SolConeX extra-low voltage coupling
Series 8573/14
10
Maintenance, Overhaul, Repair
10.1 Maintenance
• Consult the relevant national regulations to determine the type and extent of
inspections.
• Adapt inspection intervals to the operating conditions.
At a minimum, check the following points during maintenance work on the device:
• Firm fit of the conductors,
• Damage on the enclosure, seals or surface,
• Dirt on the sleeves,
• Compliance with the permissible temperatures (according to IEC/EN 60079),
• Whether the device is used in accordance with its intended use.
10.2 Overhaul
10.3 Repair
DANGER
Overheating and explosion hazard due to defective switching contacts!
Non-compliance results in severe or fatal injuries.
• Replace the entire socket flange after each short circuit in the main
circuit of the switch because the state of the switching contacts
cannot be checked in hermetically sealed equipment.
Observe the relevant national regulations in the country of use.
DANGER
Explosion hazard due to improper repair!
Non-compliance results in severe or fatal injuries.
• Repair work on the devices must be performed only by
R. STAHL Schaltgeräte GmbH.
DANGER
Explosion hazard due to improper repair!
Non-compliance results in severe or fatal injuries.
• Hermetically sealed connections are to be repaired only in
conformity with the manufacturer's description.
• Repairs are permitted based on the values in Table 2 or 3 of
standard IEC 60070-1: 2014.