Accessories and Spare parts

14

205582 / 8581615300

2014-10-10·BA00·III·en·03

SolConeX Switch Socket, 125 A 
8581/31

13 Accessories and Spare parts 

 WARNING

Use only original R. STAHL accessories and spare parts.

Designation

Figure

Description

Art. no.

Weight

kg

Switch insert

8549/1-31L Load and motor switch

168776

4.720

Plastic cable gland

02055E00

239157

0.020

8161/

7

-M63-48

28

239161

0.120

Stopping plug

04840E00

143524

0.007

8290/3-M63 x 1,5

143548

0.030

Auxiliary contact, 

series 8080/1

12446E00

2 NC contacts (8080/1-3) 

2)

168356

0.026

1 NC c 1 NO contact (8080/1-1) 

1)

168351

0.026

2 NO contacts (8080/1-4) 

2)

168353

0.026

The switching function of the auxiliary contact depends 

on the installation slot used.

1)

 left: delayed (ON), advanced (OFF); 

right: synchronising

2)

 left and right: synchronising

Ex i cover

12451E00

Ex i cover for auxiliary contacts for use in Ex i circuits

168855

0.008

Auxiliary contact key

14151E00

for removing the mounted auxiliary contact

201909

0.035

Assembly kit  

Cable lugs

14502E00

for the connection of conductors with cable lugs

211465

0.327

8161/7-M25-1707

50 pieces

8290/3-M25 x 1,5

1 pieces

Содержание SolConeX8581/31

Страница 1: ...Operating instructions SolConeX Switch Socket 125 A 8581 31...

Страница 2: ...2 Installation Conditions 9 7 3 Opening Closing the Enclosure 11 7 4 Mounting and Operating Position 11 7 5 Electrical Connection 11 7 6 Connection 12 8 Auxiliary Contacts 12 8 1 Mounting Auxiliary Co...

Страница 3: ...installation place For correct operation please observe all other operating instructions enclosed in this delivery and the operating instructions of the equipment to be connected Safety Instructions N...

Страница 4: ...lates fixed directly to the device 3 2 Modifications and alterations 3 3 Special Versions For special versions the actual components included in delivery may differ from the de scription given here in...

Страница 5: ...auxiliary contacts for Ex i circuits E II 2 D Ex tD A21 ib IP66 T65 C Ta 30 40 C E II 2 D Ex tD A21 ib IP66 T75 C Ta 30 45 C Certificates IECEx IECEx PTB 06 0034 Europe ATEX PTB 01 ATEX 1161 Ambient...

Страница 6: ...5 x 1 5 1 x M63 x 1 5 Enclosure material polyester glass fibre reinforced Degree of protection IP66 acc to IEC EN 60529 Auxiliary contacts Standard version 8080 1 1 1 NC contact 1 NO contact in left i...

Страница 7: ...The devices must be stored in a dry place and vibration free 06556E00 06555E00 3 P PE 8581 31 4 3P N PE 8581 31 5 No of poles Frequency Rated operational voltage Colour code Earth contact sleeve posit...

Страница 8: ...f electric shock Before opening the device disconnect it from the power supply WARNING Use approved components only For unused enclosure holes use R STAHL stopping plugs for unused cable entries use R...

Страница 9: ...able washers all screws and nuts have been firmly tightened 7 5 Electrical Connection The information given in chapter Technical Data must be observed The conductor connection must be made with partic...

Страница 10: ...d 1 NO contact in the left installation slot A maximum of 2 Type 8080 1 auxiliary contacts can be used The switching function of the auxiliary contact depends on the installation slot used see chapter...

Страница 11: ...enclosed circuit diagram indicating the respective switching function to the rating plate of the switch 8 2 Dismounting Auxiliary Contacts Introduce the auxiliary contact key art no 201909 with the St...

Страница 12: ...e that no components are damaged the device has been installed according to regulations there are no foreign bodies inside the device all screws and nuts have been firmly tightened the prescribed tigh...

Страница 13: ...hort circuit in the Main Circuit 11 Cleaning The device may only be cleaned with a damp cloth 12 Disposal Observe the national waste disposal regulations NOTICE Switching on and off has to be done swi...

Страница 14: ...iary contact series 8080 1 12446E00 2 NC contacts 8080 1 3 2 168356 0 026 1 NC contact 1 NO contact 8080 1 1 1 168351 0 026 2 NO contacts 8080 1 4 2 168353 0 026 The switching function of the auxiliar...

Отзывы: