S E R V I C E H O T L I N E : 8 0 0 . 7 2 7 . 8 5 2 0 H O T R O N I X . C O M
The Craft Press
Connecting the System
CONNECT THE POWER CORD
Connect the power cord into a properly grounded electrical outlet with a sufficient
amperage rating.
VOLTAGE:
120 Volt - The Craft Press Digital Clam requires a full 20 amp grounded circuit for 120 volt operation.
220 Volt - The Craft Press Digital Clam requires a full 10 amp grounded circuit for 220 volt operation.
EXTENSION CORDS:
If used, should be as short as possible and not less than 12 gauge.
Heavy duty cords are recommended.
CIRCUITS:
that have less than 15 amps or that have other high demand equipment or heat presses
plugged in should not be used.
NOTE:
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly
qualified person in order to avoid hazard. Use SJT type rated 300 V cord for replacement.
CAUTION:
Failure to follow these instructions will cause:
1.
Erratic controller functions.
2.
Inaccurate displays and slow heat-up.
3.
The circuit breaker to disengage.
The Craft Press DIGITAL CLAM
The Craft Press Digital Clam Operating Instructions are designed with the user in mind. Carefully read and follow the step-
by-step instructions for best results.
To avoid burns, do not touch the heated platen
during use.
Keep hands clear of the upper platen of the press
during platen lock down as the pressure may
cause injury.
Press should be placed on a sturdy, suitable stand
at least 36”L x 24”W x 29”H.
Work area must be kept clean, tidy and free of
obstructions.
1.
PAGE 6
Operating Instructions
1.1