Pump

Body

From

Well

Dirt and Scale Plug Pump and Pipes!

Use New Pipe for Best Results.

Clean Flow!

No Sags

Sags Allow Air Pockets

If Air Pockets Form, Water Won’t Flow.

Keep Pipe Straight and Angled up to Pump.

Figure 1: No Dirt or Scale in Suction
Pipe

Figure 2: Foot Valve Must Work Freely

Figure 3: No Air Pockets in Suction
Pipe

Installation

4

1102 0

No Air Leaks

in Suction Pipe.

Pipe Joint

Compound Will

Damage Plastic.

If Air Flows

Water Won’t

Use Teflon Tape.

Figure 4: Suction Pipe Must Not Leak

BEFORE YOU INSTALL YOUR PUMP

NOTE:

For proper performance, pump MUST be matched to ejector and to

well depth. Use shallow well installation for wells up to 25 ft depth to
water and deep well ejector for depths up to 130 ft. 

Step 1. Long runs and many fittings increase friction and reduce flow.

Locate pump as close to well as possible: use as few elbows and fit-
tings as possible.

Step 2. Be sure well is clear of sand. Sand will plug the pump and void the

warranty.

Step 3. Protect pump and all piping from freezing. Freezing will split pipe,

damage pump and void the warranty. Check locally for frost protec-
tion requirements (usually pipe must by 12” below frost line and
pump must be insulated).

Step 4. Be sure all pipes and foot valve are clean and in good shape.

Step 5. No air pockets in suction pipe.

Step 6. No leaks in suction pipe. Use Teflon tape or Plasto-Joint Stik to seal

pipe joints.

Step 7. Match pump to well.

IMPORTANT: Flow into well must at least equal flow out through
pump! 

Step 8. Unions installed near pump and well will aid in servicing. Leave

room to use wrenches.

Step 9. Plug 1” drive port when installing on shallow well.

SHALLOW WELL/CENTRIFUGAL INSTALLATION

No ejector is used in this case, plug the smaller of the two inlet ports, using
the larger for the suction pipe. Refer to Figure 6 for installation tips.
Maximum depth to water for shallow well/centrifugal operation is 25 feet.

NOTE:

To avoid pump overloading and motor failure, install a flow control

valve at the discharge to limit flow to 20 gallons per minute.

Well
Casing

Foot
Valve &
Strainer

Deep well is more
than 25' (7.6M)
to water with
pump running.

Figure 5: Double Pipe Deep Well

Be sure 
entire 
well 
point is
below 
water.

Drive
Coupling

Drive
Point

Check
Valve

1" NPT 
Plug

Well
Casing

1" NPT 
Plug

Foot
Valve &
Strainer

Shallow well is less
than 25' (7.6M)
to water with
pump running.

822 0697

Figure 6: Cased Shallow Well 
and Drive Point Shallow Well

Содержание MSC-6

Страница 1: ...umps 20 100 80 60 40 2001 Sta Rite Industries Inc PRINTED IN U S A S757 1 Rev 10 31 01 293 Wright Street Delavan WI 53115 MS Series Installation Operation Parts For further operating installation or m...

Страница 2: ...GENERAL SAFETY Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before hand...

Страница 3: ...duty is to repair or replace defective products at Sta Rite s choice Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty service through the instal...

Страница 4: ...equirements usually pipe must by 12 below frost line and pump must be insulated Step 4 Be sure all pipes and foot valve are clean and in good shape Step 5 No air pockets in suction pipe Step 6 No leak...

Страница 5: ...at least 10 to 20 feet below the lowest water level with pump running if possi ble but always at least five feet from the bottom of the well Step 8 Tighten all hose clamps securely on plastic pipe Use...

Страница 6: ...e well see Figure 8 Step 4 To properly seat the cup seals after the ejector is correctly posi tioned move the assembly up and down slightly Water pressure in the casing will then soak the cup seals se...

Страница 7: ...pump and to AVC on tank See installation instructions provid ed with tank and AVC for details PRECHARGED TANK CONNECTION When a precharged tank is used no AVC is necessary See Figure 10 for typical p...

Страница 8: ...oltage motor Connect power supply as shown for your type of switch and your supply voltage Pull plug straight out from terminal board 1 1 2 2 Plug in again with arrow on plug pointing to 115 Volts A L...

Страница 9: ...ure 12 The ground wire must be a solid copper wire at least as large as the power sup ply wires Step 2 There must be a solid metal connection between the pressure switch and the motor for motor ground...

Страница 10: ...more as ejector and pump prime IF NO PRESSURE OR NO WATER REPEAT Step No 1 above two or three times to remove entrapped air from the suction pipes Step 3 If after priming pump several times no water...

Страница 11: ...In this case operate pump with regulator valve open HOW TO HANDLE A GASEOUS WELL In some areas well water contains gases which must be allowed to escape before the water is used To deliver gas free w...

Страница 12: ...a small screwdriver or thin bladed chisel in between the intermediate volute and the pump adapter in two or three places around the pump to separate the castings Figure 20 Do not mar the sealing surfa...

Страница 13: ...e up with the water passages in the volutes Step 9 Install the intermediate volute aligning it with the mark made before disassembly Use the long cap screws to check this align ment It cannot be stres...

Страница 14: ...k valve or foot valve Pipes are frozen Thaw pipes Bury pipes below frost line Heat pit or pump house Foot valve and or strainer are Raise foot valve and or strainer above bottom of water source buried...

Страница 15: ...Lg 2 U30 75ZP U30 75ZP U30 75ZP U30 75ZP U30 75ZP 11 Shaft Key OH SG 2 U65 15SS U65 15SS U65 15SS U65 15SS 3 U65 15SS 3 12 Shaft Seal 6 Series OH SG 1 U109 99 U109 99 U109 99 U109 99 U109 99 12 Shaft...

Страница 16: ...lug on flange with locating lug on base volute Item 1 Remove paper backing form gasket before applying Item 2 Align locating lug on flange with locating lug on base volute 376 1293 1 1A 2A 2B 2C 2D 4...

Отзывы: