Junction Boxes
Series 8102
5
Technical Data
Explosion Protection
Global (IECEx)
Gas and dust
IECEx PTB 15.0010
Ex eb ia/ib IIC T6, T5 Gb
Ex tb IIIC T80°C, T90°C Db
Europe (ATEX)
Gas and dust
PTB 01 ATEX 1136
E
II 2 G Ex eb ia/ib IIC T6, T5 Gb
E
II 2 D Ex tb IIIC T80°C, T90°C Db
Certifications and certificates
Certificates
IECEx, ATEX, EAC (TR)
Technical Data
Electrical data
Rated operational
voltage
690 V
Rated operational
current
max. 25 A
Ambient conditions
Ambient temperature Ex e version with semi glands:
-50 to +55 °C T6/T80 °C; -50 to +70 °C T5/T90 °C
Ex i version with semi glands:
-50 to +70 °C T6
Ex e version with cable glands:
-40 to +40 °C T6/T80 °C; -40 to +70 °C T5/T90 °C
Ex i version with cable glands:
-40 to +70 °C T6
Maximum current load (rated value) dependent on conductor cross-section
and ambient temperature.
Information about temperature class T6 (T5).
At T5: Conductors must be suitable for a temperature range of up to +90 °C.
Minimum
conductor
cross-section
Ambient
temperature
-50 to +40 °C
Ambient
temperature
-50 to +50 °C
Ambient
temperature
-50 to +60 °C
Ambient
temperature
-50 to +70 °C
0.75 mm
2
max. 10 A
max. 10 A
max. 6 A
max. 6 A
1.0 mm
2
max. 12 A
max. 12 A
max. 10 A
max. 6 A
1.5 mm
2
max. 16 A
max. 12 A
max. 10 A
max. 6 A
2.5 mm
2
max. 16 A
max. 25 A
(T5)
max. 16 A
max. 16 A
max. 10 A
max. 16 A
(T5)
4.0 mm
2
max. 25 A
max. 25 A
max. 16 A,
max. 25 A
(T5)
max. 16 A