background image

Stanley Access Technologies

Quick-Reference Guide

ECO Pro™

Retrofit and New Installation Instructions

204082

Rev. B 10/11/2012

Prohibition on Copying

Any unauthorized reproductions, disclosure or distribution of copies by any person of any portion of this work may be a violation 

of copyright law of the United States of America and other countries, could result in the awarding of statutory damages of up to 

$250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.  All rights reserved.

© 2012, STANLEY BLACK & DECKER. ALL RIGHTS RESERVED.

Purpose:

The ECO Pro replaces the conventional function switch and provides advanced user-defined automatic 

scheduling options, basic troubleshooting instructions, and door performance and history.  It is intended to 

provide an integrated means for two way communication between the door system and the user.

204082

Rev B 10/11/2012

Page 1 of 12

Note:

This may be in the general or same 

location as the typical rotary switch

2.3 

Attach Mounting Plate

2.3.1  Determine customer-

 

preferred orientation of 

 

mounting plate.  Refer 

 

to Figures 2a & 2b for 

 

orientation options.

2.3.2  If necessary, use 

 

Mounting Plate as a 

 

template.  Refer to 

 

Attachment 2, 

 

Machining Diagram for 

 

additional information.

2.3.3  Attach using # 8-18 x    

 

1/2” screws, provided.

Figure 2a.  Mounting Toward 

the Door System

2.1 

Connect Wiring Harness to Controller

 

2.1.1  Open the header and Refer to 

 

 

Attachment 1 “ECO Pro Wiring 

 

 

Diagram.”

 

2.1.2  Connect wiring harness to TB7 

 

 

on MC521 Pro Controller.

2.2 

Route Wiring Harness

 

2.2.1  Route harness across header

 

 

using best practices and through  

 

 

the jamb to cable access hole.

2. 

Install the ECO Pro

1.   

Prerequisites

 

1.1 

Door system installation instructions

 

1.2 

Stanley document #204066 MC521 Pro  

 

 

Installation Instructions

 

1.3 

Wiring for MC521 Pro is complete    

 

1.4  

FIS is performed or controller is showing

 

 

“A1”

LCD

HOME 

SCREEN*

ARROW 

DOWN

ARROW 

UP

INDICATOR 

LIGHTS

MENU**

** MUST BE HELD 

FOR 2 SECONDS TO 

ACTIVATE

SELECT

FACE PLATE

MOUNTING 

PLATE

Figure 1. ECO Pro

Figure 2b.  Mounting Away 

from the Door System

Содержание ECO Pro

Страница 1: ...ounting Plate 2 3 1 Determine customer preferred orientation of mounting plate Refer to Figures 2a 2b for orientation options 2 3 2 If necessary use Mounting Plate as a template Refer to Attachment 2...

Страница 2: ...cked 2 5 2 Turn off power 2 6 Attach ECO Pro Face Plate 2 6 1 Refer to Figure 4 Using the 6 20 X 5 8 screws provided attach ECO Pro face plate to mounting plate 2 6 2 Feed unused wiring length into th...

Страница 3: ...act 3 2 2 Enter the key sequence as follows Hold Menu button 1 and Press Down Arrow 2 and RELEASE both buttons Then hold Select 3 and Press Up Arrow 4 and RELEASE both buttons Note 1 This is a menu in...

Страница 4: ...ally saved to memory PRESS PRESS SEE Door ID ANNNNN END 3 3 1 From the Service Menu arrow to MC521 Control and press Select 3 3 2 Arrow up to Function Sw Software and press Select to save 3 3 Enable E...

Страница 5: ...UCED Start Up Mode REDUCED ONEWAY 4 or 6 Position Switch Only 6 Position Switch Only END OR OR OR OR Start Up Mode CLOSED OR 3 7 Change Support Contact Information if necessary 3 4 1 From Service Menu...

Страница 6: ...ss Select to save 4 3 1 Set Closed Mode Closed Mode programs the door operating mode to enable Oneway once Closed Locked is selected The door operating mode switches to proper Closed Locked once the d...

Страница 7: ...the Function Menu arrow to Traffic Sense and press Select Arrow to either Enabled or Disabled and press Select to save 4 3 2 Set Hold Open Mode Hold Open Mode allows for ECO Pro to use two different...

Страница 8: ...ess hole and the mounting holes for the screws 3 Mark punch the mounting screw locations 4 Cut a 1 250 hole using a hole saw 5 Using a 26 drill bit 147 dia drill the 2 holes for the mounting screws No...

Страница 9: ...3 2 9 Set Traffic Sense Option Default Traffic Sense is Off 4 3 3 10 Perform ECO Pro Closeout Procedure 5 ECO Pro Service Checklist Step Action Reference Section Complete 1 Review Error History From M...

Страница 10: ...be used with access control systems by connecting the activation output of the access control system to the hold open input of the MC521 Pro TB2 1 to TB2 2 In this way the ECO Pro can automatically s...

Страница 11: ...T indicates the door is functioning properly A flashing RED LIGHT indicates the door is not functioning properly The LCD HOME SCREEN displays the operating mode alerts instructions to correct alerts a...

Страница 12: ...This page left intentionally blank 204082 Rev B 10 11 2012 Page 12 of 12 2012 STANLEY BLACK DECKER ALL RIGHTS RESERVED...