- 19 -
EN
The device contains R290 or R600a coolant - natural, ecological, flammable gas.
Take special care when transporting and installing the device to avoid dama-
ging the cooling circuit.
If a leak is revealed, refrain from using devices/items that could cause sparks
or fire and ventilate the room. To avoid the formation of a flammable gas
mixture in the event of a leak from the refrigeration system, install the device
in a room with area of 1m
3
per every 8 g of the coolant. The amount of coolant
is given in „TECHNICAL DATA/PRODUCT CARD” and on the nameplate.
4. PRODUCT CARD
Model
8410
6
1
8410
6
2
Intended use
storage
storage
Operating temperature
cooling
cooling
Category
counter chilled
counter chilled
Refrigerants:
R600a, GWP=3
R600a, GWP=3
Parameter
Value
Annual energy consumption AEC (kWh)
1121
11
92
Coefficient of energetic efficiency EEI
4
8.7
46.
3
Net capacity V
N
(L)
201
307
(where applicable)
Refrigeration capacity V
NRef
(L)
201
307
Freezing capacity V
NFrz
(L)
0
0
Amount of refrigerant (kg)
0.09
5
0.09
5
5. TRANSPORT AND STORAGE
The appliance is protected with a protective film, placed on a wooden pallet, packed in a cardboard box
and secured with stripes.
•
packaged appliance should be stored in a covered warehouse at an ambient temperature of 0 °C / + 55
°C and humidity of 30 - 95 %;
•
it is forbidden to stack appliances;
•
read the data on the appliance rating plate. In case of damage or loss of the rating plate it should be
replaced immediately;
•
do not unscrew the safety guards;
•
after unpacking the appliance, carefully remove the protective film and other elements protecting the
appliance during transport;
•
while lifting the appliance with a lift, position the lift on the outside of the frame;
•
transport the appliance and store it exclusively in a vertical position. Never place the appliance on its
side or upside down, because it can damage the cooling system (not subject to warranty repair);
•
after transporting or moving the appliance wait 2 hours before starting it;
•
do not place the appliance in the vicinity of flammable products, outdoors or in a place subject to direct
sunlight exposure.
6. CONTROL PANEL