FLUES
The chimney and flue pipes intended for use with
this appliance should be mechanically robust, resist-
ant to internal and external corrosion, non-com-
bustible, and durable under the conditions to which
they are likely to be subjected.
Flues require a suitable external terminal which
should be designed to permit the easy exit of com-
bustion products whilst providing protection against
the ingress of rain, birds and other foreign matter
into the system. Flue pipes and accessories such
as clips and stays should not be made of unprotect-
ed mild steel or other material which is likely to cor-
rode.
Where flue piping passes through a closure plate
with a sliding door, ensure that the pipe continues
up and is ultimately connected to the flue liner and
well sealed with fire cement.
Do not connect to a chimney serving another appli-
ance. Chimneys wholly constructed of single skin
pipe are not recommended under any circum-
stances. Due to their inability to retain heat such
chimneys will inevitably give rise to the formation of
condensation.
The outlet on the appliance is 6” (150mm) diameter.
The proudct is supplied with a reducer to reduce the
diameter of the chimney/flue form 6” (150mm) to the
required 5” (125mm). If using enamelled pipes or
bends it is permitted to use 6” (150mm) diameter up
to a length of 6ft (1.8 meter) from the outlet of the
Fig. 10
PRE-INSTALLATION CHECK
Before installing your cooker, check that the chim-
ney is clean and clear of obstructions. Cracked
brickwork and leaking joints should be made good.
IT IS RECOMMENDED TO CONNECT TO A FLUE
OR FLUE LINER OF 125MM (5”).
Flue Liner
Fig.11
Note:
Fill voids and area around liner with vermicu-
lite or a comparable approved material. (See Fig. 11
& 12)
CHIMNEY’S
Generally the most effective chimney for oil is one
that is straight, avoid offsets and terminate with a
straight sided pot.
8
Simmer Plate
Pipe Bend
Cleaning Plate
Hotplate
Flex Pipe
Adaptor
Seal Bend to
Connecting Collar
Vermiculite or a
comparable material
125mm (5”)
Flexible Flue Liner
Fire Sealing
Cement
Flue Increaser /
Reducer
Closure
Plate
Flue Diameter
of 150mm (6”)
Cleaning Plate
cooker. Following these, the diameter of the
chimney / flue should be reduced to 5” (125mm).