3.
Protection devices
The DDA4-1000 includes a protection component against
momentary over voltages. But continuous overvoltage, which is an
indicator for a faulty mains supply, causes overheating of this
component.
To prevent damage to the DDA4-1000 by overheating and then by
over voltage, there is a thermo-fuse witch cuts off the power supply.
If this happens, the temperature fuse must be replaced, either by us
or by an electrician.
In addition, the DDA4-1000 has a 5x20mm ceramic body cartridge
fuse, fast blow, 5Amp (with high breaking capacity 1500A)
The use of the cheaper glass tubes is not permitted (to low breaking
capacity).
4.
Displays (LEDs on board )
DMX
green
lit
= DMX512 valid
blink
= no or invalid DMX signal
SYS
yellow
blink
= System is running
C1 - 4
yellow
brightness proportional to output 1 to 4