FUNCTIONING MODES 

 

 

The unit may control various functions  based on the combinations of the 
Dip Switches: 

 
 

DIP FUNCTION 

ON 

OFF 

SW – 1 

ELECTRONIC FRICTION   The motors  M1 and M2 supply the 

maximum thrust.  

The motors  M1 and M2 
supply the minimum thrust.  

SW – 2 

AUTOMATIC CLOSING  The automatic operation is 

activated 

The semi-automatic 
operation is activated 

SW – 3 

COMMAND 
OPEN/CLOSE 

impulse opens – impulse blocks – 
impulse closes  

impulse opens – impulse 
closes  

SW – 4 

PHOTOCELL SETTING 

the activation of photocells causes, 
during the opening of the gate, its 

immediate stop and during the 

closure of the gate, its immediate 
stop and reopen. 

 

The photocells are disabled 
during the opening phase, 

stops and opens the gate 

during the closing and 
during the interval.  

 

SW – 5 

BATTERING RAM 

The M1 shutter is closed for a 

second to free the electric lock and 
then the opening  restarts.  

The opening phase is not 

provided for the use of the 
battering ram. 

SW – 6 

SHUTTER DELAY 

The M2 delay is 8 Sec. 

The M2 delay is 4 Sec. 

SW – 7 

FUNCTIONING  ½  
MOTORS 

Activated two – motors operation 
mode.  

Activated one– motor 
operation mode.  

SW - 8 

AUTOMATIC LEARNING 

Proceeds the operation of 
automatic learning of the shutter 

movements  and bringing to 

automation the closing time.  

The automatic learning 
phase is deactivated.  

 

 

PROGRAMMING 

 
The programming of the central unit requires the following steps:  
 

 

Manual opening of the gate.   

 

Program  SW – 8 = ON, the blinking unit will emit a steady light

 

to inform the user that the  

programming procedure has been started.  

 

Press the Open/Close button or the radio control button once; the M2 shutter will close 
completely, followed, after 2 seconds, by the other one(M1).  If the shutters are activated 

in the opening phase, power supply  should be cut off and invert the connections in the 
motors in order to enable proper programming.   

 

After closing the two shutters, starts the opening phase(automatically), first activating the 
M1 shutter and then the M2 one until reaching the mechanical positive stops in the 

opening phase (the process of reaching the end points proceeds in slow motion).  

 

From the moment when the shutters have reached the mechanical stops in the opening 
phase, the counting of automatic closing time starts; when the requested time has 
passed, one should press once again the Open/ Close button or the radio control button, 
in order to control the closing of the gate. 

 

 

When the closing operation has come to an end, program SW – 8 = OFF; 

 

End of programming. 

  

Содержание HERMES

Страница 1: ...Instructions 1 Control board for electromechanical gearmotors HERMES ...

Страница 2: ...ce make sure that the power supply has been cut off The feeding cable can be connected only with feeders supplied with proper electric protection In particular make sure that the distance between the contacts is of at least 3 5 mm in order to avoid omnipolar disconnection from the grid Take into consideration the safety devices to be installed and the place where they should be positioned Always h...

Страница 3: ... of gates with 1 or 2 shutters the movement is controlled by the encoder and there is no need to use limit switches 1 VAC 2 VAC 3 5 24 24 4 CONNETTORE MOLEX 6 APM1 10 ELS 11 COM1 12 LAMP 7 CHM1 8 APM2 9 CHM2 13 ENC1 20 FTO 21 STOP 22 COM 14 ENC2 19 APCH F2 10A 250V F1 0 63A 250V DL3 DL2 SW OFF 1 2 3 4 5 6 7 8 23 24 GND SIG M1 M2 J I H G F E D C B A RST ON CN1 15 ENC1 16 ENC1 17 18 ENC2 ENC2 DL1 CO...

Страница 4: ...l 21 Electric contact normally closed by the Stop button 22 Common 23 Input antenna braided wire 24 Input antenna signal Connections radio card CONNECTOR MOLEX A Input antenna signal B Input antenna braided wire C Power supply receiver 12V dc negative pole D Power supply receiver 12V positive pole E Disconnected F Disconnected G Input receiver channel parallel to input of Open Close H Input receiv...

Страница 5: ... obstruction during closing DL3 RED a Led which signals blockade of the gate the LED automatically switches off when the command Stop is activated RST Indicates a couple of Pin that short circuited for example by means of screwdriver allows RESET of the control box INPUTS OUTPUTS DEFINITIONS Input power supply from transformer 20V 10 Motors outputs 24V 100W the motor connected to the terminals 6 7...

Страница 6: ...roceeds the operation of automatic learning of the shutter movements and bringing to automation the closing time The automatic learning phase is deactivated PROGRAMMING The programming of the central unit requires the following steps Manual opening of the gate Program SW 8 ON the blinking unit will emit a steady light to inform the user that the programming procedure has been started Press the Ope...

Страница 7: ...f the semi automatic functioning is activated with SW 3 ON every Open Close command will cause the inversion of gate leaf movement both during the opening and closing phase 4 The Open Close command after the power supply is cut or reset by touching the two Pins marked as RST with the screwdriver point provokes first the complete opening of the gate and then the automatic closing up to the proper m...

Страница 8: ...Instructions 8 Rev 0 03 06 Stagnoli s r l Via Mantova Traversa 1 105 A B 25017 Lonato Bs Italia Tel 39 030 9139511 Fax 39 030 91380 www stagnoli com ...

Отзывы: