background image

 

1/08       N138647 

 
The Ice Merchandiser utilizes a programmable controller to control the temperature and 
defrost settings.  The controller, which is located on the facade of the unit, is factory set. 
Please see the default settings sheet and separate instructions that are included on the 
operation of this controller.  
 
After shutting the door on freezer models, a short amount of time must be allowed before 
the door can be reopened.  This is due to the tight seal maintained between the door and 
the cabinet. Waiting a few moments for the pressure to equalize permits the door to be 
opened easily. 
 
A positive defrost is required to remove frost from the coil in freezer models. This is 
accomplished by energizing heaters during the defrost cycle that are positioned on the coil 
surface.  The programmable controller is factory set to allow four defrosts per day. 

 

 
As the preset defrost time is reached, the controller automatically terminates the 
refrigeration process by turning off the condensing unit and unit cooler fan motors, and 
energizes the defrost heaters.  As the coil temperature increases, the frost begins to melt 
producing water which runs down the coil to the unit cooler drain pan and exits through the 
drain tube to the vaporizer.  After all the frost has been removed and the coil temperature 
reaches approximately 50°F [10ºC], the defrost is terminated through the action of the 
defrost termination control located on the unit cooler, and the refrigeration process 
resumes. 

 

 

 

GENERAL MAINTENANCE  

 

PERIODIC CLEANING 
WARNING! To avoid electrical shock, disconnect all electrical power to the 
merchandiser prior to cleaning

 

 

The exterior of the Ice Merchandiser should be wiped with a damp cloth daily. A 
commercial grade glass cleaner may be used. 

Do not use a brush, scouring pad or any 

other abrasive material on the painted surfaces. 

 
The interior (and exterior if desired) may be cleaned with a soft cloth and a mild germicidal 
detergent. 

Do not use any ammonia-based products  as this may damage electrical 

components within the unit. 

Do not use a brush, scouring pad or any other abrasive 

material on the painted surfaces. Care should be taken not to wet any electrical 
components, connections or controls. 
 
Monthly cleaning of the condenser will aid the heat transfer characteristics of the 
refrigeration system and increase its efficiency.  To accomplish this, remove the bottom 
facade from the cabinet by removing 2 screws located at the bottom of the facade on each 
side. Slide facade down off key slots and pull out to remove. Use a bristle brush to loosen 
any dirt particles that are attached to the fins. Use a vacuum cleaner to remove the 
loosened particles and other debris. If dirt is noticeable on the fan blades, simply wipe the 
blades with a damp cloth. 

Failure to keep the condenser coil clean and clear of 

obstructions could result in temperature loss and damage to the compressor.

 

 
All moving parts have been permanently lubricated and will generally require no 
maintenance.  
 

 