Measuring modes
Accuracy:
Automatic precision adjustment:
Only operates in conjunction with a laser transmitter with the appropriate features.
The precision adjustment function can be used,
for example, to align laser lines exactly with
the required reference lines, edges,or compo-
nents. The laser transmitter continues to
rotate automatically until the laser line is
precisely “in line“ with the receiver. Using the
remote operation function the laser transmitter
can be aligned with the REC 410 Line RF
within the range ± 5°*. The receiver must be
registered with the laser for this to be possible
(
» Registration
). It is only sensible to use this function if the receiver is
positioned on a flat surface*.
* particularly in conjunction with LA180L
1. Align the laser approximately with the receiver.
2. Precision adjustment can be undertaken in two different operating modes.
A. Semi-automatic
Use the arrow buttons (e) for precision adjustment in the required direction.
The laser transmitter will rotate in a single movement in the direction indicated.
B. Fully automatic
The laser transmitter initially rotates to the limit of the operating range (± 5°)
and then moves in the opposite direction until it reaches the position where
the maximum strength of laser signal is received.
B1. Simple mode
The laser transmitter will rotate in a single move-
ment until it reaches the position where the
maximum strength of laser signal is received.
B2. Continuous mode
Continuous, independent rotation/ tracking of the
receiver by the laser beam.
≤ 40 m/131 ft
> 2
sec
>2
sec