Checking the horizontal laser line level

 

Be sure to adhere as closely as possible to the orientation 

of the unit as shown.
1. Place the LAR 300 on a horizontal surface or on a tripod 

at a distance of 5 or 10 m (25 or 50 ft) from a wall, with 

the operator panel towards the wall.

2. Switch the laser unit on (button (3)) and wait until it has 

automatically levelled itself.

3. Mark the centre of the visible laser line on the wall – 

measurement 1 (point 1).  A receiver can also be used. 

4. Rotate the entire laser unit through 90° without alter-

ing the height of the laser

 

(i.e. do not change the tripod 

height). Allow the unit to

 

level itself again.

5. Mark the centre of the laser line on the wall (point 2).
6. Repeat steps 4 and 5 twice to obtain points 3 and 4.

If the differences between the four control points are less 

than 1 mm distance of 5 m (1/16” at 25 ft) or less than 2 mm 

for a distance of 10 m (1/8” at 50 ft), the unit is within its 

permitted tolerance of ± 0.1 mm/m (± 18” over 100ft). Here 

points 1 and 3 correspond to the unit’s x-axis and points 2 

and 4 to its y-axis.

12.2 Horizontal check

The LAR 300 rotation laser from STABILA is designed for 

use on building sites and is perfectly adjusted before 

leaving our premises. As with all precision instruments, 

you should regularly check the calibration accuracy of 

the unit. Always check the unit before you start work, 

especially if it has been exposed to heavy vibrations.

Horizontal check

12.1 Checking accuracy

5 m / 25 ft

10 m 50 ft

1

1

2

Y

1

1

X

X

Y

2

3

1

2

2

1

X

X

3

4
3

1
2

5 m

 

≤ 1 mm

10 m

 

≤ 2 mm

Maximum 

permissible 

difference:

3

2

1

Y

Y

4

25 ft

 

≤ 1/16”

50 ft

 

≤ 1/8”

Содержание LAR 300

Страница 1: ...Operating instructions...

Страница 2: ...ry insertion replacement 6 6 Commissioning 7 7 Tilt function 8 8 1 Automatic operation with tilt function 9 8 2 Automatic operation with relevelling 10 9 1 Manual operation with tilt function 11 9 2 M...

Страница 3: ...sealed enclosure IP 65 for use on build ing sites It is self levelling within a range of 5 The laser beam can be picked up using a receiver even where it can no longer be discerned with the naked eye...

Страница 4: ...lable for our laser units are not safety eyewear their function is to improve the visibility of the laser beam Do not aim the laser beam directly at people Avoid dazzling other people with the unit Ke...

Страница 5: ...Battery low 7 Red LED Overtemperature 8 Blue LED Laser x axis display TILT Manual 9 Green LED Laser y axis display TILT Manual 10 Battery compartment lid 11 5 8 tripod socket 12 Retaining bracket 13...

Страница 6: ...rechargeable batteries can also be used LED indicator Yellow LED 6 Battery capacity low Insert new battery Used batteries should be disposed of at appropriate collection points Do not dispose of in h...

Страница 7: ...or rotate Once levelling is complete the beam stays on constantly and begins to rotate Fine adjustments can still be made within the first 30 sec onds These 30 seconds are indicated by a slow flashing...

Страница 8: ...does not go unnoticed The white LED 5 lights up steadily when the tilt function is active If any event occurs that could result in the laser unit being deflected from its exact alignment and setting...

Страница 9: ...e Fine adjustments can still be made within the first 30 seconds These 30 seconds are indicated by a slow flashing of the white LED 5 When the tilt function is active the white LED 5 lights up steadil...

Страница 10: ...o deacti vate the tilt function The white LED 5 flashes The laser beam begins to rotate once the unit has levelled itself When incidents occur that cause misalignment the laser beam ceases to rotate T...

Страница 11: ...lights up after flashing briefly The blue 8 and green 9 LEDs light up steadily The laser beam rotates Fine adjustments can still be made within the first 30 seconds The laser plane can be set up by d...

Страница 12: ...ely by hand The unit does not level itself Place the laser unit in the working position Press button 3 twice once to switch on once to deactivate tilt function Press button 4 once change over to activ...

Страница 13: ...to the ceiling To transfer a plumb line from a floor marking to the ceiling the laser unit is aligned exactly with the cross mark with the 4 marking points 14 The point of intersection of the cross ma...

Страница 14: ...ion replacement The temperature inside the unit is above 50 C To prevent overheating the laser diode has been switched off Operating in manual mode Manual operation Manual operation with tilt function...

Страница 15: ...t steps 4 and 5 twice to obtain points 3 and 4 If the differences between the four control points are less than 1 mm distance of 5 m 1 16 at 25 ft or less than 2 mm for a distance of 10 m 1 8 at 50 ft...

Страница 16: ...FR parts 1040 10 and 1040 11 Self levelling range approx 5 Levelling accuracy 0 1 mm m 1 8 over 50 ft Batteries 2 x 1 5 V alkaline size mono D LR20 Battery life approx 80 hours alkaline Operating temp...

Страница 17: ...alia Asia Africa STABILA Inc 332 Industrial Drive South Elgin IL 60177 800 869 7460 custservice Stabila com STABILA Messger te Gustav Ullrich GmbH P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 768...

Отзывы: