Technical Data
8
243207 / 857360300030
2018-01-16·BA00·III·en·01
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
SolConeX extra-low voltage coupling
Series 8573/14
Technical Data
Electrical data
Rated operational
voltage
max. 50 V
Frequency
0 to 60 Hz (for frequencies > 100 Hz reduction to 12 A required)
Voltage tolerance
-10 to +10 %
Utilization category
AC-3: 50 V / 16 A
DC-1: 50 V / 16 A
DC-13: 50 V / 16 A
Rated insulation
voltage
275 V
Back-up fuse
without thermal
protection
16 A gG
with thermal
protection
35 A gG
Ambient conditions
Ambient temperature -50 to +60 °C,
-40 to +60 °C, optional (silicone-free)
The maximum rated operational current depends on the conductor
cross-section and the ambient temperature.
Mechanical data
Number of poles
2P / 3P
Enclosure material
Polyamide, glass fibre reinforced
Degree of protection IP66 acc. to IEC/EN 60529
Connection type
Screw terminals
Connection
cross-section
Ambient
temperature
Ta
(
+45 °C
Ta
(
+55 °C
Ta
(
+60 °C
Conductor
cross-section
Rated operational current
4 mm
2
16 A
12 A
10 A
2.5 mm
2
16 A
12 A
10 A
1.5 mm
2
10 A
7 A
6 A
1 mm
2
8 A
6 A
5 A
0.75 mm
2
6 A
4 A
3 A
finely stranded
1 x 0.75 mm
2
to 1 x 4 mm
2
finely stranded with
core
end sleeve
1 x 0.75 mm
2
to 1 x 4 mm
2