USER NOTICE   

1. Safety Precaution 

1. 

Carefully open the box, avoid the accessories, like lens, dropping to ground and being 

damaged.

 

2.

 

Check the input voltage, be sure the input voltage which signed on the microscope is 

consistent with the power supply voltage, or it will bring a serious damage to the instrument. 

3.

 

Do keep the instrument out of direct sunlight, high temperature or humidity, dusty and easy 

shaking environment. Make sure the stage is smooth, horizontal and firm enough. 

4.

 

To prevent the microscope body from turning over, its pivot angle must be limited to 30

°

.  

5.

 

.A microscope is a precision instrument. Handle it with care and avoid subjecting it to sudden 

or severe impact.   

6.

 

Make sure the instrument is earthed, to avoid lighting strike. 

7.

 

Do not disassemble any part of the microscope, especially the electrical parts on the bottom 

side as this may result in electric shock. 

8.

 

Use the factory supplied power cord, please. 

2. Maintenance and Storage 

1.

 

All the lenses have been well checked and adjusted. It is forbidden to disassemble them 

yourself. 

2.

 

The binocular viewing head and focusing unit have a compact and precise frame; please 

don’t disassemble them as possibly as you can. 

3.

 

Keep the instrument clean, wipe dust regularly, and be attention to avoid contaminating the 

optical elements especially.   

4.

 

The contaminations on the prism, as fingerprint and oil, could be gently wiped with a piece 

of soft cloth or tissue paper, gauze which has been immersed in pure alcohol or ether. 

(

Note that the alcohol and ether are highly flammable, do keep them away from the 

fire or potential sources of electrical sparks, and use them in a drafty room as possible 

as you can.) 

5.

 

Do not attempt to use organic solvents to clean the microscope components other than the 

glass components. To clean them, use a lint-free, soft cloth slightly moistened with a 

diluted neutral detergent.   

6.

 

If the microscope is splashed by liquid during using, cut off the power at once, and wipe up 

Содержание STM-3020 Series

Страница 1: ...0B T BD To insure safety and obtain optimum performance and familiarize yourself fully with the use of this microscope We recommend that you read the manual thoroughly before operating the microscope...

Страница 2: ...Components 4 2 Assembly 5 2 1 Assembly Diagram 5 2 2 Detailed Assembly Procedure 6 3 Adjustment and Operation 8 3 1 Adjusting Binocular Viewing Head 8 3 2 Focus Adjustment 9 4 Specification 10 5 Troub...

Страница 3: ...k 8 Use the factory supplied power cord please 2 Maintenance and Storage 1 All the lenses have been well checked and adjusted It is forbidden to disassemble them yourself 2 The binocular viewing head...

Страница 4: ...isassemble any parts of the microscope which will affect the function or decline the performance of the microscope 8 Place the instrument in a cool dry position When not using the microscope keep it c...

Страница 5: ...4 Binocular head and zoom body 1 Components Stereo Microscope STM 3020 WF10 eyepieces Diopter ring Clamping knob Standard base Glass stage stand Focusing knob Power cord Brightness adjusting knob...

Страница 6: ...arious modules The numbers indicate the order of assembly When assembling the microscope make sure that all parts are free of dust and dirt and avoid scratching any parts or touching glass surfaces Bi...

Страница 7: ...e dust caps and gently insert two adjustable eyepieces into the eyepiece sleeves until they stops as in Fig 3 P2 P 1 Note Working Environment Requirement 1 Ambient temperature 5 C to 40 C 41 F to 104...

Страница 8: ...lar head is optional if video or photography function is needed 2 2 4 Video Photography accessories assembly 1 Installing the video set Remove the dust cap of the trinocular viewing tube revolve the c...

Страница 9: ...2 Place an easy to observe specimen on the stage plate 3 Rotate the zoom body knob to the highest magnification 4 5 and turn the focusing knob to focus the specimen 4 Rotate the zoom body knob to the...

Страница 10: ...ging the magnification 1 The zooming knots located at two sides of the zooming body could change the magnification of the specimen image 2 Total Magnification Magnification of zoom body magnification...

Страница 11: ...15 67 5 16 3 56 2 30 20 90 10 2 2 30 135 8 1 78 40 180 6 1 33 5 Troubleshooting Under certain conditions performance of this unit may be adversely affected by factors other than defects If a problem o...

Страница 12: ...ut of focus during observation Tension adjustment ring is too loose Tighten it properly 9 7 Outfit Components Specification Quantity Standard Outfit Main body Main body 1 Standard Observation system B...

Отзывы: