background image

WS150 User Manual

14

8 Troubleshooting

Note: to isolate a problem, the masthead may
be connected to the red connector on the
WS150.

1 No display:
• Check DC power connections and DC polarity

with voltmeter. Voltage must be between 10.7
and 16.6 volts.

2 Faulty wind speed or wind direction
indication:
• 1. Possible defective Masthead Cable

2. Possible defective Masthead Assembly
3. Possible defective instrument

• Remove the Masthead Assembly from the

masthead and connect it directly to the
instrument red moulded cable. If the indication
is normal, the Masthead Cable is defective. If
the problem persists, contact your supplier for
service.
NOTE: The instrument and Masthead
Assembly may be connected directly for
linearization of the repaired or new equipment
prior to installation.

3 Simulation Mode
• At power up, if all the segments display for 5

seconds then the instrument is in simulation
mode.

7 Specifications

Power Supply
• 10.7 to 16.6 VDC, 30mA nominal, 40mA with

backlight on.

Operating temperature
• 32° to 113°F (0° to 45°C)

Size of display
• 4.4 x 4.4 x 1" (112 x 112 x 24mm), overall

depth 1.4" (35mm) behind panel.

Display type
• Twisted Nematic (TN) grey background,

32° to +158°F (0° to +70°C).

Illumination
• Red LED.

RF interference
• Less than 6 dB maximum quieting on any

marine radio channel with 3 dB gain antenna
within 1 meter of instrument display head.

Wind Direction
• Apparent and true 180 degrees to port and

starboard.

Wind speed
• 0 to 99 knots, or 0 to 50 m/sec with maximum

wind speed recording.

4 Masthead cable is not long enough:
• Use the optional HS50 cable. Maximum of two

cables can be connected.

5 Wind speed:

5a Erratic or no wind speed
• Check green wire in junction box or other splice

in masthead cable.

• Check power supply.

5b Tricup seems to spin slower
• Remove head and clean tricup

5c Slow wind speed (Tricup spins freely)
• See wind speed calibration section 4.6.3

6 Wind Direction:

6a Erratic or no wind direction, does not

point in all directions (port/starboard)

• Check white and green wires
• Check power supply.

6b Reacts slow to wind changes
• See Wind Direction Damping section 4.6.4

6c Mast Cable wires and their descriptions
• Shield:

Battery Ground

Red:

+ 12VDC

Green:

Wind Speed

Brown:

Wind Direction

White:

Wind Direction

Alarm
• Wind speed alarm user settable value.

VMG display
• Displayed in 0.1 steps to 19.9 knots and 1.0

steps above 20 knots.

NMEA input (for VMG and True Wind Data
calculation)
• Accepts VHW sentence from SL150 speed log

or other instrument with NMEA output.

NMEA output
• NMEA 0183 format VWT, VWR, MWV, VPW

for RP150 system repeater or other NMEA
compatible instrument. Short circuit protected.
Drive capability for up to four NMEA
receivers.

Transducer cables.
• 5 pin Fuji connector for wind mast head

transducer, 5 conductor cable for NMEA input,
output and power connections.

Transducer
• Lightweight weatherproof type with 30 meters

of cable. Electronic sine cosine output.

Содержание WS150

Страница 1: ...WS150 Wind Speed Point Owner sManual Marine Division of Vertex Standard ...

Страница 2: ... This limited warranty does not extend to any product which has been subjected to misuse neglect accident improper installation or subject to use in violation of the maintenance or operating instructions if any furnished by STANDARD HORIZON nor does this warranty extend to products on which the serial number has been removed defaced or changed STANDARD HORIZON reserves the right to make changes or...

Страница 3: ...tion 9 4 5 2 Masthead Cable Installation 9 4 6 Calibration 11 4 6 1 Linearization of the Wind Sensor and Instrument 11 4 6 2 Wind Direction Calibration 11 4 6 3 Wind Speed Calibration 12 4 6 4 Wind Direction Damping 12 4 7 Microprocessor Reset 12 5 Operation 12 5 1 Backlighting On Off 12 5 2 Wind Speed Alarm On Off 12 5 3 Set Wind Speed Alarm 13 5 4 True or Apparent Wind Display 13 5 5 Select Spee...

Страница 4: ...WS150 User Manual 5 ...

Страница 5: ...0 Dust cover 1 2 Front panel The front panel includes a large LCD and three button keypad The keypad uses both tactile and audible feedback to indicate when a key is pressed All functions are controlled entirely by these three keys The front panel also includes separate icons which indicate that the instrument is displaying either true TRU or apparent APT wind speed wind direction 1 3 Rear panel T...

Страница 6: ... 2 Remove the nut Peel the protective paper off the foam gasket and attach the gasket to the rear of the instrument 3 Insert the instrument through the bulkhead Hand tighten the nut and then finally tighten with a spanner Do not over tighten so that the water sealing ability of the gasket is damaged 3 Accessories 3 1 Replacement Parts The following parts may be ordered from the Standard Horizon Pa...

Страница 7: ...ovide protection for up to five 150 series instruments 3 Connect the 5 pin Fuji connector to the wind transducer cable connector Do not cut or shorten the transducer cable Extension cables are available if the transducer cable is too short 4 If you are not interfacing to a SL150 speed instrument or RP150 repeater or you do not intend to provide NMEA data to another instrument then insulate the bar...

Страница 8: ...model SL150 speed instrument to display true wind speed direction and speed VMG data on the WS150 display The WS150 may also be connected to the RP150 system repeater or to any other instrument that will accept standard NMEA 0183 data The NMEA sentences are VWT VWR MWV and VPW Fuji Plug Socket Wind Transducer Red Black Green Blue 1A Fuse 12 VDC Ground NMEAdatatoWind NMEA speed data SpeedTransducer...

Страница 9: ...ction Box matching the wire colors of the cut cable ends 9 Take the Masthead Assembly up the mast Connect the Masthead Assembly electrical connector to the electrical connector on the mounting block While supporting the weight of the masthead Assembly tighten its threaded support sleeve to the threaded support on the Mounting Block 10 Apply power and perform Calibration procedure see section 4 6 i...

Страница 10: ...tion process rotate the wind vane as many times as necessary for the wind direction indicator to make a complete 360 degree circle without the indicator stopping Press hold for 3 seconds to enter calibration mode Press both keys to step to next function Wind Direction Damping Wind Speed Calibration Wind Direction Calibration Linearization Presskeysto change values or or or or To exit any time or r...

Страница 11: ...he accuracy of the display wind direction repeat the linearization alignment calibration procedures 4 6 4 Wind Direction Damping This setting controls the rate the displayed wind angle changes There are four levels of damping d0 d1 d2 and d3 The most heavily dampened setting is d3 and d0 for no damping The WS150 is factory set for a damping of d2 To change the damping setting perform the following...

Страница 12: ...set Maximum Wind Speed While Maximum Wind Speed is displayed press and hold the and keys for 3 seconds to reset the maximum wind speed to zero Note All calibration settings will be reset to the factory defaults 5 5 Select Speed Function Press the key to switch between Wind Speed Maximum Wind Speed and VMG Your wind speed point instrument is designed for years of trouble free operation assuming pro...

Страница 13: ...ead Wind Direction Apparent and true 180 degrees to port and starboard Wind speed 0 to 99 knots or 0 to 50 m sec with maximum wind speed recording 4 Masthead cable is not long enough Use the optional HS50 cable Maximum of two cables can be connected 5 Wind speed 5a Erratic or no wind speed Check green wire in junction box or other splice in masthead cable Check power supply 5b Tricup seems to spin...

Страница 14: ...17210 Edwards Road Cerrtios CA 90703 Telephone 562 404 2700 STANDARD HORIZON ALL RIGHTS RESERVED PRINTED IN NEW ZEALAND FEBRUARY 2001 EED4100BD 1950753A MN000017 Marine Division of Vertex Standard ...

Отзывы: