- 13 -
EN
3.
put the plate back on
1
2
1.
Stop rod,
2.
Hole.
7.3.
Adjusting the spring tension
1.
Remove the metal plate from the feeder,
2.
adjust the tension of the springs by removing or placing additional ones on the handle located on the guide tube. To remo-
ve the spring from the feeder, pull it out of the holes located on the rim and on the metal plate guide,
3.
put the metal plate back on.
1
2
1.
Rim,
2.
Hole on the rim,
3.
Spring,
4.
Guide tube,
5.
Plate guide,
6.
Hole on plate guiding member.
7.4.
Notes
There are 3 sets of springs in the feeder chamber. When adjusting, make sure that the same number of springs are installed in
each set.
The springs should, if possible, be evenly distributed on the plate guide. Avoid a situation where the springs are only mounted
on one side of the guide plate.
8. MAINTENANCE
Disconnect the unit from the power source before performing any maintenance.
Daily maintenance consists of cleaning the hood with a cloth dampened in water and dishwashing liquid and then wiping it with
a dry cloth.
At least once a week the grease traps should be washed and the condition of the condensate in the drain plug should be checked.