6.3 Safety valve (ref. 10)
The safety valve has been set for the highest
permitted pressure of the pressure vessel. It is
prohibited to adjust the safety valve or remove its
seal. Actuate the safety valve from time to time to
ensure that it works when required. Pull the ring with
sufficient force until you can hear the compressed
air being released. Then release the ring again.
6.4 Storage
Warning!
Pull the mains plug out of the socket and
ventilate the appliance and all connected
pneumatic tools.
Switch off the compressor and make sure that it
is secured in such a way that it cannot be started
up again by any unauthorized person.
Warning!
Store the compressor only in a dry location which
is not accessible to unauthorized persons.
Always store upright, never tilted!
7. DISPOSAL AND RECYCLING
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local
council.
8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
CAUSE
REMEDY
Leakage of air from the valve
of the pressure switch with
the compressor off.
Check valve that, due to wear
or dirt on the seal, does not
perform its function correctly.
Unscrew the hexagonal head
of the check valve, clean the
valve seat and the special
rubber disk (replace if worn).
Reassemble and tighten
carefully.
Reduction of performance.
Frequent start-up. Low
pressure values.
Excessive performance
request, check for any leaks
from the couplings and/or
pipes. Intake filter may be
clogged.
Replace the seals of the
fitting, clean or replace the
filter.
The compressor stops and
restarts automatically after a
few minutes.
Tripping of the thermal cutout
due to overheating of the
motor.
Clean the air ducts in the
conveyor. Ventilate the work
area.
After a few attempts to
restart, the compressor.
Tripping of the thermal cutout
due to overheating of the
motor (removal of the plug
with the compressor running,
low power voltage).
Activate the on/off switch.
Ventilate the work area.
Wait a few minutes. The
compressor will restart
independently.
The compressor does not
stop and the safety valve is
tripped.
Irregular functioning of the
compressor or breakage of
the pressure switch.
Remove the plug and contact
the Service Center.
Any other type of operation must be carried out by authorized Service Centers, requesting
original parts. Tampering with the machine may impair its safety and in any case make the
warranty null and void.
Содержание D 200/10/24
Страница 6: ...6 1a 1b 9 2 5 7 1 1 11 9 4 2 11 10 5 7 D 200 8 24 D 200 10 24 D 200 8 6 6 12 4 6 3...
Страница 8: ...8 5a 5b 4 15 17 4 D 200 8 24 D 200 10 24 D 200 8 6 17 16...
Страница 58: ...58 R U S 1 4 m 20 dB 5 C 40 C 4 5 1 5 2...
Страница 59: ...59 R U S 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 3 4 5 C 40 C S3 25 2 5 7 5 5 4 D 200 8 6...
Страница 61: ...61 R U S 6 2 11 6 3 10 6 4 7 100 100...
Страница 62: ...62 R U S 8...