background image

EX5210R Exciter Installation & Configuration Guide 

 

13

 

LF Coverage 

The EX5210R has an adjustable coverage range between 0.5m (1.6 ft.) and 6.5m 

(21.3 ft.) in intervals of 0.5 m (1.6 ft.). LF Coverage varies according to location*  

*Indoor LF Coverage is around 6.5 meters (21.3 feet). Outdoor LF Coverage is 

around 3 meters (9.8 feet). 

 The LF coverage pattern set at 4m is displayed in Figure 5. 

 

Figure 4: EX5210R LF range and coverage pattern set at 4m 

 

Содержание AeroScout EX5210R

Страница 1: ...EX5210R RUGGED EXCITER INSTALLATION CONFIGURATION GUIDE DRAFT 1 Updated 2018 10 10...

Страница 2: ...ut is a trademark of Stanley Black Decker Inc or its affiliates Other brand products and service names are trademarks or registered trademarks of their respective holders Below is a partial listing of...

Страница 3: ...Behavior Modification 7 Message Programming Functions 8 Network Connectivity 8 Chaining 8 LED Status Indicators 9 Exciter Connector Panel 10 Wiring the Exciter 12 LF Coverage 13 Network and Power Conn...

Страница 4: ...onfiguration Guide 4 Resetting the Exciter IP Address 24 Mounting the Exciter 25 Fixing the Exciter to a Wall Ceiling 25 Mounting the Exciter to a Poll 27 Appendix A Exciter and Accessories 28 Appendi...

Страница 5: ...proach the Exciter Tags in turn transmit a message to either the AeroScout Location Receivers or to compatible Access Points within range The Exciter can activate or deactivate tags program them or ev...

Страница 6: ...a real time view of the production line The type and quantity of products can be tracked through each step in the process Automatic Inventory Management Logistics organizations can update inventory re...

Страница 7: ...indoors the Exciter s LF coverage range can reach up to 6 5meters Note The Exciter s effective range may be less than the configured range due to specific site or environmental conditions The effectiv...

Страница 8: ...created messages Store up to 15 bytes of data sent to it by the Exciter Network Connectivity When connected to the network the Exciter can be remotely programmed monitored and its firmware can be upd...

Страница 9: ...D that changes color based on the Exciter s status as follows Green continuous The Exciter is transmitting and functioning correctly Green Blinking During Firmware upgrade the Exciter blinks green unt...

Страница 10: ...citer Connector Panel The EX5210R Exciter connection panel is housed in the sealed compartment at the back of the Exciter Unscrew the 8 mounting plate screws and remove the plate Exciter Mounting Plat...

Страница 11: ...xciter and can be purchased separately When PoE is used this connector becomes redundant 3 Chain IN RJ 45 connector This connector is used for receiving data from Chained Exciters The Chain IN port is...

Страница 12: ...ubber plug and then connected to the required port Use the cable holder to keep the cables in line with the rubber s holes Once the cables are connected correctly place and screw in the mounting panel...

Страница 13: ...n 0 5m 1 6 ft and 6 5m 21 3 ft in intervals of 0 5 m 1 6 ft LF Coverage varies according to location Indoor LF Coverage is around 6 5 meters 21 3 feet Outdoor LF Coverage is around 3 meters 9 8 feet T...

Страница 14: ...nnected to a network EX5210R can be remotely controlled for configuration and monitoring purposes via the local area network In this case you need to connect it to both a power source and the network...

Страница 15: ...ficient for more Exciters must only be powered by a limited marked LPS or NEC class 2 power supply PoE Switch If your network has a Power over Ethernet infrastructure you can connect a CAT 5 6 Etherne...

Страница 16: ...onnector thus supplying both power and network connectivity When using this injector the Exciter power jack is not used Figure 6 110 220 VAC to 48VDC PoE Single Port Injector The injector s IN connect...

Страница 17: ...Supply Input Output Maximum Current Available Power Maximum of Exciters with One Source PoE single port injector 100 240 VAC 50 60 Hz 48 VDC 0 32 A 1 15 4 W Two Standard PoE 802 3af switch port 2 48...

Страница 18: ...ansmission range overlap between neighboring Exciters This ensures full coverage of the area Figure 8 shows 5 Chained Exciters their connections and the state of each Exciter termination switch Figure...

Страница 19: ...ing Chained Exciters Each Chained Exciter must be set as Slave Exciter and the transmission range configured in the AeroScout Engine Manager before being connected to the Primary The EX5210R appears a...

Страница 20: ...iter Modules General Settings tab make sure Enable is checked Under Chaining and External Connections General Settings tab check Slave Exciter 4 Under IP Configuration uncheck Connected to Network 5 C...

Страница 21: ...configure the following parameters Under General LF Parameters select LF Chaining as Chained 4 Select the Internal LF tab and configure the following Select the desired Transmission Range of the Chain...

Страница 22: ...EX5210R Exciter Installation Configuration Guide 22 6 Click OK 7 Connect the Chained Exciter to the Primary Exciter...

Страница 23: ...n available IP every time the device connects to the network Exciters with firmware version 314 54 and above will be set to DHCP by default The Exciter s IP can be changed via the Location Engine Sele...

Страница 24: ...ou can reset the Exciter s IP address to the factory default value The default IP address is 192 168 1 178 To do so press the IP Reset button with a ballpoint pen for 5 seconds After a successful IP r...

Страница 25: ...ng using a specifically designed mounting plate Mounting options include Walls Ceilings Polls Fixing the Exciter to a Wall Ceiling 1 Using the mounting plate as a template place and hold the mounting...

Страница 26: ...iguration Guide 26 5 Align the Exciter with the attachment hooks on the mounting plate 6 Place the Exciter into the mounting plate and press the Exciter down until it locks into place Exciter attachme...

Страница 27: ...Exciter s side screw holes 8 Screw in the Exciter to the mounting plate s security flanges Mounting the Exciter to a Poll The mounting plate can be mounted to a poll using a U Bolt mounting kit Once t...

Страница 28: ...AC DC Adaptor 45W 48 V 1 0A 90 264VAC for EX2000B EX4210 EX5000 EX5200 and EX5210R Exciters PoE Injector ADP 030 U US ADP 030 E Europe ADP 030 UK UK ADP 030 J Japan PoE Power Injector for use with EX...

Страница 29: ...ers 9 8feet even if it is set to the maximum of 6 5m in the Engine When used indoors the Exciter s LF coverage range can reach up to 6 5meters LF Channel 125 KHz Field intensity limits 66dBuV m 10m ET...

Страница 30: ...een the device and the receiver Connect the device to an outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING...

Страница 31: ...Healthcare s By Your Side Lifetime Customer Care commitment to ensure that every customer achieves success and realizes the full value of their investment through consulting training implementation an...

Отзывы: