background image

Transport and storage

8

252160 / YL460300010

2016-02-12·BA00·III·en·00

Intrinsically Safe Combination Signal - 

100 dB (A) / LED Beacon

Series YL4IS

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

For further technical data, see www.stahl-ex.com.

6

Transport and storage

• Transport and store the device only in the original packaging.

• Store the device in a dry place (no condensation) and vibration-free.

• Do not drop the device.

7

Mounting and installation

The device is approved for use in gas explosion hazardous areas of Zones 1 and 2  

and dust explosion hazardous area of Zones 21 and 22 and in safe areas.

Mechanical data

Cable entries

1 x M20

Material

Enclosure

ABS, flame retardant

Lens

polycarbonate, flame retardant

Assembly parts

stainless steel fixings

Labels

polyester foil, adhesive

Degree of protection IP55 acc. to IEC 60529

Mounting / Installation

Mounting

Should be mounted to a reasonably flat wall or bulkhead of suitable material 

using the lugs projecting from the side of the enclosure. The minimum  

recommended length of fixing screws is 25 mm. To maintain the integrity  

of the weather seal the cable entry must be fitted using a suitable sealed gland.

Connection

Independent wiring or combined supply

2.5 mm

2

 terminals

DANGER

Explosion hazard due to installation without approved field enclosure!

Non-compliance results in severe or fatal injuries!

• When used in Zone 1, the device must be installed into an enclosure  

that complies with the requirements of IEC/EN 60079-11.

• When used in Zone 2, the device must be installed into an enclosure  

that complies with the requirements of IEC/EN 60079-15.

• When used in Zones 21 and 22, the device must be installed into  

an enclosure that complies with the requirements of IEC/EN 60079-31.

Technical Data

Содержание YL4IS Series

Страница 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www stahl ex com EN Intrinsically Safe Combination Signal 100 dB A LED Beacon Series Y...

Страница 2: ...operating instructions 3 2 2 Warning notes 4 2 3 Symbols on the device 4 3 Safety notes 5 3 1 Operating instructions storage 5 3 2 Safe use 5 3 3 Modifications and alterations 5 4 Function and device...

Страница 3: ...w stahl ex com 1 4 Conformity with standards and regulations See certificates and EC Declaration of Conformity www stahl ex com The device has IECEx approval See IECEx homepage http iecex iec ch 2 Exp...

Страница 4: ...the instruction results in severe or fatal injuries to persons WARNING Danger to persons Non compliance with the instruction can result in severe or fatal injuries to persons CAUTION Danger to person...

Страница 5: ...the device is not damaged Work on the device installation maintenance overhaul repair may only be carried out by appropriately authorized and trained personnel During installation and operation observ...

Страница 6: ...on hazard due to improper use Non compliance results in severe or fatal injuries Use the device only in accordance with the operating conditions described in these operating instructions Use the devic...

Страница 7: ...ment T4 Models only Sound stages 2 Sound selection via DIL switch Luminous characteristics Light source 8 array LED Flash rate 1 s Lens colour amber red green opal blue clear Ambient conditions Operat...

Страница 8: ...lyester foil adhesive Degree of protection IP55 acc to IEC 60529 Mounting Installation Mounting Should be mounted to a reasonably flat wall or bulkhead of suitable material using the lugs projecting f...

Страница 9: ...on strictly according to the instructions and national safety and accident prevention regulations to maintain the explosion protection Select and install the electrical device so that explosion protec...

Страница 10: ...N EN EN EN EN EN 7 1 Dimensions fastening dimensions Dimensional Drawings All Dimensions in mm inches Subject to Alterations 14000E00 16547E00 91 50 3 60 91 50 3 60 81 50 3 21 2 x M20 A 1 x M20 A 2 x...

Страница 11: ...ally Safe Combination Signal 100 dB A LED Beacon Series YL4IS 7 2 Mounting dismounting operating position 7 2 1 Assembly 17771E00 Open the device Drill holes for mounting the back of the enclosure to...

Страница 12: ...7 3 1 Key components Exploded diagram for the model used with YL4 6 001 001 0 YL4IS D5 Prewiring The sound pressure transducer F is fixed to the back side of the sounder front cover 4 It is prewired...

Страница 13: ...ording to the circuit diagram Supply the active device with power The device contains two printed circuit boards The PCBs can be wired independently or can be connected together by looping in and out...

Страница 14: ...red Wires C and D not included in delivery Two stage alarm Tone selection of the sound stages 17777E00 A 0v B v C 0v D v The device has a first and second sound stage First sound stage Users can selec...

Страница 15: ...ith power according to the circuit diagram for the second tone frequency A dual channel barrier or double intrinsically safe connection is required Tone switching using reverse polarity Connect the le...

Страница 16: ...line monitoring is required this can be achieved by using an end of line resistor For this purpose use a wire wound or metal layer resistor with a resistance value of at least 750 Ohm and a rated powe...

Страница 17: ...0 4 0 1 14 1 1 0 1 1 98 24 6 Two alternating tones 430 470 1 0 14 0 1 0 1 1 98 24 7 Two alternating tones 800 1000 0 13 12 1 0 0 1 1 100 25 8 Two alternating tones 2500 3200 0 07 13 0 0 0 1 1 102 34 9...

Страница 18: ...rrupted tone 700 0 25 10 1 0 0 1 0 97 23 24 Interrupted tone 720 0 7 0 3 10 0 0 0 1 0 99 24 25 Interrupted fast rising volume 1400 0 25 26 1 1 1 0 0 101 28 26 Fast siren 250 1200 0 085 11 0 1 1 0 0 99...

Страница 19: ...ure that the plug pin surface is not damaged Use only in completely mounted state 9 Maintenance and repair 9 1 Maintenance 9 2 Repair DANGER Explosion hazard due to incorrect installation Non complian...

Страница 20: ...es located in potentially explosive areas may only be cleaned using a damp cloth When cleaning with a damp cloth use water or mild non abrasive non scratching cleaning agents Do not use aggressive det...

Страница 21: ......

Отзывы: