250341 / 6521615300
2015-12-04·BA00·III·de·00
Maintenance and repair
19
Floodlight
Series 6521/4
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
10.1.1 Cleaning
• Clean the device only with a cloth, brush, vacuum cleaner or similar items.
• When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching
cleaning agents.
• Do not use aggressive detergents or solvents.
10.1.2 Restricted breathing test
The luminaire is equipped with a test device for restricted breathing.
Restricted breathing must be checked after installation and during regular maintenance
acc. to IEC/EN 60079-15.
Inspection according to IEC/EN 60079-15, para. 23.2.3.2.1.1
In order to test restricted breathing (pressure test), the luminaire is equipped with a cable
entry with red stopping plugs.
• Remove the red stopping plug.
• Insert the hose of the test device into the cable entry for testing restricted breathing.
• Hand-tighten the cable entry.
• Use the hand pump to create a vacuum of 0.3 kPa (3 mbar).
The test has been passed if after 90 seconds a vacuum of at least 0.15 kPa (1.5 mbar)
is still present in the luminaire.
DANGER
Explosion hazard due to electrostatic discharge!
Accidents or fatal injury are almost certain to happen!
• Clean the device with a damp cloth only.
17218E00
• Opening for restricted breathing test
Recommendation
Check the luminaire by using the handheld testing instrument for restricted
breathing from R. Stahl Schaltgeräte GmbH (see data sheet).
The test should only be carried out at constant temperature conditions.