Replacing the batteries
Full: Batteries OK
Batteries weak
Slide the battery cover (7) in the direction of the arrow and insert new batteries
in accordance with the symbols in the battery compartment.
Remove the batteries if the unit will not be used for a long period !
Alkaline
AA, LR6,
Mignon
2x 1,5V
+
+
Setting the accuracy
The receiver always starts with the accuracy setting “fine”.
Repeated, brief pressing of the “Accuracy” button (2) to select the accuracy:
“fine” = ± 1.0 mm ( ± 1/32 in.) and “coarse” = ± 3.0 mm ( ± 1/8 in.).
2
1x
± 3,0 mm ±1/8 in.
1
1x
± 1,0 mm ±1/32 in.