background image

EPX10 

User

 Manual ◄ 7

GENERAL PROTECTION

Store the Electronic Pin Brazing Unit in a place where it is 

protected from the elements, abrasive dust, and damage.  

Use only recommended repair and replacement parts and 

materials specified in this manual. 

Use  only  recommended  accessories  also  specified  in  the 

this manual. 

Do not use the Electronic Pin Brazer for applications it was 

not designed for.

Use the carrying handle to transport the unit from location 

to location.  

CLEANING

Establish a routine to keep the unit as free from dirt as pos-

sible – daily, or at each shift change, for example.

Pin Brazers exposed to rain, sand, or grit-laden air should be 

cleaned prior to each use.

Keep tool labels and stickers legible.

PREOPERATION PROCEDURES

Before putting a new ECONECT Pin Brazing unit into initial 

service, or after an extended period of being unused, perform 

a visual inspection for bent, broken, cracked, missing or worn 

components.  

INITIAL SETUP AND BATTERY CHARGING

WARNING

Failure to follow the instructions in the battery charger 

operation manual can result in battery explosion and 

serious bodily injury. To reduce the risk of battery ex-

plosion, read and understand the safety and operation 

instructions in the battery charger operation manual,  

the instructions published by the battery manufacturer, 

and the instructions in this manual before attempting to 

charge the batteries. 

PREOPERATION

Содержание EPX10

Страница 1: ...2013 Stanley Black Decker Inc New Britain CT 06053 U S A 73157 2 2015 Ver 6 Safety Operation and Maintenance USER MANUAL EPX10 PIN BRAZING UNIT...

Страница 2: ...serie del equipo Matricola dell attrezzatura All Has been manufactured in conformity with Wurde hergestellt in bereinstimmung mit Est fabriqu conform ment Ha sido fabricado de acuerdo con E stata cost...

Страница 3: ...THE IMPROPER REPAIR OR SERVICE OF THIS TOOL REPAIRS AND OR SERVICE TO THIS TOOL MUST ONLY BE DONE BY AN AUTHORIZED AND CERTIFIED DEALER WARNING DECLARATION OF CONFORMITY 2 SAFETY SYMBOLS 4 SAFETY PRE...

Страница 4: ...his symbol to avoid possible injury or death DANGER This safety alert and signal word indicate an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Thi...

Страница 5: ...under the supervision of an instructor Always wear safety equipment such as goggles ear head protection and respiratory protection at all times when operating the tool Do not inspect or clean the too...

Страница 6: ...harged after about 4 hours if completely discharged CHARGING THE BATTERY CAN ONLY BE CARRIED OUT BETWEEN 0 C to 45 C NOTICE If the batteries are left uncharged they may be damaged CAUTION Battery char...

Страница 7: ...exposed to rain sand or grit laden air should be cleaned prior to each use Keep tool labels and stickers legible PREOPERATION PROCEDURES Before putting a new ECONECT Pin Brazing unit into initial ser...

Страница 8: ...o the twist lock receptacle in the Econect unit marked GROUND and twist to lock SELECT PINS AND RINGS 4 Select brazing pins and ceramic rings to match the speci fications of the bonding cable you sele...

Страница 9: ...mly with both hands against the work piece and pull the trigger just once The electronic unit will by itself finish the brazing pro cess Hold the gun in place for 3 4 seconds after the braz ing is com...

Страница 10: ...from oxidation Keep them free from contamination like Grease oil Make sure they are not damaged SETTING RIGHT LIFT HEIGHT The S15 brazing gun self adjust to the same lift height every time See separa...

Страница 11: ...R Press and hold the SETTING button while you push the ON OFF button LOW BATTERY LED will light Release the buttons The LEDs on the front panel show the charge status of battery 2 LIFTING HEIGHT CONTR...

Страница 12: ...never twist the main shaft when mounting the pinholder When loading the brazing pin it should not go in loose into the pinholder if it does push the pinholder together with your fingers to gain a tigh...

Страница 13: ...hen LOW BATTERY is lit release buttons Press SETTING and the leds will start to blink In this mode the unit is able to check the lift height Important Press the tool completely against the gun then pu...

Страница 14: ...PORTANT never adjust in the hole where the big plug is 4 When liftheight is too low Use the 3mm hexagon allen wrench and adjust the screw in the small hole counter clockwise about 1 4 of a turn then c...

Страница 15: ...ries ERROR Led is lit after a braze The pin brazing was not complete Action The braze should be remade to achieve good results The Led turns off after 8 seconds ERROR Led glows Failure of a sensor in...

Страница 16: ...le Lug for 16 mm Cable 35835 47527 Cable Lug for 25 mm Cable 35836 47528 Cable Lug for 35 mm Cable 35836 47529 Cable Lug for 50 mm Cable 35836 47522 Cable Lug 5 8 ground rod to 2 cable 2 x 35836 47521...

Страница 17: ...35835 41225 Bond Wire 34 Long C L C L W 9 mm eyelets on 35835 both ends 41226 Bond Wire 46 Long C L C L W 9 mm eyelets on 35835 both ends 66579 25mm2 x 500mm Extension Bond 35835 66580 25mm2 x 900mm...

Страница 18: ...972 Charger 36 V 110 V ECONECT 73077 Econect Battery Kit GRINDER Part No Qty Description HGE12141 Cordless Grinder Includes Grinder Only NO Battery or Charger HGE12151 Cordless Grinder Kit Includes Gr...

Страница 19: ...Safebond EPX10200 Econect Unit HGE12151 Grinder Elec Cordless Kit 72972 Charger 36V 110V Econect 72973 Carrying Strap and 72974 Carrying Case 73358 Carbide Burr EPX10040 Econect Kit Includes BG10600 S...

Страница 20: ...20 EPX10 User Manual EPX10 PARTS ILLUSTRATION ECONECT Part Sheet Q1 6 D1 6 R5 K1 M1 C1 C2 F1 L1 BT1 AND R4 F4 R3 FRONT PANEL S1 S2 J4 J5 J3 J2 F3 F2...

Страница 21: ...d complete 1 R5 Shunt 150A 6 Q1 Q6 Mosfet 6 D1 D6 Diode 1 L1 Triode 2 C1 C2 Capacitor 1 M1 Fan 1 Front panel 1 J3 Wall socket 4 pin 1 J4 Wall socket 5 pin 1 J2 Wall socket for ground female 1 J1 Wall...

Страница 22: ...3 Gate 4 Gate 5 Gate 6 S L d volt IN GUN GND VCC TRIG ON OFF SETTING TEMP 1 TEMP 2 TEMP 3 FrontLED SHUNT SHUNT HEAT FAN K1 Econect styrkort GUN GUN CONTROL 5A GRINDER 15A GRINDER CHARGING ON OFF SETT...

Страница 23: ...istor 22Ohm 4W 2 x Plastic washer 3 x Cable ties The kit P N 73720 and steps 1 thru 19 listed below applies only to units S N 1215090 and below For Units S N 1215091 and Up See part number 73077 1 Rem...

Страница 24: ...emove the batteries positive cable also remove the bolt and fuse Be careful so the cables don t come in contact with any other parts in the unit 6 Directly after disconnecting the positive cable it mu...

Страница 25: ...ries negative cable from the current shunt 10 Pull out the cable 11 Pull out the black cables connector form the top socket TEMP1 and the blue cables connector form the bottom socket TEMP3 12 Remove t...

Страница 26: ...necting the cables in the reversed order start from step 12 up to step 8 16 WARNING RISK FOR SHORT CIRCUIT Mount the M8 bolt with a plastic washer on the copper rail Before the battery is connected th...

Страница 27: ...fuse and batteries positive cable on the bolt 18 Mount the positive cable for the electronics and a plastic washer 19 Mount the washer and lock nut and tighten Don t tighten too hard the plastic washe...

Страница 28: ...Stanley Hydraulic Tools 3810 SE Naef Road Milwaukie Oregon 97267 5698 USA 503 659 5660 Fax 503 652 1780 www stanleyhydraulics com...

Отзывы: