Stafer 595.K.RS.00 Скачать руководство пользователя страница 2

ü

Incorrect installation can cause serious injuries. 

ü

Keep these instructions for future maintenance operations and the disposal of the product.

ü

All the product installation, connection, programming and maintenance operations must be carried out only by a qualified and skilled technician, who must 
comply with laws, provisions and local regulations, and the instructions provided herein.

ü

Wiring must comply with current CEI standards. In compliance with the provisions of Italian Ministerial Decree 37/2008, the final electrical system must be 
installed only by an electrician.

ü

Some applications require “man present” operation and can exclude the use of radio commands or require particular safety devices.

ü

To prevent potentially dangerous situations, regularly check the operating condition of the rolling shutter/awning.

01.1 SAFETY WARNINGS

01. WARNINGS. WARNING!

Importanti istruzioni di sicurezza!

ü

Read the technical specifications in paragraph “Technical Specifications” to evaluate the operating parameters of the product.

ü

Before installing the product, check compatibility with associated devices and accessories.

ü

The motor connected to the device must be of the “mechanical limit switch” type, without any electronic control; the motor must be of power adequate to the 
charge (check the rating plate data on the motor).

ü

Check that the package is intact and has not been damaged during transport.

ü

A heavy shock, falls, crushing and the use of unsuitable tools can cause the damage of the external or internal parts of the product.

ü

Do not pierce or tamper with the product in any way. Do not modify or replace parts without the Manufacturer's permission.

ü

Check that the location selected for product installation enables the blades to be exposed to the same wind to which the rolling shutter to be motorized is 
exposed.

ü

Check that the installation location is made of solid materials and can ensure a stable installation.

ü

Do not install the product near heat sources (such as chimneys, etc....).

ü

Adjust the control unit inclination so that blades are positioned horizontally.

ü

The wind detection blades must face downward. The blades must be free to rotate without obstruction.

ü

Check that the control unit is placed in a protected position from accidental impact with other objects (e.g. branches, etc.).

ü

The power cable must be positioned in such a way as to avoid contact with moving parts.

ü

Do not use abrasive or solvent products for cleaning the device; do not clean using water-jet or high-pressure cleaners.

ü

For your safety, do not work near the coiler while the motor is powered.

01.2 INSTALLATION WARNINGS

ü

The product is not intended to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they are supervised or given instructions about the product way of use by a person responsible for their safety.

ü

Check automation during operation and keep people at a safe distance, until operation ends.

ü

Do not allow children to play with the appliance or with the fixed control devices.

ü

Do not operate the rolling shutter when maintenance operations are being carried out (e.g. window cleaning, etc.). If the control device is automatic, 
disconnect the motor from the power line.

01.3 USE WARNINGS

This sensor does not protect shutters in case of strong and sudden wind gusts. 

In case of weather hazards of this type, make sure that shutters 

remain closed! Stafer S.p.A. declines all liability for damage incurred due to weather events not detected by the device.
Any other use beyond the field defined by Stafer S.p.A. is prohibited and involves, as well as the failure to comply with instructions provided in this guide, 
voidance of Stafer S.p.A.'s liability and warranty. The installer, after the installation of the product, must train the end user about the use of the automation and 
provide him with the user and maintenance manual.

WARNING!!

STAFER  uses  recyclable  packaging  materials.  Dispose  of  materials  in  proper 
containers, in compliance with laws in force in your location. 
If you are an installer and use a large number of motors, ask your dealer about receiving 
motors in “honeycomb pads”, an environmentally friendly choice that limits clutter and 
waste by reducing the amount of packaging materials.
This product may have substances that are polluting for the environment 
and dangerous for the health. At the end of the product life cycle, carefully 
comply with local waste disposal rules. It is strictly forbidden to dispose of 
the product in the domestic waste.

Let's protect the environment!

01 Warnings 

page 01

02 Assembly instructions 

page 02

03 Electrical connections 

page 02

04 Interfacing with home automation control units  

page 04

05 How to store the setting of the first remote control  

page 04

06 Store/delete additional remote controls  

page 05

07 WIND sensor  

page 05

08 SUN function  

page 06

09 Anemometric test function 

page 06

10 Operating logic of command buttons  

page 07

11 Automatic lowering function after wind alarm  

page 07

12 Anemometer check on awning status  

page 07

13 Anemometer reset to factory values  

page 08

14 Total reset to factory values  

page 08

Index

ü

  Power supply: 

120 or 230 Vac, 50/60 Hz

ü

 Dimensions: 

240 x 60 x H.111/133 mm

ü

 Weight: 

230 g

ü

 Operating temperature: 

from –20 to +55 °C

ü

 Protecnion degree 

IP 55

ü

 Wind threshold: 

from 5 to 35 km/h

ü

  Sun threshold: 

from 1 to 45 Klux

Technical specifications

Dear Customer, thank you for purchasing a Stafer S.p.A. product. This guide contains information about the use of the product. Before installing and using the 
product, please read this guide carefully and keep it for future reference. 595.K.RS.00 is a sun/wind sensor designed to operate tubular motors with mechanical 
limit switch powered by main voltage, and suitable to operate awnings, blinds or similar products. It can be controlled by buttons only, remote control only or 
both. 595.K.RS.00 allows operating the automatic retraction of awnings connected to the motor when the wind exceeds the set threshold, as well as their 
release when the intensity of sun exceeds the set threshold. These thresholds are set by the factory, but they can be adjusted according to the needs.

595.K.RS.00

01

It is advisable 

to avoid using radio systems in areas with strong interference

 (for example, near police stations, airports, ports, banks, etc.). 

Radio systems can be used where possible disturbances or malfunctioning of the transmitter or the receiver do not cause a risk factor, or if the risk 
factor is cancelled by suitable safety systems. The presence of radio devices operating on the same transmission frequency 

(433.42 MHz)

 can 

interfere with the radio receiver of the device and thus reduce the range of the system and limit the functionality of the entire system.

Notes on radio systems

Содержание 595.K.RS.00

Страница 1: ...www stafer com USER AND MAINTENANCE MANUAL Radio controlled sun wind anemometer for 1 or 2 motors ENG 595 K RS 00 recycled paper version 2 0 ...

Страница 2: ...does not protect shutters in case of strong and sudden wind gusts In case of weather hazards of this type make sure that shutters remain closed Stafer S p A declines all liability for damage incurred due to weather events not detected by the device Any other use beyond the field defined by Stafer S p A is prohibited and involves as well as the failure to comply with instructions provided in this g...

Страница 3: ...er line does not feed on electrical circuits to be used for lighting ü Always connect the motor to the grounding system yellow green ü The power line must be equipped with a magnetothermal or differential circuit breaker A category III overvoltage disconnection device must be fitted on the power supply line i e at a distance of at least 3 5 mm between the contacts ü The product does not provide fo...

Страница 4: ...OARD maneuver maneuver maneuver blue yellow green yellow green blue maneuver yellow green maneuver maneuver up down up down 3 15A fuse 3 15A fuse yellow green blue MAIN POWER SUPPLY L N maneuver maneuver down BUTTON 1 MECHANICAL MOTOR 1 blue ANEMOMETER TERMINAL BOARD Below is the combination of colored cables with the corresponding controls ...

Страница 5: ...etting storage 06 The second motor was automatically associated with the next channel e g if the first motor was on channel 3 the second motor will be combined with channel 4 If the motor movement does not correspond to the direction of the remote control button invert the wires of terminals 10 and 12 inside the anemometer Possibility to move 2 awnings simultaneously from a single 1 channel remote...

Страница 6: ...h 35 Km h Tab 01 Wind threshold Notes 1 The button must be briefly pressed approx 1 second between two pressings 2 The button must be briefly pressed approx 1 second between two pressings If you do not want to change the setting wait 15 seconds without pressing any button 3 If you try to set a wind threshold higher than 5 the value is rejected and completes 4 short up down movements 01 Bring the m...

Страница 7: ...ue 07 After 2 seconds the motor performs upward movements equal to the set value 08 Press MENU to exit the motor does not show anything USING THE REMOTE CONTROL Item 596 01 Bring the motor to the intermediate position 02 Press 3 times on PROG 03 Press twice on UP and 3 times on DOWN 04 Press STOP once The motor shows up down 05 Press UP once The motor shows the current value by performing 1 to 5 m...

Страница 8: ...e intermediate position 02 Press 3 times on PROG The motor shows up down 03 Press twice on UP and 4 times on DOWN 04 Press STOP once The motor shows the current setting Once UP activate Once DOWN deactivate 05 Within 5 seconds press the UP or DOWN button according to the function you wish to set 06 After 2 seconds the motor replicates the command received with an UP or DOWN movement 07 Press PROG ...

Страница 9: ...up down 07 Press PROG 3 times to exit the motor does not show anything USING THE REMOTE CONTROL Item 595 USING THE REMOTE CONTROL Item 596 01 Bring the motor to the intermediate position 02 Remove and restore power 03 Press UP 3 times and DOWN 3 times The motor shows up down 04 Press twice on UP and 4 times on DOWN The motor shows the current setting Once UP activate Once DOWN deactivate 05 Within...

Отзывы: