background image

COMPUTER TROUBLE SHOOTING GUIDE

22

The Hand Pulse Sensors will NOT operate correctly if your skin is
extremely dry. Moisten your hands with a little water and try again.

Refer to the Assembly Instructions and check all the Wire Plugs are
connected FIRMLY and correctly.

No speed signal

E1

The Computer cannot make contact with the
IC Chip.

Disconnect the Adaptor. Reconnect the Adaptor to REBOOT the system.
Wait two minutes then verify that the system works correctly.

Remove and reinsert the IC Chip. If reinsertion fails, replace the
Computer.

E2

Verify that the correct Adaptor is used.

The LCD Screen
does not display
anything

The Speed
Display shows 0

The LCD Screen
Partially displays

You have the wrong Adaptor.

The Adaptor is not plugged in.

The Computer is faulty.

The Computer isn't receiving a signal from
the Speed Sensor ?

The Sensor is faulty.

The Computer is faulty.

The connection between the Circuit Board
and the LCD Membrane is loose. Gently
press down on the LCD Screen, on the
Computer face, if the partial display
disappears, then it is a connection problem.

The Computer is faulty

the Rubber Membranes between the Circuit
Board and the LCD Screen is misaligned. You
might be able to see that the LCD Screen is
on a slight angle and NOT inline or parallel
with the Computer Case.

Verify that the sensor Magnet is installed correctlly and passes in front of
the Speed Sensor.

Verify that the Circuit Board is securely fastened to the Computer Case.
Retighten the Screws. Take care NOT to over tighten the Screws as this
may destroy the Circuit Board. You just need to keep the Circuit Board
firm, STOP tightening screws when you meet resistance.

The Computer is NOT receiving a Pulse
Signal.

No Hand Pulse
Signal or
incorrect Hand
Pulse Signal

The Computer is receiving a faint or
intermittent Pulse Signal.

The Computer is faulty.

Verify that the Hand Pulse Sensor Wire Plugs are connected FIRMLY
and correctly.

Check Magnetic System and Motor.  The motor should be able to adjust
the resistance of Magnetic System freely.  If the Motor makes abnormal
sounds and struggles to adjust the resistance, try to locate and correct
the problem in the Magnetic System. It may be necessary to replace the
Magnetic System. After correcting the problem, verify that the motor
works correctly.

If an unusually loud noise come from the Motor, it means gears in the
motor gearbox do not mesh correctly. Revere to adjust the resistance,
and try again. If this fails, replace the Motor.

Check that the Adaptor is correctly connected to an electrical outlet and
plugged into the socket on the machine correctly.

Replace the Computer.

Verify the gap between Speed Sensor and the Magnet is 5mm or less.

Verify all theSensor Wire Plugs are connected FIRMLY and correctly.

Verify that the Computer Wires are not damaged.

If all the above checks fail, then replace the Speed Sensor.

Replace the Computer.

Open the Computer Case. Remove the Circuit Board Screws, gently
remove the Circuit Board.  Realign the LCD Screen and the Rubber
Membrane. Reassemble the Circuit Board taking care not to bump or
knock the Rubber Membrane out of alignment before the Circuit Board
Screws are tight. You just need to keep the Circuit Board firm, STOP
tightening screws when you meet resistance.

Replace the Computer.

Grasp the Hand Pulse Sensors firmly and avoid moving your hands while
exercising. The computer will need a few seconds to detect and display
your correct pulse rate. If this does not work, try relaxing your grip on the
Hand Pulse Sensors.

Clean the Hand Pulse Sensors to ensure a good contact between your
body and the Pulse Sensors.

Remove the Hand Pulse Sensors and verify that the spade terminals
are correctly attached.

If the problem still exists, replace the Hand Pulse Sensors.

Replace the Computer.

PROBLEM

POSSIBLE  CAUSE

SOLUTION

Magnetic System gets stuck causing
excessive tension in adjustment cable and
the adjustment motor does not function
normally.

Motor Problems

lf the Motor does not move at all, revere to adjust the resistance, and try
again. If this fails, replace the Motor.

Содержание 55-2065

Страница 1: ...rom equipment when in use Always make sure all bolts and nuts are tightened prior to each use Follow all safety instructions in this manual When calling for parts or service please specify the followi...

Страница 2: ...dizzy or experience pain stop and consult your physician Follow your physician s recommendations in developing your own personal fitness program Consult your physician before using the Body Fat Progr...

Страница 3: ...ieving a happier and healthier lifestyle 3 Should you have any questions please call our Customer Service Department toll free number 1 800 375 7520 Monday Thursday 7 30 A M 5 00 P M Central Time Frid...

Страница 4: ...EPPER provides a convenient and simple method to begin your assault on getting your body in shape and achieving a happier and healthier lifestyle Before reading further please review the drawing below...

Страница 5: ...e the washers the ends of the bolts or screws on the circles to check for the correct diameter Use the small scale to check the length of the bolts and screws NOTICE The length of all bolts and screws...

Страница 6: ...t please call our toll free number for assistance 1 800 375 7520 or e mail us at parts staminaproducts com 6 ASSEMBLY INSTRUCTIONS STEP 1 Attach the FRONT STABILIZER 3 the one with wheels onto the MAI...

Страница 7: ...ed to the left PEDAL RAIL ASSEMBLY Attach the left PEDAL RAIL ASSEMBLY to the left side of the Elliptical unit There is a R decal on the RIGHT PEDAL SUPPORT 50 attached to the right PEDAL RAIL ASSEMBL...

Страница 8: ...he channel on the UPRIGHT 4 must be facing toward the back as shown If necessary loosen the mounting SCREWS M4 x 20mm 76 for the LEFT and RIGHT UPRIGHT COVERS 13 14 to provide additional space for the...

Страница 9: ...ecure with SOCKET HEAD BOLTS M8 x 35mm 68 and NYLOCK NUTS M8 85 Slide the STATIONARY HANDLEBAR SLEEVE 38 down to cover the bolts on the STATIONARY HANDLEBAR 103 STEP 8 Connect the UPPER CONNECTION WIR...

Страница 10: ...BOLTS M6 x 35mm 66 and NYLOCK NUTS M6 83 Slide the HANDLEBAR SLEEVE 37 down to cover the bolts on the RIGHT HANDLEBAR 8 Repeat on the left side STEP 10 Attach the MOUNTING BRACKET 109 onto the UPRIGHT...

Страница 11: ...ITE ELLIPTICAL STEPPER The ELITE ELLIPTICAL STEPPER has a pair of MOVING WHEELS 58 built into the FRONT STABILIZER 3 at the front Grasp the center section of the HANDLEBARS 7 8 and tip the ELITE ELLIP...

Страница 12: ...r mode stand on the foot pedals grasp the handlebars move your highest foot downward and follow the natural path of the machine Start at a load level that is comfortable to familiarize yourself with t...

Страница 13: ...g a program Your ELITE ELLIPTICAL STEPPER utilizes a magnetic braking system to create resistance for your workout You control the amount and pattern of this resistance by means of the advanced comput...

Страница 14: ...ATT from 0 to 999 9 watt Press MODE button to select the display of CAL or WATT NOTE The calorie and watt readouts are an estimate for an average user It should be used only as a comparison between wo...

Страница 15: ...ogram time in advance the computer will use the preset value of 30 minuets to count up and cycle run the program profile In this case you can preset the DISTANCE for the program to count down The comp...

Страница 16: ...lse within the heart rate zone 109 to 119 during your workout The program will monitor your pulse and adjust the workload automatically to keep your pulse within the zone which is plus minus 5 Heart B...

Страница 17: ...es A MANUAL PROGRAM P1 STEP 2 SELECT PROGRAM The Manual Program P1 is always displayed first when you turn on the computer If necessary press buttons to select the Manual Program STEP 1 POWER ON Pedal...

Страница 18: ...note that this is a warning for you to slow down or lower the Level of resistance C BODY FAT PROGRAM P8 STEP 1 POWER ON Pedaling or press any button STEP 2 SELECT PROGRAM Press buttons until the PROGR...

Страница 19: ...e you are and diet and exercise correctly for that type you will make much better progress Body Mass Index is a height weight formula used by health and weight professionals around the world to assess...

Страница 20: ...Pedaling or press any button STEP 2 SELECT PROGRAM Press buttons until the desired program is displayed STEP 3 SET THE PROGRAM TIME OR DISTANCE AND AGE Press the ENTER button the TIME function mode wi...

Страница 21: ...p your ELITE ELLIPTICAL STEPPER clean by wiping with an absorbent cloth after use 1 2 3 4 5 6 7 8 OPERATION DESCRIPTIONS To stop a running program press the START PAUSE button In this mode you can pre...

Страница 22: ...tic System and Motor The motor should be able to adjust the resistance of Magnetic System freely If the Motor makes abnormal sounds and struggles to adjust the resistance try to locate and correct the...

Страница 23: ...maximum heart rate zone Start at the lower intensity and build up to higher intensity as you become more aerobically fit If you feel dizzy or lightheaded you should slow down or stop exercising Targe...

Страница 24: ...our cool down should include the stretches listed above and should be completed after each strength training session Lower Body Stretch Place feet shoulder width apart and lean forward Keep this posit...

Страница 25: ...s limited warranty is not transferable IF ANY PART OF THE PRODUCT IS NOT IN COMPLIANCE WITH THIS LIMITED WARRANTY OR ANY IMPLIED WARRANTY THE REMEDY OF REPAIR OR REPLACEMENT IS THE EXCLUSIVE REMEDY AV...

Страница 26: ...26 PRODUCT PARTS DRAWING FRONT BACK...

Страница 27: ...0mm 4 27 Magnet 1 28 Hollow Cap 2 29 Sensor Wire 1 30 Lower Connection Wire 1 31 Upper Connection Wire 1 32 Computer 1 33 Pulse Wire 1 34 Pulse Sensor Wire 2 35 Pulse Sensor Plate 4 36 Foam Grip 2 37...

Страница 28: ...lock Nut M6 x 1 6 84 Thin Nylock Nut M8 x 1 25 x 6mm thick 16 85 Nylock Nut M8 x 1 25 x 8mm thick 10 86 Nylock Nut M10 x 1 25 2 87 Flange Nut M10 x 1 25 2 88 Lock Washer M8 12 89 Washer M8 2 90 Washer...

Страница 29: ...29 NOTES...

Страница 30: ...defective part found please call us from 7 30 A M to 5 00 P M Central Time Monday through Thursday and 8 00 A M to 3 00 P M on Friday or fill out the fax sheet ordering form below and fax it to 417 88...

Отзывы: