EPX10
User
Manual ◄ 9
• Connect the brazing gun, power and trigger cable to the unit.
• Connect the ground device to the unit, if not already connected.
• Press on/off button and select the right pin type by pressing the ”setting” button.
The unit will remember what setting was used last.
• Load the gun with brazing pin and ferrule, if not already loaded.
ON / OFF
Fuse for electronics
Selected setting
Pin setting
Battery Indicator
Grinding / charging
Ground
Fuse for grinding
/ charge
Gun power
Gun control
Error Indication
Make sure to braze in the top of the hole when
brazing to a vertical surface.
• Hold the gun firmly with both hands against the work
piece and pull the trigger just once.
• The electronic unit will by itself finish the brazing pro
-
cess.
• Hold the gun in place for 3-4 seconds after the braz-
ing is complete to allow for cooling.
• Remove the gun straight backwards without pulling
the trigger!
• Knock off the shank of the brazing pin with a ham-
mer.
• The brazing is completed.
PIN BRAZE
NOTE:
If the brazing is aborted to early “ERROR” will turn on.
The brazing should be redone for a good result.
The error lamp will turn off after 8 seconds
Use a new ceramic ring for each new pin braze.
The battery indicator “LOW BATT” flashes when
the batteries are almost discharged,
when the “LOW BATT” is constantly lit the batter-
ies are discharged and you can’t do
any more pin brazing. Charge the battery.
NOTICE
OPERATION