Overload protection: 250V DC or RMS. AC
Battery voltage measurement
Position
Resolution
Load impedance
1.5V
0.001V
470
9V
0.01V
3000
Overload protection: F2:FF 400mA H 600V,10KA
Operating Instructions
Notices before operation:
1
Plug the instrument in, check the batteries, if it is low, the
symbol “
” will display, requiring battery replacement;
otherwise follow the steps below.
User Manual