3. Troubleshooting
26
(COUNTERMEASURE)
Turn off power, remove jammed sheet
(Refer to "4-3 How to Remove Jammed
Sheets" in page 37.) Then push breaker
button and turn on power.
(COUNTERMEASURE)
Turn off power and turn stopper micro
adjust knob counterclockwise (3 turns).
Then push breaker button. In case stopper
will be locked as soon as power is ON, call
your local dealer.
(COUNTERMEASURE)
Turn off power and turn stopper micro
adjust knob so that stopper moves up about
20 mm. Then push breaker button. When
power is turned on, depress and hold clear
button.
In case Stopper will be locked as soon as
power is on, call your local dealer.
NOTE
If above is performed, memorized folding size in
Memory 1 and Memory 2 will be erased.
3-1 Trouble Message Is Indicated on LCD.
In case of miss operation or improper process of function, trouble message is indicated on
LCD. Follow countermeasure listed below.
INDICATION 1
Error ................. Check Breaker
(CAUSE 1)
Circuit breaker for buckle is tripped
because of paper jam.
(CAUSE 2)
Stopper in 1st or 2nd buckle is
locked at top dead end.
(CAUSE 3)
Stopper in 1st or 2nd buckle is
locked at bottom dead end.
Breaker