Stagnoli HERMES Скачать руководство пользователя страница 2

 Instructions

 

 

2

 

 Attention ! 

 

 

The present user manual is designed for personnel skilled in installation, not for the 

final user; the electrician is then due to inform the user about modes of use of the 

device,  possible danger and about the necessity to apply periodical 

maintenance. 

 

The installation can be carried out only by skilled personnel and in compliance 

with the rules currently in force regarding the automated locks. In particular, the 
installation requires the following of the regulations 89/392 and norm EN 12453 and 

EN 12445..  

 

Use only original parts. Stagnoli do not take any responsibility for damage caused 

by using unoriginal parts.  

 

Before operating the device, make sure that the power supply has been cut off.  

 

The feeding cable can be connected  only with feeders supplied with proper 
electric protection.  In particular, make sure that the distance between the 

contacts is of at least 3.5 mm in order to avoid omnipolar disconnection from the 

grid

 

 

Take into consideration the safety devices to be installed and the place where 

they should be positioned. Always have an emergency stop device available to 
allow proper detachment of the feeding cable.  

 

Do not operate the machine with wet or damp  hands or feet and avoid exposing 

the machine to atmospheric conditions.  

 

The device should be used only according to the purpose that it has been 

designed for, any other use is to be considered as improper and therefore 

dangerous.  

 

Maintenance, including possible replacement of courtesy light unit , can be 

carried out only by skilled staff. 

 

 

 

 
 

Содержание HERMES

Страница 1: ...Instructions 1 Control board for electromechanical gearmotors HERMES ...

Страница 2: ...ce make sure that the power supply has been cut off The feeding cable can be connected only with feeders supplied with proper electric protection In particular make sure that the distance between the contacts is of at least 3 5 mm in order to avoid omnipolar disconnection from the grid Take into consideration the safety devices to be installed and the place where they should be positioned Always h...

Страница 3: ... of gates with 1 or 2 shutters the movement is controlled by the encoder and there is no need to use limit switches 1 VAC 2 VAC 3 5 24 24 4 CONNETTORE MOLEX 6 APM1 10 ELS 11 COM1 12 LAMP 7 CHM1 8 APM2 9 CHM2 13 ENC1 20 FTO 21 STOP 22 COM 14 ENC2 19 APCH F2 10A 250V F1 0 63A 250V DL3 DL2 SW OFF 1 2 3 4 5 6 7 8 23 24 GND SIG M1 M2 J I H G F E D C B A RST ON CN1 15 ENC1 16 ENC1 17 18 ENC2 ENC2 DL1 CO...

Страница 4: ...l 21 Electric contact normally closed by the Stop button 22 Common 23 Input antenna braided wire 24 Input antenna signal Connections radio card CONNECTOR MOLEX A Input antenna signal B Input antenna braided wire C Power supply receiver 12V dc negative pole D Power supply receiver 12V positive pole E Disconnected F Disconnected G Input receiver channel parallel to input of Open Close H Input receiv...

Страница 5: ... obstruction during closing DL3 RED a Led which signals blockade of the gate the LED automatically switches off when the command Stop is activated RST Indicates a couple of Pin that short circuited for example by means of screwdriver allows RESET of the control box INPUTS OUTPUTS DEFINITIONS Input power supply from transformer 20V 10 Motors outputs 24V 100W the motor connected to the terminals 6 7...

Страница 6: ...roceeds the operation of automatic learning of the shutter movements and bringing to automation the closing time The automatic learning phase is deactivated PROGRAMMING The programming of the central unit requires the following steps Manual opening of the gate Program SW 8 ON the blinking unit will emit a steady light to inform the user that the programming procedure has been started Press the Ope...

Страница 7: ...f the semi automatic functioning is activated with SW 3 ON every Open Close command will cause the inversion of gate leaf movement both during the opening and closing phase 4 The Open Close command after the power supply is cut or reset by touching the two Pins marked as RST with the screwdriver point provokes first the complete opening of the gate and then the automatic closing up to the proper m...

Страница 8: ...Instructions 8 Rev 0 03 06 Stagnoli s r l Via Mantova Traversa 1 105 A B 25017 Lonato Bs Italia Tel 39 030 9139511 Fax 39 030 91380 www stagnoli com ...

Отзывы: