background image

ACE Stoßdämpfer GmbH  ·  Postfach 1510  ·  D-40740 Langenfeld  ·  T +49 (0)2173 - 9226-10 (Technik -20)  ·  F +49 (0)2173 - 9226-19  ·  [email protected]  ·  www.ace-ace.com

Stand 03.2021

ACE Stoßdämpfer GmbH  ·  www.ace-ace.com

21_22_0019 Issue 05.2022

2

α

WARNING

If ACE rotary dampers are used where a failure of the 

product could lead to personal injuries and/or material 

damage, additional safety elements must be implemented.
Free-moving masses, such as lids, flaps, covers etc., can 

lead to injuries by crushing during installation of the rotary 

dampers. 

Secure moving flap/mass against falling down!

Intended use

ACE rotary dampers ensure the controlled opening and closing of 

small covers, compartments and drawers. They can brake directly 

at the pivot point or linearly via rack and pinion to attain a smooth 

and quiet movement. Sensitive components are preserved. The 

harmoniously gentle process increases the quality and value of 

the product. 

Description and function

On the adjustable rotary dampers with a partial rotation angle 

the fluid is pressed from one chamber to another by the rotor 

movement. The damping torque is determined by the viscosity of 

the fluid or the dimensioning of the damping orifice or metering 

orifice. During each reverse movement of the unilateral decelerat-

ing versions there is a certain return damping torque that depends 

on the size. 
ACE rotary dampers are maintenance-free and ready-to-install. 
The damping direction can be rotating right/left or two-sided. The 

outer bodies are made from zinc die-cast. The dampers can be 

mounted directly at the pivot point.

Safety information

Delivery and storage

-   After delivery please check the rotary dampers for any damage.
-   The rotary damper can become damaged if it falls. Carefully 

remove rotary damper from the packaging.

-   Rotary dampers can generally be stored in any position.
-  Storage in the original packaging is preferred.
-  Always store rotary dampers dry.
-  The recommended maximum storage time is two years.
-   Storage of rotary dampers is permissible at -20 °C to +70 °C.

Maintenance and care

Regularly check the rotary damper for oil loss and external dam-

age. Rotary dampers are machine elements that are subject to 

continuous wear. Increased service life results in reduced braking 

effect. If this is no longer sufficient, the rotary dampers must be 

replaced or exchanged as appropriate.

Disassembly and disposal

Take account of environmental protection (recovery of problematic 

substances) during disposal of the rotary dampers. The rotary 

dampers are filled with silicone oil. The corresponding data sheet 

is available on request. By design, the silicone oil cannot be 

refilled. The rotary dampers cannot be repaired. Faulty brakes can 

be sent to our service department for determination of the cause 

of failure.

Calculation steps

1.   Calculate torque for unfavourable angle  

(see example on left: 0°).

2.  Determine angular speed.
 3.  Choose a suitable rotary damper for the calculated torque.
 4.   With the aid of the damper performance curve, check whether 

the rpm matches the desired speed.

 5.  If the rpm is too high – choose a higher torque.
6.  If the rpm is too low – choose a lower torque.

Torque

M = L / 2 · m · g · cos α

(L / 2 = centre of gravity)

m

  Mass in kg [1 kg = 9.81 N]

L

  Flap length in cm

n

  Speed in rpm

Calculation example: Damping of a flap

In order to select a suitable rotary damper for the calculation 

example shown, the length and the weight or centre of gravity of 

the flap must be specified. Once the max. torque value with an 

unfavourable angle of the flap has been determined, a suitable 

brake is selected.

General instructions

This manual is for the disruption-free use of the product 

types listed on page 1; its compliance is a prerequisite 

for the fulfilment of any warranty claims.
Therefore, make sure to read this manual before use.
Always maintain the limits specified in the performance 

table. Take into account the predominant environmental 

conditions and restrictions. Note the regulations of 

the trade association, TÜV or corresponding national, 

international and European regulations. Installation and 

commissioning only according to mounting instructions.

Calculation and design

In order to ensure an optimum fault-free and durable function of the rotary dampers, they must be correctly dimensioned and designed. The following parameters 

must be known and used in the calculation.
- Temperature
-  Damping torque
- Speed
-  Cycle number
Should you have any further questions about the use of rotary dampers, please contact one of our ACE technicians.  

For free calculation service, phone: +49 (0)2173 - 9226-20.

Rotary Damper FYT-LA3 and FYN-LA3 (partial rotation angle, adjustable)

Manual

Отзывы: