STABILUS ACE MC33-V4A Скачать руководство пользователя страница 5

ACE Stoßdämpfer GmbH  ·  Postfach 1510  ·  D-40740 Langenfeld  ·  T +49 (0)2173 - 9226-10 (Technik -20)  ·  F +49 (0)2173 - 9226-19  ·  [email protected]  ·  www.ace-ace.com

Stand 03.2021

ACE Stoßdämpfer GmbH  ·  www.ace-ace.com

21_22_0019 Issue 05.2022

5

M

L2

Stroke

Ø 

d1

Ø 

d2

A max.

L1

Installation instructions

Before installation and use check whether the identification 

number on the damper or on the packaging matches the respective 

designation on the delivery note. Industrial shock absorbers are 

maintenance-free and ready to install.

Operating temperature range:

 -12 °C to 66 °C

Mounting:

 As required but always in such a way that the entire 

damper stroke is used. The dampers must always be mounted in 

such a way that the forces are introduced centrally over the piston 

rod. The maximum permissible side load angle (see table) must 

not be exceeded. If there is a side load angle, it generally leads 

to a reduction in service life. In the case of maximum permissible 

values being exceeded a side load adapter must be used.

Self-compensating:

 The MC range of shock absorbers is 

self-compensating. In a selectable range according to a table, the 

different effects of power, weight, temperature and speed balance 

out independently. The shock absorbers are divided into five 

hardness ranges (me min. to me max.) as standard. The grading 

ranges from -0 (very soft) to -4 (very hard).

WARNING

Temperature effect: The W

4

 and me values given in the 

performance table (see manual or catalogue) are valid 

for room temperature. Deviating values apply to higher 

temperatures.
During installation of the dampers moving masses can 

lead to injuries due to inadvertent starting. Secure moving 

masses against inadvertent moving.
The dampers may be unsuitable for use and have an 

insufficient damping effect. Check the specific suitability 

of the dampers before installation.
If operated outside of the operating temperature range, 

the damper can lose its function. Operating temperature 

range must be maintained. Do not paint dampers due to 

heat emission.
Fluids, gases and dirt particles in the surrounding area can 

attack or destroy the seal system of the damper and cause 

it to fail. Protect or encapsulate piston rod and seal system 

from external materials in the surrounding area. 
Damage to the piston rod surface can destroy the seal 

system. Do not grease, oil piston rod etc. and protect 

against dirt particles.
The piston rod can be torn from the damper. Do not load 

the piston rod with tensile stress.
Damper can tear off upon impact. Always lay out the 

connection structure in such a way that the maximum 

occurring forces can be absorbed with sufficient safety. 

The maximum reacting forces listed in the calculation range 

may deviate from the actually occurring reacting forces, as 

these are based on theoretical values.

Commissioning

-  After installation, start a test run of the moving mass at reduced 

operating speed to begin with. 

 

During the test run

-  Gradually accelerate the load capacity up to the subsequent 

operating speed. You can find this in the calculation for your 

application. In the correct final setting, the piston rod of the 

shock absorber reaches the end position (positive stop) without 

a hard stop.

Mounting accessories

Information on the corresponding mounting accessories can be 

found on the following pages.

Dimensions

TYPES

Stroke

mm

A max.

mm

d1

mm

d2

mm

L1

mm

L2

mm

MC4525EUM-V4A

23.1

164.5

42

42

19.4

95

M45x1.5

MC4550EUM-V4A

48.5

214.4

42

42

19.4

120

M45x1.5

MC4575EUM-V4A

73.9

265.4

42

42

19.4

145

M45x1.5

Performance data

Max. Energy Capacity

Effective Weight

TYPES

W

3

Nm/cycle

W

4

Nm/h

1

 me min.

kg

1

 me max.

kg

Hardness  Return Force min.

N

Return Force max.

N

Return Time

s

2

 Side Load Angle max. 

°

Weight

kg

MC4525EUM-0-V4A

370

107,000

7

27

-0

70

100

0.03

4

1.14

MC4525EUM-1-V4A

370

107,000

20

90

-1

70

100

0.03

4

2.09

MC4525EUM-2-V4A

370

107,000

80

310

-2

70

100

0.03

4

1.14

MC4525EUM-3-V4A

370

107,000

260

1,050

-3

70

100

0.03

4

1.31

MC4525EUM-4-V4A

370

107,000

890

3,540

-4

70

100

0.03

4

1.31

MC4550EUM-0-V4A

740

112,000

13

54

-0

70

145

0.08

3

1.41

MC4550EUM-1-V4A

740

112,000

45

180

-1

70

145

0.08

3

1.36

MC4550EUM-2-V4A

740

112,000

150

620

-2

70

145

0.08

3

1.37

MC4550EUM-3-V4A

740

112,000

520

2,090

-3

70

145

0.08

3

1.41

MC4550EUM-4-V4A

740

112,000

1,800

7,100

-4

70

145

0.08

3

1.39

MC4575EUM-0-V4A

1,130

146,000

20

80

-0

50

180

0.11

2

1.59

MC4575EUM-1-V4A

1,130

146,000

70

270

-1

50

180

0.11

2

1.59

MC4575EUM-2-V4A

1,130

146,000

230

930

-2

50

180

0.11

2

1.50

MC4575EUM-3-V4A

1,130

146,000

790

3,140

-3

50

180

0.11

2

1.59

MC4575EUM-4-V4A

1,130

146,000

2,650

10,600

-4

50

180

0.11

2

1.59

1

 It is permissible to exceed the stated energy in emergency stop situations. In the event of such a case, please contact ACE. 

2

 If side load angle is higher contact ACE.

Packaging disposal

Please dispose of the transportation packaging in an environ-

mentally-friendly manner. Recycling packaging materials saves 

raw materials and reduces waste. The packaging materials do not 

contain any prohibited materials.

Model type prefix

Standard types

MC: self-contained with return spring, self-compensating

Special types

MCA: not self-contained, without spring. Use only with external air/oil tank. 

MCS: not self-contained, with spring. Use only with external air/oil tank. 

MCN: self-contained, without spring

Mounting instructions and mounting accessories

Industrial Shock Absorbers MC45-V4A (self-compensating, stainless steel)

Содержание ACE MC33-V4A

Страница 1: ...MC45EUM V4A MC64EUM V4A MC33 V4A to MC64 V4A Industrial Shock Absorbers The best corrosion protection Self compensating stainless steel Energy capacity from 170 Nm cycle to 3 730 Nm cycle 23 1 mm to...

Страница 2: ...can generally be stored in any position Storage in the original packaging is preferred Always store shock absorbers in a dry place in order to avoid oxidation The recommended maximum storage time is t...

Страница 3: ...nsile stress Damper can tear off upon impact Always lay out the connection structure in such a way that the maximum occurring forces can be absorbed with sufficient safety The maximum reacting forces...

Страница 4: ...accessories are not included If you have any questions please phone 49 0 2173 9226 20 for free advice When using accessory parts and mounting elements also note the Mounting types QF33 V4A Square Flan...

Страница 5: ...ficient safety The maximum reacting forces listed in the calculation range may deviate from the actually occurring reacting forces as these are based on theoretical values Commissioning After installa...

Страница 6: ...accessories are not included If you have any questions please phone 49 0 2173 9226 20 for free advice When using accessory parts and mounting elements also note the mounting instructions for accessori...

Страница 7: ...ess Damper can tear off upon impact Always lay out the connection structure in such a way that the maximum occurring forces can be absorbed with sufficient safety The maximum reacting forces listed in...

Страница 8: ...cessories are not included If you have any questions please phone 49 0 2173 9226 20 for free advice When using accessory parts and mounting elements also note the mounting instructions for accessories...

Страница 9: ...acturing factory apply to parts not manufactured and processed by the vendor which can be viewed by the orderer at the vendor at any time Construction and installation parts are delivered according to...