Stabila REC 410 Line RF Скачать руководство пользователя страница 3

en

Getting started

Press the ON/OFF button (a). An audio signal, a brief flash from the display 

and the LEDs confirm that the receiver is switched on. Press the ON/OFF but-

ton (a) quickly once to switch the instrument off. If the instrument is not used, 

it will automatically switch itself off after 30 minutes.

Display

9 display steps indicate the divergence from the 

centre of the laser line. The central bar indica-

tes the “in line” position of the REC 410 Line RF. 

The arrow increases in size as the distance from 

the “in line” position increases.

Audio signals

Setting the volume

The volume is increased/decreased by repeatedly pressing the button (b):

Loud (1)

out (2)

 or 

soft (3)

. If the instrument is set to “silent” only a short 

beep is emitted when the laser beam is received.

REC 410 

Line RF

65 mm

2.50 inc

h

REC 410 

Line RF

REC 410 

Line RF

(1)

(2)

(3)

Содержание REC 410 Line RF

Страница 1: ...REC 410 Line RF en REC 410 Line RF Operating instructions...

Страница 2: ...ions we should be pleased to provide advice over the telephone at any time on the following telephone number 49 6346 309 0 Main components a ON OFF b Volume c Accuracy d Automatic precision adjustment...

Страница 3: ...isplay steps indicate the divergence from the centre of the laser line The central bar indica tes the in line position of the REC 410 Line RF The arrow increases in size as the distance from the in li...

Страница 4: ...ioned on a flat surface particularly in conjunction with LA180L 1 Align the laser approximately with the receiver 2 Precision adjustment can be undertaken in two different operating modes A Semi autom...

Страница 5: ...attery display Open the battery compartment cover m in the direction of the arrow Insert new batteries as indicated by the symbols in the battery compartment 3 x 1 5V miniature alkaline batteries size...

Страница 6: ...d ensure other users do also Periodically carry out test measure ments particularly after the detector has been subjected to abnormal use and before and after important measurements Positioning and ad...

Страница 7: ...All users must follow the safety directions given by the manufacturer and the directions of the person responsible for the product Electromagnetic Compatibility EMC The term Electromagnetic Compatabil...

Страница 8: ...sources or for any autonomous changes made to the unit by the purchaser or a third party Also no claims under guarantee are accepted for natural wear and tear or any small faults that do not significa...

Страница 9: ...his equipment does cause harmful interference to radio or tele vision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by...

Страница 10: ...i hele verden Takuuilmoituksen t ydennys Takuu on voimassa maailmanlaajuisesti Supplement til garantierkl ring Garantien g lder internationalt Komplettering till garantif rklaring Garantin g ller i he...

Страница 11: ...O Box 13 40 D 76851 Annweiler Landauer Str 45 D 76855 Annweiler Tel 49 63 46 309 0 Fax 49 63 46 309 480 e mail info stabila de www stabila com USA Canada STABILA Inc 332 Industrial Drive South Elgin...

Отзывы: